Supraglottic airway devices vs tracheal intubation in children: a quantitative meta-analysis of respiratory complications

被引:69
|
作者
Luce, Virginie [1 ,2 ]
Harkouk, Hakim [1 ,2 ]
Brasher, Christopher [1 ,2 ]
Michelet, Daphne [1 ,2 ]
Hilly, Julie [1 ,2 ]
Maesani, Matthieu [1 ,2 ]
Diallo, Thierno [1 ,2 ]
Mangalsuren, Nyamjargal [1 ,2 ]
Nivoche, Yves [1 ,2 ]
Dahmani, Souhayl [1 ,2 ,3 ]
机构
[1] RobertDebre Univ Hosp, Dept Anesthesia, Paris, France
[2] Univ Paris 07, Sorbonne Paris Cite, Paris, France
[3] Robert Debre Univ Hosp, INSERM UMR U 676, Paris, France
关键词
laryngeal mask; tracheal intubation; laryngospasm; children; bronchospasm; respiratory complications; airway; desaturation; LARYNGEAL-MASK-AIRWAY; PEDIATRIC ANESTHESIA; ENDOTRACHEAL INTUBATION; SYSTEMATIC REVIEWS; TUBE; PRESSURE; REMOVAL; SURGERY; LMA; PUBLICATION;
D O I
10.1111/pan.12495
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Rate of perioperative respiratory complications between tracheal intubation (TI) and laryngeal mask airway remains unclear during pediatric anesthesia. Objectives: The aim of the present meta-analysis was to compare the perioperative respiratory complications between laryngeal mask airway and TI. Methods: A meta-analysis of available controlled studies comparing laryngeal mask airway to TI was conducted. Studies including patients with airway infection were excluded. Data from each trial were combined to calculate the pooled odds ratios (OR) or mean difference (MD) and 95% confidence intervals. Results: The meta-analysis was performed on 19 studies. In 12 studies, patients were given muscle relaxation, and in 16 studies, ventilation was controlled. During recovery from anesthesia, the incidence of desaturation (OR = 0.34 [0.19-0.62]), laryngospasm (OR = 0.34 [0.2-0.6]), cough (OR = 0.18 [0.11-0.27]), and breath holding (0.19 [0.05-0.68]) was lower when laryngeal mask airway was used to secure the airway. Postoperative incidences of sore throat (OR = 0.87 [0.53-1.44]), bronchospasm (OR = 0.56 [0.25-1.25]), aspiration (1.33 [0.46-3.91]) and blood staining on the device (OR = 0.62 [0.21-1.82]) did not differ between laryngeal mask airway and TI. Results were homogenous across the studies, with the exceptions of blood staining on the device. Conclusions: This meta-analysis found that the use of laryngeal mask airway in pediatric anesthesia results in a decrease in a number of common postanesthetic complications. It is therefore a valuable device for the management of the pediatric airway.
引用
收藏
页码:1088 / 1098
页数:11
相关论文
共 50 条
  • [11] Supraglottic airway devices for surfactant treatment: systematic review and meta-analysis
    Calevo, Maria Grazia
    Veronese, Nicola
    Cavallin, Francesco
    Paola, Cavicchioli
    Micaglio, Massimo
    Trevisanuto, Daniele
    JOURNAL OF PERINATOLOGY, 2019, 39 (02) : 173 - 183
  • [12] Comparison of supraglottic airway devices in laparoscopic surgeries: A network meta-analysis
    Yoon, Sang Won
    Kang, Hyun
    Choi, Geun Joo
    Ryu, Choongun
    Park, Yong Hee
    Baek, Chong Wha
    Jung, Yong Hun
    Woo, Young Cheol
    JOURNAL OF CLINICAL ANESTHESIA, 2019, 55 : 52 - 66
  • [13] Supraglottic airway devices versus tracheal intubation for airway management during general anaesthesia in obese patients
    Nicholson, Amanda
    Cook, Tim M.
    Smith, Andrew F.
    Lewis, Sharon R.
    Reed, Stephanie S.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (09):
  • [14] Laryngeal Mask Airway Versus Other Airway Devices for Anesthesia in Children With an Upper Respiratory Tract Infection: A Systematic Review and Meta-analysis of Respiratory Complications
    de Carvalho, Ana Lygia R.
    Vital, Roberto B.
    de Lira, Carlos C. S.
    Magro, Igor B.
    Sato, Patricia T. S.
    Lima, Lais H. N.
    Braz, Leandro G.
    Modolo, Norma S. P.
    ANESTHESIA AND ANALGESIA, 2018, 127 (04): : 941 - 950
  • [15] Comparison of laryngeal mask airway vs tracheal intubation: a systematic review on airway complications
    van Esch, Babette F.
    Stegeman, Inge
    Smit, Adriana. L.
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 36 : 142 - 150
  • [16] Pentax Airway Scope® vs Macintosh laryngoscope for tracheal intubation in adult patients: a systematic review and meta-analysis
    Hoshijima, H.
    Kuratani, N.
    Hirabayashi, Y.
    Takeuchi, R.
    Shiga, T.
    Masaki, E.
    ANAESTHESIA, 2014, 69 (08) : 911 - 918
  • [17] Optimal size and length of the endotracheal tube for tracheal intubation via supraglottic airway devices Reply
    Takenaka, Ichiro
    Aoyama, Kazuyosi
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (06): : 625 - 625
  • [18] Comparison of Supraglottic Airway Devices With Endotracheal Intubation in Low-Risk Patients for Cesarean Delivery: Systematic Review and Meta-analysis
    White, Leigh D.
    Thang, Christopher
    Hodsdon, Anthony
    Melhuish, Thomas M.
    Barron, Fiona A.
    Godsall, M. Guy
    Vlok, Ruan
    ANESTHESIA AND ANALGESIA, 2020, 131 (04): : 1092 - 1101
  • [19] Supraglottic airway devices versus endotracheal intubation for laparoscopic surgeries: An updated systematic review and meta-analysis of randomised controlled trials
    Kumar, Tushar
    Bharati
    Suman, Saurabh
    Kumar, Sanjay
    Acharya, Gaurav
    Lakra, Ladhu
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (05) : 409 - +
  • [20] Blind tracheal intubation through 2 supraglottic devices: the Ambu AuraGain vs the LMA Fastrach
    Lopez Correa, Teresa
    Sastre, Jose A.
    Garzon, Jose C.
    EMERGENCIAS, 2016, 28 (02): : 83 - 88