Both flow-mediated dilation and constriction are associated with changes in blood flow and shear stress: Two complementary perspectives on endothelial function

被引:18
|
作者
Gori, Tommaso [1 ,2 ]
von Henning, Urs [1 ,2 ]
Muxel, Selina [1 ,2 ]
Schaefer, Sarina [1 ,2 ]
Fasola, Federica [1 ,2 ]
Vosseler, Marcus [1 ,2 ]
Schnorbus, Boris [1 ,2 ]
Binder, Harald [3 ]
Parker, John D. [4 ,5 ]
Muenzel, Thomas [1 ,2 ]
机构
[1] Zentrum Kardiol, Kardiol 1, Mainz, Germany
[2] DZHK Standort Rhein Main, Mainz, Germany
[3] Univ Med Ctr Mainz, Inst Med Biometrie Epidemiol & Informat, Mainz, Germany
[4] Univ Toronto, Mt Sinai Hosp, Div Cardiol, Dept Med, Toronto, ON M5S 1A1, Canada
[5] Univ Toronto, Univ Hlth Network Hosp, Toronto, ON M5S 1A1, Canada
关键词
Endothelium/vascular type/nitric oxide; pathophysiology; coronary circulation; BRACHIAL-ARTERY; CONDUIT ARTERIES; NITRIC-OXIDE; VASODILATION; DILATATION; VASOCONSTRICTION; INFORMATION;
D O I
10.3233/CH-168102
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
INTRODUCTION: Flow-mediated dilation (FMD) quantifies endothelium-dependent vasomotor responses to short-term increases in blood flow. Low-flow mediated vasoconstriction (L-FMC) has been more recently introduced as additional measure of endothelial function, and its relationship with changes in blood flow, cardiovascular risk factors and FMD ha. s been less well characterized. MATERIALS AND METHODS: We evaluated radial artery FMD and L-FMC along with the changes in blood flow and shear rate/stress in 584 patients with known or suspected coronary artery disease (72.9% men, mean age 67+/-11 years). Baseline blood flow and shear rate showed a modest association with radial artery FMD and L-FMC (R-2 = 0.04 and R-2 = 0.02, P < 0.0001). Resting diameter showed a stronger association with FMD but not with L-FMC (R-2 = 0.11, P < 0.0001 and R-2 = 0.005, P = 0.09). Analysis with generalized additive models showed that age, sex and presence and extent of coronary artery disease were strongly related to both endothelial function measures (P < 0.001 for both), but they explained only 12.4% and 10.1% of the variance in L-FMC and FMD. When the corresponding changes in blood flow were added to these statistical models, the % of variance explained raised to 20.4% and 17.7% for L-FMC and FMD. L-FMC was a strong predictor of FMD even after correction for the changes in blood flow. DISCUSSION: Changes in blood flow are the most important determinants of both L-FMC and FMD. These observations support the concept that both FMD and L-FMC measure endothelium-dependent, shear-induced, vasomotion.
引用
收藏
页码:255 / 265
页数:11
相关论文
共 50 条
  • [11] Flow-mediated dilation: Just a marker of local shear stress?
    Laclaustra, M
    Kaski, JC
    Frangi, AF
    HYPERTENSION, 2005, 45 (03) : E11 - E11
  • [12] Flow-Mediated Dilation (FMD) and Peripheral Endothelial Function Assessment
    Shechter, Michael
    JOURNAL OF VASCULAR RESEARCH, 2019, 56 : 100 - 100
  • [13] Measurement of flow-mediated constriction complements flow-mediated dilation in the prediction of coronary artery disease
    Muxel, S.
    Fasola, F.
    Radmacher, M. C.
    Jabs, A.
    Munzel, T.
    Parker, J. D.
    Gori, T.
    EUROPEAN HEART JOURNAL, 2010, 31 : 826 - 827
  • [14] Shear stress and flow-mediated dilation: all shear responses are not created equally
    Widlansky, Michael E.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 296 (01): : H31 - H32
  • [15] Proper "normalization" of flow-mediated dilation for shear
    Harris, Ryan A.
    Padilla, Jaume
    JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (03) : 1108 - 1108
  • [16] Blood flow simulation during flow-mediated dilation
    Asami, Naoya
    Yamazaki, Yoichi
    Kamiyama, Yoshimi
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2018, 101 (08) : 19 - 26
  • [17] Blood flow simulation during flow-mediated dilation
    Asami N.
    Yamazaki Y.
    Kamiyama Y.
    IEEJ Transactions on Electronics, Information and Systems, 2018, 138 (03) : 221 - 227
  • [18] Blood Flow Patterns during Flow-Mediated Dilation
    Morales-Acuna, Francisco
    Valencia, Carolina
    Gurovich, Alvaro N.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 489 - 489
  • [19] Evaluation of endothelial dysfunction: Flow-mediated dilation
    Korkmaz, Hasan
    Onalan, Orhan
    ENDOTHELIUM-JOURNAL OF ENDOTHELIAL CELL RESEARCH, 2008, 15 (04): : 157 - 163
  • [20] Flow-mediated dilation shows impaired endothelial function in patients with mastocytosis
    Bucci, Tommaso
    Parente, Roberta
    De Feo, Giulia
    Cardamone, Chiara
    Triggiani, Massimo
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2019, 144 (04) : 1106 - 1111