Accuracy of 3D/3D and 3D/2D Registration in Intracranial Radiosurgery Using 6DOF Robotic Couch

被引:0
|
作者
Kuo, H. [1 ]
Berry, S. [2 ]
Ballangrud, A. [2 ]
Atwal, P. S. [3 ]
Della Biancia, C. [2 ]
Pathare, P. [4 ]
Shasha, D. [5 ]
Lovelock, D. [2 ]
Hunt, M. [2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Norwalk, CT USA
[2] Mem Sloan Kettering Canc Ctr, 1275 York Ave, New York, NY 10021 USA
[3] BC Canc Abbotsford, Abbotsford, BC, Canada
[4] Norwalk Hosp, Norwalk Hospial, Norwalk, CT 06856 USA
[5] Mem Sloan Kettering Canc Ctr, Nwe York, NY USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MO-I345-Ge
引用
收藏
页码:E436 / E436
页数:1
相关论文
共 50 条
  • [21] Robust 2D/3D Calibration Using RANSAC Registration
    Fortenbury, Billy Ray
    Guerra-Filho, Gutemberg
    [J]. ADVANCES IN VISUAL COMPUTING, ISVC 2012, PT I, 2012, 7431 : 179 - 188
  • [22] Endoscopic navigation system using 2D/3D registration
    Hummel, Johann
    Figl, Michael
    Bergmann, Helmar
    Birkfellner, Wolfgang
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [23] Kinematic registration in 3D using the 2D Reuleaux method
    Eberharter, JK
    Ravani, B
    [J]. JOURNAL OF MECHANICAL DESIGN, 2006, 128 (02) : 349 - 355
  • [24] 2D/3D deformable registration using a hybrid atlas
    Tang, TSY
    Ellis, RE
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 223 - 230
  • [25] A phantom study to evaluate three different registration platform of 3D/3D, 2D/3D, and 3D surface match with 6D alignment for precise image-guided radiotherapy
    Kuo, Hsiang-Chi
    Lovelock, Michael M.
    Li, Guang
    Ballangrud, Ase
    Wolthuis, Brian
    Della Biancia, Cesar
    Hunt, Margie A.
    Berry, Sean L.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 188 - 196
  • [26] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    [J]. CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [27] Spectral 6DOF Registration of Noisy 3D Range Data with Partial Overlap
    Buelow, Heiko
    Birk, Andreas
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2013, 35 (04) : 954 - 969
  • [28] 3D head pose-normalization using 2D and 3D interaction
    Kim, Joongrock
    Yu, Sunjin
    Lee, Sangyoun
    [J]. 2007 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS, VOLS 1-6, 2007, : 1106 - +
  • [29] 3D FACIAL EXPRESSION ANALYSIS BY USING 2D AND 3D WAVELET TRANSFORMS
    Pinto, S. C. D.
    Mena-Chalco, J. P.
    Lopes, F. M.
    Velho, L.
    Cesar Junior, R. M.
    [J]. 2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 1281 - 1284
  • [30] CASE STUDY - Beauty and the Beast 3D Benefits of 3D Viewing for 2D to 3D Conversion
    Turner, Tara Handy
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XXI, 2010, 7524