New developments in radiochromic film dosimetry

被引:47
|
作者
Soares, C. G. [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
关键词
D O I
10.1093/rpd/nci698
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
NIST has been a pioneer in the use of radiochromic film for medical dosimetry applications. Beginning in 1988 with experiments with Sr-90/Y ophthalmic applicators, this work has continued into the present. A review of the latest applications is presented, which include high activity low-energy photon source dosimetry and ultra-high resolution film densitometry for dose enhancement near stents and microbeam radiation therapy dosimetry. An exciting recent development is the availability of a new radiochromic emulsion which has been developed for IMRT dosimetry. This emulsion is an order of magnitude more sensitive than was previously available. Measurements of the sensitivity and uniformity of samples of this new film are reported, using a spectrophotometer and two scanning laser densitometers. A unique feature of the new emulsion is that the peak of the absorbance spectrum falls at the wavelength of the HeNe lasers used in the densitometer, maximising sensitivity. When read at a wavelength of 633 nm, sensitivities on the order of 900 mAU Gy(-1) were determined for this new film type, compared with about 40 mAU Gy(-1) for type HS film, 20 mAU Gy(-1) for type MD-55-2 film, and 3 mAU Gy(-1) for type HD-810. Film uniformities were found to be good, on the order of 6% peak to peak. However, there is a strong polarisation effect in the samples examined, requiring care in film orientation during readout.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 50 条
  • [1] Radiochromic film dosimetry
    Soares, Christopher G.
    RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [2] A new method of readout in radiochromic film dosimetry
    Kellermann, PO
    Ertl, A
    Gornik, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08): : 2251 - 2263
  • [3] Dosimetric characteristics of a new radiochromic film for IMRT dosimetry
    Soares, C
    Lombardi, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1725 - 1725
  • [4] Radiochromic film dosimetry for a new electronic brachytherapy source
    Chiu-Tsao, S
    Rusch, T
    Axelrod, S
    Tsao, H
    Harrison, L
    MEDICAL PHYSICS, 2004, 31 (06) : 1913 - 1913
  • [5] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [6] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603
  • [7] The development of a new radiochromic film protocol for ThreeDimensional and beta dosimetry
    Griffin, S.
    Selwyn, R.
    DeWerd, L.
    MEDICAL PHYSICS, 2007, 34 (06) : 2494 - 2494
  • [8] A RADIOCHROMIC DYE FILM FOR UV DOSIMETRY
    REHIM, FA
    GAWAD, ASA
    FATTAH, AAA
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1992, 64 (01) : 123 - 131
  • [9] Radiochromic film dosimetry in water phantoms
    Butson, MJ
    Cheung, T
    Yu, PKN
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01): : N27 - N31
  • [10] Ultraviolet radiation dosimetry with radiochromic film
    Butson, MJ
    Cheung, T
    Yu, PKN
    Abbati, D
    Greenoak, GE
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1863 - 1868