In situ electrochemical enzyme immunoassay on a microchip with surface-functionalized poly(dimethylsiloxane) channel

被引:25
|
作者
Jang, Yoonhee
Oh, Se Young
Park, Je-Kyun
机构
[1] Korea Adv Inst Sci & Technol, Dept BioSyst, Taejon 305701, South Korea
[2] Sogang Univ, Dept Chem & Biomol Engn, Interdisciplinary Program Integrated Biotechnol, Seoul 121742, South Korea
基金
新加坡国家研究基金会;
关键词
electrochemical detection; microchip-based enzyme immunoassay; mouse IgG; PDMS channel; poly(ethyleneglycol);
D O I
10.1016/j.enzmictec.2006.02.020
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper reports a rapid microchip-based electrochemical enzyme immunoassay with surface-functionalized poly(dimethylsiloxane) (PDMS) channel. The microchip fabricated on a glass substrate by photolithography consists of a three-electrode system for electrochemical detection and is assembled with the antibody-immobilized PDMS channel by plasma treatment. For effective immobilization of target antibodies, the internal surface of the PDMS channel is chemically modified into the silane monolayer containing poly(ethyleneglycol) (PEG) groups, which minimize non-specific binding. Due to low height (50 mu m) of the channel dimensions, the microchip provides a rapid immunoassay by reducing the mass transfer resistance between electrodes and immobilized antibodies, and it takes about 8 min for total analysis time including sampling, reaction and washing step. In this study, sandwich immunoassays for mouse IgG are performed as a model system and result in a low detection limit of 485 pg mL(-1) with 95% confidence level. All immunoassay procedures for liquid handling such as sampling, reaction and washing are carried out using conventional syringe pumps, preserving an internal channel volume of 0.7 mu L constant. Such an on-chip integration of immunological and enzymatic reactions, amperometric detection, and microchip operations allows performing immunoassays more rapidly, easily, and economically. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1122 / 1127
页数:6
相关论文
共 50 条
  • [41] Development of a microfabricated palladium decoupler/electrochemical detector for microchip capillary electrophoresis using a hybrid glass/poly(dimethylsiloxane) device
    Lacher, NA
    Lunte, SM
    Martin, RS
    ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2482 - 2491
  • [42] Microchip reversed-phase liquid chromatography with packed column and electrochemical flow cell using polystyrene/poly(dimethylsiloxane)
    Ishida, Akihiko
    Natsume, Masamichi
    Kamidate, Tamio
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 209 - 217
  • [43] Synthesis and cytotoxic activities of chloropyridylimineplatinum(II) and chloropyridyliminecopper(II) surface-functionalized poly(amidoamine) dendrimers
    Zhao, Xinxin
    Loo, Say Chye Joachim
    Lee, Peter Peng-Foo
    Tan, Timothy Thatt Yang
    Chu, Chit Kay
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2010, 104 (02) : 105 - 110
  • [44] Surface-functionalized MoS2 ultrathin nanosheets for electrochemical monitoring terminal deoxynucleotidyl transferase activity based on in-situ polymerized DNA
    Du, Cuicui
    Shang, Anqi
    Shang, Mengxiang
    Zhang, Jinling
    Song, Wenbo
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 277 : 297 - 305
  • [45] Preparation of a poly-alkylamine surface-functionalized carbon with excellent performance as a Pd(II) scavenger
    Penas-Sanjuan, Antonio
    Lopez-Garzon, Rafael
    Lopez-Garzon, Javier
    Perez-Mendoza, Manuel
    Melguizo, Manuel
    CARBON, 2012, 50 (06) : 2350 - 2352
  • [46] Molecular tunability of surface-functionalized metal nanocrystals for selective electrochemical CO2 reduction
    Pankhurst, James R.
    Guntern, Yannick T.
    Mensi, Mounir
    Buonsanti, Raffaella
    CHEMICAL SCIENCE, 2019, 10 (44) : 10356 - 10365
  • [47] Surface-Functionalized Hyperbranched Poly(Amido Acid) Magnetic Nanocarriers for Covalent Immobilization of a Bacterial γ-Glutamyltranspeptidase
    Juang, Tzong-Yuan
    Kan, Shao-Ju
    Chen, Yi-Yu
    Tsai, Yi-Lin
    Lin, Min-Guan
    Lin, Long-Liu
    MOLECULES, 2014, 19 (04): : 4997 - 5012
  • [48] Rapid and Easy Extracellular Vesicle Detection on a Surface-Functionalized Power-Free Microchip toward Point-of-Care Diagnostics
    Ishihara, Ryo
    Nakajima, Tadaaki
    Uchino, Yoshitaka
    Katagiri, Asuka
    Hosokawa, Kazuo
    Maeda, Mizuo
    Tomooka, Yasuhiro
    Kikuchi, Akihiko
    ACS OMEGA, 2017, 2 (10): : 6703 - 6707
  • [49] Oxygen permeability of surface-modified poly(dimethylsiloxane) characterized by scanning electrochemical microscopy
    Shiku, H
    Saito, T
    Wu, CC
    Yasukawa, T
    Yokoo, M
    Abe, H
    Matsue, T
    Yamada, H
    CHEMISTRY LETTERS, 2006, 35 (02) : 234 - 235
  • [50] The Structure, Morphology, and Complex Permittivity of Epoxy Nanodielectrics with In Situ Synthesized Surface-Functionalized SiO2
    Adnan, Mohammed Mostafa
    Nylund, Inger-Emma
    Jaworski, Aleksander
    Hvidsten, Sverre
    Ese, Marit-Helen Glomm
    Glaum, Julia
    Einarsrud, Mari-Ann
    POLYMERS, 2021, 13 (09)