Radiochromic film dosimetry in water phantoms

被引:28
|
作者
Butson, MJ
Cheung, T
Yu, PKN
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 01期
关键词
D O I
10.1088/0031-9155/46/1/405
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of him orientation during irradiation in water are also tested. Results show that only a small penetration rate is seen from water into the film which only affects the outer areas of the film, with penetration being less than 0.5 mm per hour. The optical density measurements of the film at 660 nm remain unchanged in the unaffected regions of the radiochromic film. Minimal effects are seen due to beam orientation in a water phantom as opposed to solid water phantoms in which an overestimation in dose is normally seen for parallel irradiation. Radiochromic film seems to be an adequate detector for dosimetry in a water phantom where high spatial resolution is needed and angle of beam incidence at the point of interest is important.
引用
收藏
页码:N27 / N31
页数:5
相关论文
共 50 条
  • [1] Radiochromic film dosimetry
    Soares, Christopher G.
    [J]. RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [2] Radiochromic Film Dosimetry Update
    Niroomand-Rad, A.
    Chiu-Tsao, S.
    Trichter, S.
    Das, I.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3626 - 3626
  • [3] Eigencolor radiochromic film dosimetry
    Bouchard, Hugo
    Billas, Ilias
    Subiel, Anna
    Duane, Simon
    [J]. MEDICAL PHYSICS, 2021, 48 (05) : 2592 - 2603
  • [4] A RADIOCHROMIC DYE FILM FOR UV DOSIMETRY
    REHIM, FA
    GAWAD, ASA
    FATTAH, AAA
    [J]. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1992, 64 (01) : 123 - 131
  • [5] Ultraviolet radiation dosimetry with radiochromic film
    Butson, MJ
    Cheung, T
    Yu, PKN
    Abbati, D
    Greenoak, GE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (07): : 1863 - 1868
  • [6] Radiochromic film for medical radiation dosimetry
    Butson, MJ
    Yu, PKN
    Cheung, T
    Metcalfe, P
    [J]. MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5): : 61 - 120
  • [7] New developments in radiochromic film dosimetry
    Soares, C. G.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 100 - 106
  • [8] Protocol For Simplified Radiochromic Film Dosimetry
    Lewis, D.
    Chan, M.
    Micke, A.
    Yu, X.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3741 - 3741
  • [9] Dosimetry of blood irradiation with radiochromic film
    Butson, MJ
    Yu, PKN
    Cheung, T
    Carolan, MG
    Quach, KY
    Arnold, A
    Metcalfe, PE
    [J]. TRANSFUSION MEDICINE, 1999, 9 (03) : 205 - 208
  • [10] Model selection for radiochromic film dosimetry
    Mendez, I.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4089 - 4104