Mixed-mode fabric phase sorptive extraction of multiple tetracycline residues from milk samples prior to high performance liquid chromatography-ultraviolet analysis

被引:34
|
作者
Agadellis, Efstratios [1 ]
Tartaglia, Angela [1 ,2 ]
Locatelli, Marcello [2 ]
Kabir, Abuzar [3 ]
Furton, Kenneth G. [3 ]
Samanidou, Victoria [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, Thessaloniki 54124, Greece
[2] Univ G dAnnunzio, Dept Pharm, Via Vestini 31, I-66100 Chieti, Italy
[3] Florida Int Univ, Int Forens Res Inst, Dept Chem & Biochem, Miami, FL 33199 USA
关键词
Fabric phase sorptive extraction; Sample preparation; Sol-gel mixed mode strong cation exchanging sorbent; Microextraction; Milk analysis; BOVINE-MILK; WATER; OXYTETRACYCLINE; COLUMN; SPECTROMETRY; ANTIBIOTICS; DOXYCYCLINE; VALIDATION; TANDEM;
D O I
10.1016/j.microc.2020.105437
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a new extraction mode of classical fabric phase sorptive extraction (FPSE), namely mixed-mode strong cation exchanging FPSE is presented and evaluated for the first time for the determination of tetracycline residues in milk, after protein precipitation. FPSE is a microextraction technique characterized by high chemically stable sorbent, higher analyte retention capacity and faster analyte diffusion capability, where the target analytes interact with the extraction sorbent during the pre-treatment process via a plethora of intermolecular/interionic interactions exerted by different functional moieties implanted on the sponge-like porous sol-gel sorbent network. Subsequently, the selectively retained analytes are eluted using a small volume of solvent system. A novel extraction membrane containing sol-gel C-18/propyl sulfonic acid, a mixed mode sorbent consisting of neutral, C-18 and strong cation exchanger, propyl sulfonic acid (C3H6SO3-) coated on 100% cotton cellulose fabric substrate was designed, synthesized, characterized and evaluated for the selective isolation of four tetracycline antibiotic residues from milk samples. For quantitative analysis, high performance liquid chromatography coupled with a UV detector (at 350 nm) was used. The method was validated according to the 2002/657/EC decision with regards to linearity, selectivity, stability, limits of detection and quantitation (LOD/LOQ), decision limit, detection capability, trueness, precision and ruggedness, according to the Youden's test. Recoveries ranged between 88.9 and 122.4%, while the LOD and LOQ were obtained at 15 mu g kg(-1) and 50 mu g kg(-1), respectively. Finally, the composite analytical method was applied to monitor the presence of residual tetracyclines in milk samples purchased from a local Greek market.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] An improved fabric phase sorptive extraction method for the determination of five selected antidepressant drug residues in human blood serum prior to high performance liquid chromatography with diode array detection
    Zilfidou, Eirini
    Kabir, Abuzar
    Furton, Kenneth G.
    Samanidou, Victoria
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1125
  • [22] An Improved Stir Fabric-Phase Sorptive Extraction Combined with Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Analysis for the Determination of 48 Pesticide Residues in Vegetable Samples
    Chen, Weiwei
    Mei, Yong
    Peng, Siya
    Li, Xuesheng
    FOOD ANALYTICAL METHODS, 2022, 15 (04) : 1011 - 1025
  • [23] Application of mixed-mode ultra high performance liquid chromatography to forensic drug analysis
    Clyde, Cassandra
    Blake, Samantha
    Obrien, Stacey
    Igwilo, Ihuoma
    Lurie, Ira S.
    ANALYTICAL METHODS, 2015, 7 (23) : 9763 - 9772
  • [24] Determination of Tetracycline Residues in Milk by On-line Coupling of Restricted Access Material Solid Phase Extraction with High Performance Liquid Chromatography
    Yang Xu
    Liu Mei-Jiao
    Lin Shen
    Xu Dan
    Dong Xiang-Chao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (01) : 146 - 151
  • [25] Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples
    Hu, Cong
    He, Man
    Chen, Beibei
    Zhong, Cheng
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 21 - 30
  • [26] Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection
    Fan, Wenying
    He, Man
    You, Linna
    Zhu, Xuewei
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 1 - 9
  • [27] Preparation of mixed-mode stationary phase for separation of peptides and proteins in high performance liquid chromatography
    Alharthi, Sarah
    Ali, Ashraf
    Iqbal, Muzaffar
    Ibrar, Aliya
    Ahmad, Bashir
    Nisa, Sobia
    Mabood, Fazal
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [28] Preparation of mixed-mode stationary phase for separation of peptides and proteins in high performance liquid chromatography
    Sarah Alharthi
    Ashraf Ali
    Muzaffar Iqbal
    Aliya Ibrar
    Bashir Ahmad
    Sobia Nisa
    Fazal Mabood
    Scientific Reports, 12 (1)
  • [29] Mixed micelle-cloud point extraction for the analysis of penicillin residues in bovine milk by high performance liquid chromatography
    Kukusamude, Chunyapuk
    Santalad, Apichai
    Boonchiangma, Suthasinee
    Burakham, Rodjana
    Srijaranai, Supalax
    Chailapakul, Orawon
    TALANTA, 2010, 81 (1-2) : 486 - 492
  • [30] The potential of three different adsorbents in solid-phase extraction of antihistaminic and antimigraine drugs from water samples using ultra-high-performance liquid chromatography-ultraviolet analysis
    Jebali, Sami
    Labidi, Aymen
    Ben Sghaier, Rafika
    Latrous, Latifa
    Megriche, Adel
    SEPARATION SCIENCE PLUS, 2024, 7 (02)