Three Dimensional Image Guided Extrapolation for Cone-Beam CT Image Reconstruction

被引:0
|
作者
Nett, Brian [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
关键词
Cone-beam CT; truncation; wide coverage; FIELD-OF-VIEW; ALGORITHM; EXTEND;
D O I
10.1117/12.2043609
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In cone-beam CT the range of projection views measured for each given image voxel is spatially variant. In the corners of the image volume there is less projection data available to be used by the image reconstruction algorithm, due to data truncation in the z direction (i.e. along the scanner axis). Given the desire to increase the fraction of the voxels which may be reconstructed from a given scan there is a desire to incorporate some extrapolated data into the image reconstruction procedure. In this work one approach is described which consists of a two-pass procedure where the first pass image reconstruction is performed over a larger extent in the z direction, a non-linear transform is applied to the initial reconstruction and a forward projection is applied in order to estimate the extrapolated image data. Initial results are presented which compare the method to zeroth order extrapolation and demonstrate that improvement in the reconstruction of the corner regions with a simple numerical phantom and with anatomical phantom data from a prototype wide coverage CT system.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Cone-beam image reconstruction by moving frames
    Yang, XC
    Horn, BKP
    COMPUTER VISION AND MATHEMATICAL METHODS IN MEDICAL AND BIOMEDICAL IMAGE ANALYSIS, 2004, 3117 : 35 - 47
  • [22] Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts
    Gomi, T.
    Koshida, K.
    Miyati, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (06) : 398 - 406
  • [23] Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy
    Cho, Seungryong
    Pearson, Erik
    Pelizzari, Charles A.
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2009, 36 (04) : 1184 - 1192
  • [24] Three-dimensional image analysis of a head of the giant panda by the cone-beam type CT
    Endo, H
    Komiya, T
    Narushima, E
    Suzuki, N
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2002, 64 (12): : 1153 - 1155
  • [25] Cone-beam CT: Applications in image-guided external beam radiotherapy and brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, GE
    Wong, JW
    Martinez, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2044 - 2044
  • [26] Image Quality QA for Three Radiotherapy Cone-Beam CT Systems
    Doemer, A.
    Perera, H.
    Gingold, E.
    Liu, H.
    Fu, L.
    Harrison, A.
    Yu, Y.
    Xiao, Y.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [27] Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration
    Kearney, V.
    Gu, X.
    Chen, S.
    Jiang, L.
    Liu, H.
    Chiu, T.
    Yordy, J.
    Nedzi, L.
    Mao, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 500 - 500
  • [28] Image artifact in dental cone-beam CT
    Katsumata, A
    Hirukawa, A
    Noujeim, M
    Okumura, S
    Naitoh, M
    Fujishita, M
    Ariji, E
    Langlais, RP
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 101 (05): : 652 - 657
  • [29] Comparison of a portable cone-beam device to conventional CT for image guided therapy
    Chow, P
    Mitschke, M
    Tenn, S
    Wink, N
    Cagnon, C
    Solberg, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1722 - 1722
  • [30] Towards optimization of megavoltage cone-beam CT for image-guided radiotherapy
    Pang, G
    O'Brien, P
    Mei, X
    Tambasco, M
    Yeboah, C
    Beachey, D
    Rowlands, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S623 - S623