Dynamic Modification and Damage Propagation of a Two-Storey Full-Scale Masonry Building

被引:14
|
作者
Kouris, Leonidas Alexandros S. [1 ,2 ]
Penna, Andrea [3 ,4 ]
Magenes, Guido [3 ,4 ]
机构
[1] IUSS Pavia, Inst Adv Studies, Pza Vittoria 15, I-27100 Pavia, Italy
[2] European Commiss, Joint Res Ctr, Directorate Space Secur & Migrat, Safety & Secur Bldg Unit, Via E Fermi 2749, I-21027 Ispra, Italy
[3] European Ctr Training & Res Earthquake Engn, V Ferrata 1, I-27100 Pavia, Italy
[4] Univ Pavia, DICAr, V Ferrata 3, I-27100 Pavia, Italy
关键词
D O I
10.1155/2019/2396452
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The progressive change of modal characteristics due to accumulated damage on an unreinforced masonry (URM) building is investigated. The stone URM building, submitted to five consecutive shakings, has been experimentally studied on the shaking table of EUCENTRE laboratory (Pavia, Italy). The dynamic characteristics of the test specimen are analytically estimated using frequency and state-space modal identification from ambient vibration stationary tests carried out before the strong motion transient tests at various levels of damage. A singular value (SV) decomposition of the cross-correlation matrix of the acceleration response in the frequency domain is applied to determine the modal characteristics. In the time domain, the subspace state-space system identification is performed. Modal characteristics evolve from the initial linear state up to the ultimate collapse state in correlation with accumulated damage. Modal frequencies shorten with increasing intensity, whereas modal damping ratios are enhanced. Modal shapes also change with increasing level of accumulated damage. Comparing the evolution of modal characteristics, it is concluded that modal damping ratio shift can be better correlated with the system's actual performance giving a better representation of damage than that of natural frequency shift ratio or the modes difference.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] SEISMIC RESPONSE OF FULL-SCALE 5-STORY REINFORCED-MASONRY BUILDING
    SEIBLE, F
    PRIESTLEY, MJN
    KINGSLEY, GR
    KURKCHUBASCHE, AG
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (03): : 925 - 946
  • [32] Study of Vertical Load Distribution in Full-Scale Four-Story Masonry Building
    Andolfato, R. P.
    Ramalho, M. A.
    Correa, M. R. S.
    Haach, V. G.
    ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 685 - 691
  • [33] SHAKING TABLE TEST OF A STRENGTHENED FULL-SCALE STONE MASONRY BUILDING WITH FLEXIBLE DIAPHRAGMS
    Magenes, Guido
    Penna, Andrea
    Senaldi, Ilaria Enrica
    Rota, Maria
    Galasco, Alessandro
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2014, 8 (03) : 349 - 375
  • [34] Retrofitting of Full-Scale Confined Masonry Building Using Ferro-Cement Overlay
    Shah, Syed Mustafa Ali
    Shahzada, Khan
    Gencturk, Bora
    Memon, Shazim Ali
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (05)
  • [35] Fire tests on two-way concrete, slabs in a full-scale multi-storey steel-framed building
    Yang, Z. N.
    Dong, Y. L.
    Xu, W. J.
    FIRE SAFETY JOURNAL, 2013, 58 : 38 - 48
  • [36] Dynamic Shake-Table Tests on Two Full-Scale, Unreinforced Masonry Buildings Subjected to Induced Seismicity
    Guerrini, Gabriele
    Graziotti, Francesco
    Penna, Andrea
    Magenes, Guido
    EXPERIMENTAL VIBRATION ANALYSIS FOR CIVIL STRUCTURES: TESTING, SENSING, MONITORING, AND CONTROL, 2018, 5 : 376 - 387
  • [37] Seismic assessment of a lab-tested two-storey unreinforced masonry Dutch terraced house
    Rita Esposito
    Francesco Messali
    Geert J. P. Ravenshorst
    H. Roel Schipper
    Jan G. Rots
    Bulletin of Earthquake Engineering, 2019, 17 : 4601 - 4623
  • [38] Experimental study on the seismic performance of two-storey UHPC modular building structure
    He, Qing-Feng
    Zou, Jun-Ming
    Zhang, Chen-Feng
    Zhong, Yi
    Li, Jin-Shi
    Yi, Wei-Jian
    Journal of Building Engineering, 2024, 97
  • [39] Damage diagnosis of a two-storey spatial steel braced-frame model
    Xiaodong, Ji
    Jiaru, Qian
    Longhe, Xu
    STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (08): : 1083 - 1100
  • [40] Confined vs. unreinforced masonry: Construction and shaking table tests of two-storey buildings
    Gioffre, Massimiliano
    Cavalagli, Nicola
    Gusella, Vittorio
    Pepi, Chiara
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 333