Kinetics of Highly Sensitive Troponin T after Cardiac Surgery

被引:6
|
作者
Omar, Amr S. [1 ,2 ]
Sudarsanan, Suraj [1 ]
Hanoura, Samy [1 ,3 ]
Osman, Hany [1 ,3 ]
Sivadasan, Praveen C. [1 ]
Shouman, Yasser [1 ]
Tuli, Alejandro Kohn [1 ]
Singh, Rajvir [4 ]
Al Khulaifi, Abdulaziz [1 ]
机构
[1] Hamad Med Corp, Heart Hosp, Dept Cardiothorac Surg, Cardiac Anaesthesia & ICU Sect, Doha, Qatar
[2] Beni Suef Univ, Dept Crit Care Med, Bani Suwayf 62511, Egypt
[3] Al Azhar Univ, Dept Anesthesia, Cairo 11651, Egypt
[4] Hamad Med Corp, Dept Med Res, Doha, Qatar
关键词
PERIOPERATIVE MYOCARDIAL-INFARCTION; SHORT-TERM; VASCULAR-SURGERY; EARLY-DIAGNOSIS; MORTALITY; BIOMARKERS;
D O I
10.1155/2015/574546
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Perioperative myocardial infarction (PMI) confers a considerable risk in cardiac surgery settings; finding the ideal biomarker seems to be an ideal goal. Our aim was to assess the diagnostic accuracy of highly sensitive troponin T (hsTnT) in cardiac surgery settings and to define a diagnostic level for PMI diagnosis. This was a single-center prospective observational study analyzing data from all patients who underwent cardiac surgeries. The primary outcome was the diagnosis of PMI through a specific level. The secondary outcome measures were the lengths of mechanical ventilation (LOV), stay in the intensive care unit (LOSICU), and hospitalization. Based on the third universal definition of PMI, patients were divided into two groups: no PMI (Group I) and PMI (Group II). Data from 413 patients were analyzed. Nine patients fulfilled the diagnostic criteria of PMI, while 41 patients were identified with a 5-fold increase in their CK-MB (>= 120U/L). Using ROC analysis, a hsTnT level of 3,466 ng/L or above showed 90% sensitivity and 90% specificity for the diagnosis of PMI. Secondary outcome measures in patients with PMI were significantly prolonged. In conclusion, the hsTnT levels detected here paralleled those of CK-MB and a cut-off level of 3466 ng/L could be diagnostic of PMI.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] High-sensitive cardiac troponin T
    Xu, Ru-Yi
    Zhu, Xiao-Fa
    Yang, Ye
    Ye, Ping
    JOURNAL OF GERIATRIC CARDIOLOGY, 2013, 10 (01) : 102 - 109
  • [32] Cost-Effectiveness of Highly Sensitive Cardiac Troponin T to Rule Out Acute Rejection After Heart Transplantation
    Mendez, A. B.
    Ordonez-Llanos, J.
    Farrero, M.
    Mirabet, S.
    Brossa, V.
    Lopez, L.
    Bonet, R.
    Sionis, A.
    Perez-Villa, F.
    Roig, E.
    TRANSPLANTATION PROCEEDINGS, 2015, 47 (08) : 2395 - 2396
  • [33] Troponin Testing After Cardiac Surgery
    Januzzi, J. L., Jr.
    HEART LUNG AND VESSELS, 2009, 1 (03) : 22 - 32
  • [34] Highly Sensitive Cardiac Troponin in Blunt Chest Trauma: After the Gathering Comes the Scattering?
    Aristomenis, Exadaktylos
    Thomas, Sauter
    Heinz, Zimmermann
    Beat, Schnueriger
    Daniela, Buhl
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (03): : 766 - 767
  • [35] Timing and threshold of high sensitive troponin T measurement for the prediction of mortality after cardiac surgery: a retrospective cohort analysis
    Kokoefer, Andreas
    Cozowicz, Crispiana
    Wernly, Bernhard
    Rodemund, Niklas
    INTENSIVE CARE MEDICINE EXPERIMENTAL, 2023, 11 (01)
  • [36] Timing and threshold of high sensitive troponin T measurement for the prediction of mortality after cardiac surgery: a retrospective cohort analysis
    Andreas Koköfer
    Crispiana Cozowicz
    Bernhard Wernly
    Niklas Rodemund
    Intensive Care Medicine Experimental, 11
  • [37] A Sensitive Cardiac Troponin T Assay In Cardiac Allograft Recipients
    Erbel, Christian
    Taskin, Rukiye
    Wangler, Susanne
    Doesch, Andreas
    Giannitsis, Evangelos
    Dengler, Thomas J.
    Katus, Hugo A.
    CIRCULATION, 2010, 122 (21)
  • [38] Utility of cardiac troponin measurement after cardiac surgery
    Dehoux, M
    Provenchère, S
    Benessiano, J
    Lasocki, S
    Lecharny, JB
    Bronchard, R
    Dilly, MP
    Philip, I
    CLINICA CHIMICA ACTA, 2001, 311 (01) : 41 - 44
  • [39] Highly sensitive cardiac troponin T level and the degree of myocardial ischemia during cardiac pharmacological stress MRI
    Wongpraparut, N.
    Piyophirapong, S.
    Maneesai, A.
    Sribhen, K.
    Pongasira, R.
    Komoltri, C.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1033 - 1034
  • [40] Cardiac troponin T: a highly sensitive and specific indicator of myocardial injury in patients with cerebrovascular stroke
    Abdelhamid, M. A.
    Hasanin, A. G.
    Abdu, M. A.
    Awwad, O. S.
    EUROPEAN HEART JOURNAL, 2010, 31 : 507 - 508