Stable top-up operation at SPring-8

被引:35
|
作者
Tanaka, Hitoshi
Adachi, Masatoshi
Aoki, Tsuyoshi
Asaka, Takao
Baron, Alfred
Date, Shin
Fukami, Kenji
Furukawa, Yukito
Hanaki, Hirofumi
Hosoda, Naoyasu
Ishikawa, Tetsuya
Kimura, Hiroaki
Kobayashi, Kazuo
Kobayashi, Toshiaki
Kohara, Shinji
Kumagai, Noritaka
Masaki, Mitsuhiro
Masuda, Takemasa
Matsui, Sakuo
Mizuno, Akihiko
Nakamura, Takeshi
Nakatani, Takeshi
Noda, Takashi
Ohata, Toru
Ohkuma, Haruo
Ohshima, Takashi
Oishi, Masaya
Sasaki, Sigeki
Schimizu, Jun
Shoji, Masazumi
Soutome, Kouichi
Suzuki, Motohiro
Suzuki, Shinsuke
Suzuki, Yoshio
Takano, Shirou
Takao, Masaru
Takashima, Takeo
Takebe, Hideki
Takeuchi, Akihisa
Tamura, Kazuhiro
Tanaka, Ryotaro
Tanaka, Yoshihito
Taniuchi, Tsutomu
Taniuchi, Yukiko
Tsumaki, Kouji
Yamashita, Akihiro
Yanagida, Kenichi
Yoda, Yoshitaka
Yonehara, Hiroto
Yorita, Tetsuhiko
机构
[1] SPring 8, Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
[2] Spring 8 Serv, Kamigori, Hyogo 6781205, Japan
[3] RIKEN, Harima Inst, SPring 8, Sayo, Hyogo 6795198, Japan
[4] JAEA, Quantum Beam Sci Directorate, Tokai, Ibaraki 3191195, Japan
关键词
top-up operation; injection-beam loss; purity; stability; thermal equilibrium; heat load;
D O I
10.1107/S0909049506022862
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Top-up operation allows SPring-8 to provide highly stable X-ray beams with arbitrary filling patterns. The implementation of top-up operation is described, with a focus on the simultaneous achievement of stability of stored current, beam orbit, purity of an isolated single bunch, and beam injection efficiency. Stored-current fluctuations have been routinely reduced to a level of 10(-3). Stored-beam oscillation on frequent beam injection, which was originally regarded as the most serious problem, has been successfully suppressed to a sufficiently low level that it never perturbs imaging experiments. Current impurities in nominally empty buckets have been reduced to a level of 10(-9) over more than one week of operation, making possible the measurement of time-resolved spectra using high-current bunches. Finally, excellent injection efficiency, higher than 80%, is routinely obtained, even for small undulator gaps, which is critical for preventing radiation damage to insertion-device magnets and to reduce leakage radiation. The process of achieving highly stabilized top-up operation at SPring-8 and its utility for user experiments are described.
引用
收藏
页码:378 / 391
页数:14
相关论文
共 50 条
  • [1] Radiation safety issues for top-up operation at SPring-8
    Asano, Yoshihiro
    Takagi, Tetsuya
    [J]. RADIATION MEASUREMENTS, 2006, 41 : S236 - S241
  • [2] Enhancements of machine reliability and beam quality in SPring-8 linac for top-up injection into two storage rings
    Hanaki, H
    Asaka, T
    Dewa, H
    Kobayashi, T
    Mizuno, A
    Suzuki, S
    Taniuchi, T
    Tomizawa, H
    Yanagida, K
    [J]. 2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 248 - 250
  • [3] Radiation safety impact for top-up operation at the NSRRC
    Sheu, RJ
    Wang, JP
    Liu, J
    Chen, CR
    Chang, FD
    Jiang, SH
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 239 - 244
  • [4] Top-up fees - Top-up fairly according to means
    Lake, Alfred P. J.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2008, 336 (7655): : 1205 - 1205
  • [5] Top-up fees - Not allowing top-up fees is unethical
    Lees, Christoph C.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2008, 336 (7655): : 1205 - 1205
  • [6] Preparing the BESSY APPLE undulators for top-up operation
    Bahrdt, J.
    Frentrup, W.
    Gaupp, A.
    Scheer, M.
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 315 - +
  • [7] Automated Operation of Protein Crystallography Beamlines at the SPring-8
    Yamamoto, Masaki
    Ueno, Go
    Hirose, Raita
    Ida, Koh
    Kumasaka, Takashi
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C56 - C56
  • [8] Safety upgrades for NSRRC beamlines in the upcoming top-up operation
    Liu, Joseph C.
    Sheu, Rong-Jiun
    Wang, Jau-Ping
    Chen, Chien-Rong
    Chang, Fu-Dong
    Kao, Sheau-Ping
    [J]. RADIATION MEASUREMENTS, 2006, 41 : S242 - S246
  • [9] Diagnostic and timing supports for top-up injection operation for the TLS
    Hu, K. H.
    Lee, Demi
    Wu, C. Y.
    Hsu, S. Y.
    Chen, Jenny
    Kuo, C. H.
    Wang, C. J.
    Chiu, P. C.
    Hsu, K. T.
    [J]. 2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 247 - 249
  • [10] Top-up trials
    不详
    [J]. VETERINARY RECORD, 2003, 153 (23) : 693 - 693