Lower-Extremity Electromyography Measures During Walking With Ankle-Destabilization Devices

被引:0
|
作者
Donovan, Luke [1 ]
Hart, Joseph M. [1 ]
Hertel, Jay [1 ]
机构
[1] Univ Virginia, Kinesiol Program, Charlottesville, VA 22903 USA
关键词
chronic ankle instability; gait; rehabilitation; FUNCTIONAL INSTABILITY; PLANTAR PRESSURE; POSTURAL CONTROL; MUSCLE STRENGTH; DEFICITS; SPRAINS; JOINT; INDIVIDUALS; KINEMATICS; INJURIES;
D O I
10.1123/JSR.2013-0021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Ankle-destabilization devices are rehabilitation tools that may improve neuromuscular control by increasing lower-extremity muscle activation. Their effects should be tested in healthy individuals before being implemented in rehabilitation programs. Objective: To compare EMG activation of lower-extremity muscles during walking while wearing 2 different ankle-destabilization devices. Design: Crossover. Setting: Laboratory. Participants: 15 healthy young adults (5 men, 10 women). Intervention: Surface EMG activity was recorded from the anterior tibialis, peroneus longus, lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius as subjects walked on a treadmill shod, with an ankle-destabilization boot (ADB), and an ankle-destabilization sandal (ADS). Main Outcome Measures: Normalized amplitudes 100 ms before and 200 ms after initial heel contact, time of onset activation relative to initial contact, and percent of activation time across the stride cycle were calculated for each muscle in each condition. Results: The precontact amplitudes of the peroneus longus and lateral gastrocnemius and the postcontact amplitudes of the lateral gastrocnemius were significantly greater in the ADB and ADS conditions. In the ADB condition, the rectus femoris and biceps femoris postcontact amplitudes were significantly greater than shod. The peroneus longus and lateral gastrocnemius were activated significantly earlier, and the anterior tibialis, lateral gastrocnemius, and rectus femoris were activated significantly longer across the stride cycle in the ADB and the ADS conditions. In addition, the peroneus longus was activated significantly longer in the ADB condition when compared with shod. Conclusions: Both ankle-destabilization devices caused an alteration in muscle activity during walking, which may be favorable to an injured patient. Therefore, implementing these devices in rehabilitation programs may be beneficial to improving neuromuscular control.
引用
收藏
页码:134 / 144
页数:11
相关论文
共 50 条
  • [31] 3-DIMENSIONAL LOWER-EXTREMITY JOINT FORCES AND TORQUES IN WALKING
    EKEN, MS
    DONATH, M
    [J]. JOURNAL OF BIOMECHANICS, 1984, 17 (11) : 875 - 875
  • [32] Effects of Long and Short Ankle Destabilization Devices on Muscular Activity while Walking
    Xie, Di
    Urabe, Yukio
    Yamanaka, Yuki
    Okuma, Ryo
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (04) : 651 - 653
  • [33] Delay in improvement of ankle-arm index and ankle waveforms after lower-extremity revascularization
    Tripathi, S
    Farid, A
    Deshmukh, N
    [J]. MILITARY MEDICINE, 1997, 162 (04) : 301 - 303
  • [34] Lower-extremity Biomechanics During A Drop-vertical Jump In Chronic Ankle Instability And Healthy Controls
    Herb, Christopher C.
    Grossman, Kaitlyn
    Feger, Mark
    Donovan, Luke
    Hertel, Jay
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 724 - 724
  • [35] Altered Lower Extremity Joint Energetic Patterns in Patients with Chronic Ankle Instability during Walking
    Fuhriman, Trevor
    Kim, Hyunsoo
    Son, S. Jun
    Roush, Jake
    Seeley, Matthew K.
    Hopkins, J. Ty
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 745 - 745
  • [36] Lower-Extremity Kinematics During Ankle Inversion Perturbations: A Novel Experimental Protocol That Simulates an Unexpected Lateral Ankle Sprain Mechanism
    Simpson, Jeffrey D.
    Stewart, Ethan M.
    Mosby, Anastasia M.
    Macias, David M.
    Chander, Harish
    Knight, Adam C.
    [J]. JOURNAL OF SPORT REHABILITATION, 2019, 28 (06) : 593 - 600
  • [37] Electromyography-controlled lower extremity exoskeleton to provide wearers flexibility in walking
    Chen, Weihai
    Lyu, Mingxing
    Ding, Xilun
    Wang, Jianhua
    Zhang, Jianbin
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79
  • [38] Lower-extremity function for driving an automobile after operative treatment of ankle fracture
    Egol, KA
    Sheikhazadeh, A
    Mogatederi, S
    Barnett, A
    Koval, KJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07): : 1185 - 1189
  • [39] Lower-extremity function for driving an automobile after operative treatment of ankle fracture
    Carmont, MR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1829 - 1830
  • [40] Effects of ankle support on lower-extremity functional performance: A meta-analysis
    Cordova, ML
    Scott, BD
    Ingersoll, CD
    Leblanc, MJ
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (04): : 635 - 641