Quantitative analysis of sphingolipids for lipidomics using triple quadrupole and quadrupole linear ion trap mass spectrometers

被引:332
|
作者
Shaner, Rebecca L. [1 ]
Allegood, Jeremy C. [1 ]
Park, Hyejung [2 ]
Wang, Elaine [2 ]
Kelly, Samuel [2 ]
Haynes, Christopher A. [2 ]
Sullards, M. Cameron [1 ,2 ]
Merrill, Alfred H., Jr. [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Biol, Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
关键词
lipid maps; lipidomics internal standards; mass spectrometry; RAW; 264.7; macrophage; sphingolipids; PERFORMANCE LIQUID-CHROMATOGRAPHY; CRUDE CELLULAR-EXTRACTS; PRESSURE CHEMICAL-IONIZATION; THIN-LAYER-CHROMATOGRAPHY; STRUCTURAL-CHARACTERIZATION; NEUTRAL GLYCOSPHINGOLIPIDS; ELECTROSPRAY; CERAMIDE; SPHINGOMYELIN; GANGLIOSIDES;
D O I
10.1194/jlr.D800051-JLR200
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Sphingolipids are a highly diverse category of bioactive compounds. This article describes methods that have been validated for the extraction, liquid chromatographic (LC) separation, identification and quantitation of sphingolipids by electrospray ionization, tandem mass spectrometry (ESI-MS/MS) using triple quadrupole (QQQ, API 3000) and quadrupole-linear-ion trap (API 4000 QTrap, operating in QQQ mode) mass spectrometers. Advantages of the QTrap included: greater sensitivity, similar ionization efficiencies for sphingolipids with ceramide versus dihydroceramide backbones, and the ability to identify the ceramide backbone of sphingomyelins using a pseudo-MS 3 protocol. Compounds that can be readily quantified using an internal standard cocktail developed by the LIPID MAPS Consortium are: sphingoid bases and sphingoid base 1-phosphates, more complex species such as ceramides, ceramide 1-phosphates, sphingomyelins, mono-and di-hexosylceramides, and these complex sphingolipids with dihydroceramide backbones. With minor modifications, glucosylceramides and galactosylceramides can be distinguished, and more complex species such as sulfatides can also be quantified, when the internal standards are available. LC ESI-MS/MS can be utilized to quantify a large number of structural and signaling sphingolipids using commercially available internal standards. The application of these methods is illustrated with RAW264.7 cells, a mouse macrophage cell line. These methods should be useful for a wide range of focused (sphingo) lipidomic investigations.-Shaner, R. L., J. C. Allegood, H. Park, E. Wang, S. Kelly, C. A. Haynes, M. C. Sullards, and Alfred H. Merrill, Jr. Quantitative analysis of sphingolipids for lipidomics using triple quadrupole and quadrupole linear ion trap mass spectrometers. J. Lipid Res. 2009. 50: 1692-1707.
引用
收藏
页码:1692 / 1707
页数:16
相关论文
共 50 条
  • [41] Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro - amitriptyline and verapamil as model compounds
    Rousu, Timo
    Herttuainen, Jukka
    Tolonen, Ari
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (07) : 939 - 957
  • [42] ENHANCED MASS RESOLUTION IN A QUADRUPOLE ION TRAP
    LONDRY, FA
    WELLS, GJ
    MARCH, RE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (01) : 43 - 45
  • [43] A dual quadrupole ion trap mass spectrometer
    Zerega, Y
    Perrier, P
    Carette, M
    Brincourt, G
    Nguema, T
    Andre, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 191 : 59 - 68
  • [44] Quadrupole ion trap mass spectrometry - Introduction
    McLuckey, SA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 191 : VIII - IX
  • [45] An introduction to quadrupole ion trap mass spectrometry
    March, RE
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (04): : 351 - 369
  • [46] Quantitative analysis of 17 hypoglycemic drugs in fingerprints using ultra-high-performance liquid chromatography/tandem hybrid triple quadrupole linear ion trap mass spectrometry
    Du, Qiuyao
    Zhang, Yunfeng
    Wang, Jifen
    Chang, Jing
    Wang, Aihua
    Ren, Xinxin
    Liu, Bingjie
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (01)
  • [47] QUADRUPOLE ION TRAP MASS-SPECTROMETRY
    COOKS, RG
    KAISER, RE
    ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (07) : 213 - 219
  • [48] Quadrupole-Linear Ion Trap Tandem Mass Spectrometry System for Clinical Biomarker Analysis
    Fang, Xiang
    Xie, Jie
    Chu, Shiying
    Jiang, You
    An, Yuting
    Li, Chang
    Gong, Xiaoyun
    Zhai, Rui
    Huang, Zejian
    Qiu, Chunling
    Dai, Xinhua
    ENGINEERING, 2022, 16 : 56 - 64
  • [49] Quadrupole-Linear Ion Trap Tandem Mass Spectrometry System for Clinical Biomarker Analysis
    Xiang Fang
    Jie Xie
    Shiying Chu
    You Jiang
    Yuting An
    Chang Li
    Xiaoyun Gong
    Rui Zhai
    Zejian Huang
    Chunling Qiu
    Xinhua Dai
    Engineering, 2022, 16 (09) : 56 - 64
  • [50] Factors determining the performance of triple quadrupole, quadrupole ion trap and sector field mass spectrometers in electrospray ionization tandem mass spectrometry of oligonucleotides. 1. Comparison of performance characteristics
    Premstaller, A
    Ongania, KH
    Huber, CG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (13) : 1045 - 1052