Solid-state mid-infrared laser facilitated coronary angioplasty: Clinical and quantitative coronary angiographic results in 112 patients

被引:0
|
作者
Topaz, O [1 ]
Rozenbaum, EA [1 ]
Schumacher, A [1 ]
Luxenberg, MG [1 ]
机构
[1] UNIV MINNESOTA,ST PAUL RAMSEY MED CTR,SCH MED,SECT CARDIOL,CARDIAC CATHETERIZAT LABS,ST PAUL,MN
关键词
angioplasty; coronary; holmium; infarction; laser; thrombus;
D O I
10.1002/(SICI)1096-9101(1996)19:3<260::AID-LSM2>3.0.CO;2-Q
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: Holmium:YAG is a solid-state, investigational coronary laser device. Preliminary reports indicate the clinical potential for this laser; however, its safety and efficacy in a single center experience have not yet been reported and analyzed in detail. Study Design, Patients, and Methods: One hundred and twelve consecutive symptomatic patients underwent percutaneous holmium:YAG laser (2.1 micron wavelength, 250-600 mJ/pulse, 5 Hz) facilitated coronary angioplasty. Sixty-six patients (Or 1) had 74 thrombotic lesions, and 46 patients (Gr 2) had 55 thrombus-free stenoses. Results: Overall laser success was achieved in 120 out of 129 lesions (93%), with 95% subsequent balloon angioplasty success. Laser and clinical successes among the two groups were similar. By quantitative coronary angiography, reduction in the percent diameter stenosis (mean +/- SD) was similar (79 +/- 16% to 37 +/- 14% vs. 73 +/- 16% to 37 +/- 11.5%; P = NS) in both groups. However; minimal luminal diameter improved significantly more in Or 1 patients, (0.7 +/- 0.5 mm to 2.0 +/- 0.5 mm, vs. 0.9 +/- 0.4 mm to 1.8 +/- 0.4 mm, P = 0.03). Angiographic and clinical complications were similar in patients with thrombus and without thrombus. No death, perforation, or Q-wave infarction occurred in the catheterization laboratory in either group. In-hospital mortality occurred in two patients from cardiac causes unrelated to the laser application. Of the 98 patients who reached the 6 month anniversary, 76 (77%) remained asymptomatic. The restenosis rate among the patients who underwent repeat angiography was 50%. Conclusions: Solid-state, mid-infrared laser can be safely and successfully applied to symptomatic patients with thrombotic and nonthrombotic lesions, Similar to other debulking devices, the effectiveness of this laser in yielding long-term patency has not been proved. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:260 / 272
页数:13
相关论文
共 50 条
  • [31] High-performance wavelength tuning of a mid-infrared solid-state laser using a resonant diffraction grating
    Vermeulen, N.
    Wasylczyk, P.
    Tonchev, S.
    Muys, P.
    Ottevaere, H.
    Parriaux, O.
    Thienpont, H.
    LASER SOURCES AND APPLICATIONS, 2012, 8433
  • [32] Clinical and angiographic predictors of new total occlusions in patients awaiting coronary angioplasty
    de Cock, CC
    Van der Berg, AJ
    Van der Nieuwenhuizen, N
    Bronzwaer, JG
    Visser, CA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 241A - 241A
  • [33] Development Progress of 3-5 μm Mid-Infrared Lasers: OPO, Solid-State and Fiber Laser
    Ren, Tingwei
    Wu, Chunting
    Yu, Yongji
    Dai, Tongyu
    Chen, Fei
    Pan, Qikun
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [34] CLINICAL AND ANGIOGRAPHIC RESULTS IN 50 PATIENTS AFTER CORONARY REVASCULARIZATION
    SCHABELMAN, S
    MITCHELL, W
    WILLIS, W
    JUDKINS, M
    CIRCULATION, 1978, 58 (04) : 26 - 26
  • [35] CLINICAL-RESULTS OF CORONARY EXCIMER-LASER ANGIOPLASTY - REPORT FROM THE EUROPEAN CORONARY EXCIMER-LASER ANGIOPLASTY REGISTRY
    BAUMBACH, A
    OSWALD, H
    KVASNICKA, J
    FLECK, E
    GESCHWIND, HJ
    OZBEK, C
    REIFART, N
    BERTRAND, ME
    KARSCH, KR
    EUROPEAN HEART JOURNAL, 1994, 15 (01) : 89 - 96
  • [36] PERCUTANEOUS CORONARY EXCIMER LASER ANGIOPLASTY - INITIAL CLINICAL-RESULTS
    KARSCH, KR
    MAUSER, M
    VOELKER, W
    HAASE, KK
    ICKRATH, O
    DUDA, S
    SEIPEL, L
    LANCET, 1989, 2 (8664): : 647 - 650
  • [37] Comparison of clinical state and quality of life of patients with and without angiographic follow-up after coronary angioplasty
    Sick, P
    Krutzsch, J
    Krieger, K
    Gelbrich, G
    Schuler, G
    EUROPEAN HEART JOURNAL, 2002, 23 : 685 - 685
  • [38] EXCIMER LASER FACILITATED CORONARY ANGIOPLASTY - RELATIVE RISK ANALYSIS OF ACUTE AND FOLLOW-UP RESULTS IN 200 PATIENTS
    BITTL, JA
    SANBORN, TA
    CIRCULATION, 1992, 86 (01) : 71 - 80
  • [39] Research Progress of Tunable Mid-infrared Solid State Laser Pumped by Near-infrared Laser (Invited)
    Chen Kai
    Xu Degang
    He Yixin
    Zhong Kai
    Li Jining
    Wang Yuye
    Yao Jianquan
    ACTA PHOTONICA SINICA, 2023, 52 (09)
  • [40] Quantitative angiographic results after coronary angioplasty can predict early and long-term outcome
    Martinez, CA
    Froidcoeur, M
    Mathus, F
    Kulbertus, HE
    Legrand, VM
    CIRCULATION, 1997, 96 (08) : 751 - 751