Simulation of the Allegro PET system using GATE

被引:4
|
作者
Lamare, F [1 ]
Turzo, A [1 ]
Bizais, Y [1 ]
Visvikis, D [1 ]
机构
[1] CHU Morvan, INSERM, ERM 0102, LaTIM, Brest, France
关键词
GATE; Monte-Carlo simulation; allegro PET system; dead-time modeling;
D O I
10.1117/12.535407
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
GATE (Geant4 Application for Tomographic Emission) was used to perform a Monte-Carlo simulation of a fully 3D clinical PET scanner. The Philips Allegro PET system was simulated in order (a). to allow a detailed study of the parameters affecting the system's performance under various imaging conditions, and (b). to further validate the use of GATE for the simulation of clinical PET systems. A model of the detection system and its geometry was developed. The simulation of count rate related performance characteristics of the scanner was facilitated through the development of a dead time model to describe data flow and data loss at the level of detected single events and coincidences. The developed system design and associated dead time model were validated by comparing simulated with experimental measurements obtained with the Allegro PET system. These measurements included the use of point as well as distributed sources, allowing us to determine spatial resolution, scatter fraction, sensitivity, and count rate performance based on the NEMA NU2 - 1994 protocols. Using the NEMA phantom, simulated single and coincidence count rates were within 5% of the corresponding measured rates throughout a wide range of activity concentrations. Scatter fraction and random coincidences were also measured and combined with total recorded coincidence rates in order to validate simulated NEC rate curves. Differences between simulated and measured NEC curves were found to be within 7% and can be attributed to the approximations in the simulation including no photomultiplier tube response, gantry surroundings or the effects of pulse pile up in the modeling of the electronics. These results support an accurate modelling of the Philips Allegro PET system using GATE in combination with an appropriate dead time model.
引用
收藏
页码:890 / 897
页数:8
相关论文
共 50 条
  • [1] The Application of GATE and NCAT to Respiratory Motion Simulation in Allegro PET
    He, Jianfeng
    O'Keefe, Graeme J.
    Jones, Gareth
    Saunder, Tim
    Gong, Sylvia J.
    Geso, Moshi
    Scott, Andrew M.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2589 - 2593
  • [2] Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE
    Lamare, F
    Turzo, A
    Bizais, Y
    Le Rest, CC
    Visvikis, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 943 - 962
  • [3] Validation of a simultaneous PET/MR system model for PET simulation using GATE
    Florian Monnier
    Hadi Fayad
    Julien Bert
    Holger Schmidt
    Dimitris Visvikis
    [J]. EJNMMI Physics, 2 (Suppl 1)
  • [4] Monte Carlo simulation of MAMMI PET system and performance evaluation using GATE toolkit
    Emami, A.
    Ghadiri, H.
    Ghafarian, P.
    Geramifar, P.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S714 - S714
  • [5] Evaluation of attenuation correction methodology in the allegro PET system
    Talguen, V
    Turzo, A
    Bizais, Y
    Visvikis, D
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2688 - 2692
  • [6] Evaluation of attenuation correction methodology in the Allegro™ PET system
    Talguen, V
    Turzo, A
    Bizais, Y
    Visvikis, D
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3078 - 3081
  • [7] Simulation of time curves in small animal PET using GATE
    Simon, L
    Strul, D
    Santin, G
    Krieguer, M
    Morel, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 190 - 194
  • [8] A Benchmark of clinical PET using GATE simulation on the computing Grid
    Toufique, Y.
    El Moursli, R. Cherkaoui
    Kaci, M.
    El Kharrim, A.
    Merrouch, R.
    [J]. 2013 ACS INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS AND APPLICATIONS (AICCSA), 2013,
  • [9] Monte Carlo simulation in PET and SPECT instrumentation using GATE
    Assié, K
    Breton, V
    Buvat, I
    Comtat, C
    Jan, S
    Krieguer, M
    Lazaro, D
    Morel, C
    Rey, M
    Santin, G
    Simon, L
    Staelens, S
    Strul, D
    Vieira, JM
    Van de Walle, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 180 - 189
  • [10] GATE:: a simulation toolkit for PET and SPECT
    Jan, S
    Santin, G
    Strul, D
    Staelens, S
    Assié, K
    Autret, D
    Avner, S
    Barbier, R
    Bardiès, M
    Bloomfield, PM
    Brasse, D
    Breton, V
    Bruyndonckx, P
    Buvat, I
    Chatziioannou, AF
    Choi, Y
    Chung, YH
    Comtat, C
    Donnarieix, D
    Ferrer, L
    Glick, SJ
    Groiselle, CJ
    Guez, D
    Honore, PF
    Kerhoas-Cavata, S
    Kirov, AS
    Kohli, V
    Koole, M
    Krieguer, M
    van der Laan, DJ
    Lamare, F
    Largeron, G
    Lartizien, C
    Lazaro, D
    Maas, MC
    Maigne, L
    Mayet, F
    Melot, F
    Merheb, C
    Pennacchio, E
    Perez, J
    Pietrzyk, U
    Rannou, FR
    Rey, M
    Schaart, DR
    Schmidtlein, CR
    Simon, L
    Song, TY
    Vieira, JM
    Visvikis, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19): : 4543 - 4561