Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery

被引:8
|
作者
Lopez-Miguel, Alberto [1 ]
Sanchidrian, Maria [1 ,2 ]
Fernandez, Itziar [1 ,3 ]
Holgueras, Alfredo [1 ]
Maldonado, Miguel J. [1 ]
机构
[1] Univ Valladolid, Inst Appl Ophthalmobiol, IOBA, Valladolid, Spain
[2] Rio Hortega Univ Hosp, Valladolid, Spain
[3] Biomed Res Networking Ctr Bioengn Biomat & Nanome, Valladolid, Spain
关键词
Corneal edema; Pachymetry; Specular microscopy; Comparison; CENTRAL CORNEAL THICKNESS; STATISTICAL-METHODS; REPEATABILITY; REPRODUCIBILITY; PRECISION; AGREEMENT; ABLATION; EDEMA;
D O I
10.1007/s00417-016-3537-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare specular microscopy (Topcon SP-3000P, Topcon Corporation, Tokyo, Japan) and ultrasound (US) technology when evaluating central corneal thickness (CCT) prior to and after phacoemulsification. Corneal edema was assessed in phacoemulsification patients due to senile cataract by measuring CCT preoperatively and 1 day, 1 month, and 3 months postoperatively. Bland-Altman analysis was performed to assess interchangeability between pachymetry techniques for each visit. Repeated measures analysis of variance was performed to evaluate variation in CCT agreement depending on the degree of corneal edema. One hundred and eighteen patients aged 73.9 +/- 10.1 years were recruited. Topcon SP-3000P provided significant (p < 0.0001) lower CCT values than US with and without induced corneal edema. Mean differences between CCT techniques for baseline, 1 day, 1 month and 3 months after cataract surgery were -28.9 +/- 22.6, -30.5 +/- 41.4, -32.3 +/- 16.2 and -33.0 +/- 16.9 mu m, respectively. The systematic bias observed was not significantly different among the 4 visits (p = 0.59). The estimated limits of agreement (based on 1.96 standard deviation) were substantial, being 90.5, 165.8, 64.9 and 67.5 um at baseline, 1 day and 1 and 3 months. Topcon SP-3000P provides similar systematic bias in comparison with US technique for CCT measurements regardless of the degree of corneal edema after phacoemulsification, which should be reduced after applying a constant calibration adjustment of similar to 30 mu m. However, interchangeability between techniques may be still limited by the notable random measurement error.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 50 条
  • [1] Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
    Alberto López-Miguel
    María Sanchidrián
    Itziar Fernández
    Alfredo Holgueras
    Miguel J. Maldonado
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 387 - 392
  • [2] Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
    De Bernardo, Maddalena
    Rosa, Nicola
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) : 837 - 838
  • [3] Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
    Maddalena De Bernardo
    Nicola Rosa
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 837 - 838
  • [4] Letter to the editor. “Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery”
    Alberto López-Miguel
    María Sanchidrián
    Itziar Fernández
    Alfredo Holgueras
    Miguel J. Maldonado
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 839 - 840
  • [5] Letter to the editor. "Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery"
    Lopez-Miguel, Alberto
    Sanchidrian, Maria
    Fernandez, Itziar
    Holgueras, Alfredo
    Maldonado, Miguel J.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) : 839 - 840
  • [6] IS SPECULAR MICROSCOPY NECESSARY BEFORE CATARACT-SURGERY
    VIVELL, P
    LUND, OE
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1990, 197 (03) : 265 - 267
  • [7] Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy
    Tam, ES
    Rootman, DS
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (06): : 1179 - 1184
  • [8] Comparison of central corneal thickness as measured by non-contact specular microscopy and ultrasound pachymetry before and post LASIK
    Zhao, Ming-Hui
    Zou, Jun
    Wang, Wen-Qing
    Li, Jun
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09): : 818 - 823
  • [9] Comparison of Central Corneal Thickness Measurements between Noncontact Specular Microscopy and Ultrasound Pachymetry
    Ohn, Kyoung
    Lee, Mee Yon
    Lee, Young Chun
    Shin, Hye Young
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (07): : 635 - 642
  • [10] THE CORNEA - PACHYMETRY, SPECULAR MICROSCOPY EXAMINATION
    WEEKERS, JF
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 1982, 5 (8-9): : 535 - 545