Summer thermal discomfort in substandard housing with openable windows in Hong Kong

被引:3
|
作者
Cheung, Pui Kwan [1 ]
Jim, C. Y. [1 ]
机构
[1] Educ Univ Hong Kong, Dept Social Sci, Tai Po, Lo Ping Rd, Hong Kong, Peoples R China
关键词
NATURALLY VENTILATED BUILDINGS; HEAT-RELATED ILLNESS; INDOOR AIR-QUALITY; COMFORT; PERFORMANCE; DESIGN; ENVIRONMENTS; TEMPERATURE; INSULATION; CLIMATE;
D O I
10.1080/23744731.2020.1855934
中图分类号
O414.1 [热力学];
学科分类号
摘要
The sub-divided unit (SDU) is the major type of substandard housing in Hong Kong. This study monitored the microclimatic conditions in eight SDUs for 24 h in summer. The mean CO2 concentration (1012 mg/m(3)) under natural ventilation was much higher than the outdoor level (similar to 410 mg/m(3)), suggesting that ventilation was ineffective in most SDUs. The mean predicted mean vote (PMV) was 1.7 (warm), corresponding to 75% predicted percentage dissatisfied (PPD). None of the SDUs was thermally acceptable (PPD < 20%) at any time in the monitoring period. If the adaptive thermal comfort standard was considered, the acceptable temperature range would be between 23.4 degrees C and 30.4 degrees C in operative temperature and the thermally acceptable time would be 47%. Larger openable window size, larger external wall area and poor ventilation significantly contributed to higher maximum indoor air temperature.
引用
收藏
页码:462 / 476
页数:15
相关论文
共 50 条
  • [41] PRECAST TO LAST - HONG KONG PUBLIC HOUSING EXPERIENCE
    Lam, Sze Chuen
    Chung, Kwok Chuen
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON TALL BUILDINGS, 2010, : 513 - 518
  • [42] Housing, home ownership and social change in Hong Kong
    La Grange, A
    [J]. URBAN STUDIES, 2001, 38 (01) : 219 - 220
  • [43] Housing Welfare, Personal Responsibility, and Morale in Hong Kong
    Chau-kiu Cheung
    [J]. Social Indicators Research, 2024, 171 : 905 - 919
  • [44] The Transferability of Hong Kong's Public Housing Policy
    Chiu, Rebecca
    [J]. INTERNATIONAL JOURNAL OF HOUSING POLICY, 2010, 10 (03): : 301 - 323
  • [45] Modeling and simulation of public housing construction in Hong Kong
    Shi, JJ
    Zeng, SX
    Tam, CM
    [J]. 1998 WINTER SIMULATION CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 1305 - 1310
  • [46] Air quality impacts of open-plan cooking in tiny substandard homes in Hong Kong
    Pui Kwan Cheung
    C. Y. Jim
    Chun To Siu
    [J]. Air Quality, Atmosphere & Health, 2019, 12 : 865 - 878
  • [47] Air quality impacts of open-plan cooking in tiny substandard homes in Hong Kong
    Cheung, Pui Kwan
    Jim, C. Y.
    Siu, Chun To
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2019, 12 (07): : 865 - 878
  • [48] A study of passenger discomfort measures at the Hong Kong Mass Transit Railway system
    Lam, WHK
    Cheung, CY
    Poon, YF
    [J]. JOURNAL OF ADVANCED TRANSPORTATION, 1999, 33 (03) : 389 - 399
  • [49] IMPACT OF CLIMATE ON SUMMER RESIDENTIAL ELECTRICITY CONSUMPTION IN HONG KONG
    Yuk Yee Yan Department of Geography Hong Kong Baptist University Kowloon Tong
    [J]. Journal of Geographical Sciences, 1997, (04) : 44 - 50
  • [50] The 2014 summer coral bleaching event in subtropical Hong Kong
    Xie, James Y.
    Lau, Dickey C. C.
    Kei, Keith
    Yu, Vriko P. F.
    Chow, Wing-Kuen
    Qiu, Jian-Wen