Inverting pupil illumination from resist-based measurements

被引:1
|
作者
Percin, Gokhan [1 ]
Sezginer, Apo [1 ]
Zach, Franz X. [1 ]
机构
[1] Invarium Inc, 1754 Technol Dr,Suite 117, San Jose, CA 95110 USA
来源
关键词
pupil; illumination; pupil fill; partial coherence; beam intensity profile; process and proximity compensation; lithography; stepper;
D O I
10.1117/12.656495
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Computational models used in process and proximity compensation require accurate description of the pupil illumination function of the lithography projector. Traditional top-hat approximation for pupil illumination function is no longer sufficient to meet stringent CD control requirements of low-k1 applications. The pupil illumination profile can change across the exposure field, contributing to across-field linewidth variation. We present a measurement of the pupil illumination based on exposing pinhole patterns on a wafer at different dose and defocus settings, and processing SEM images of patterns printed in photoresist. The fundamental principle of the method is Abbe's formulation of image formation: the intensity-image formed in resist is an incoherent, linear superposition of images each one of which is formed by illuminating the photomask by a single plane-wave. A single plane-wave that is incident on the photomask maps to a single point in the Fourier-transform aperture of the illuminator. The pupil-fill of the illuminator is obtained from SEM images by a model-based method consisting of these steps: First, resist edges in the SEM images are detected by an edge detection algorithm based on Perona-Malik diffusion. Coordinates of the points on the resist edge are obtained with respect to a reference ruler. The image intensity at any resist edge is equal to the dose-to-clear. This provides an equation for the image intensity at each point on the edge of a pinhole image. Multiple values of dose and defocus, and multiple points on each resist edge provide a large system of equations. The result of the inversion for a 193nm 0.75 NA stepper with sigma=0.55/0.85 annular illumination at five exposure field locations is presented. The CD difference between the nominal top-hat illumination and the inverted illumination was up to 1.8 nm for 1:1 line and space features ranging from 100nm to 300nm. Variation of the illumination along the long-dimension of the slit of the scanner caused 0.6 nm of CD variation for the same 1:1 dense lines.
引用
收藏
页码:U2304 / U2314
页数:11
相关论文
共 50 条
  • [31] Variations of aerosol microstructure under the effect of smokes as assessed from the results of inverting the data of spectral optical measurements
    Makienko, E. V.
    Kabanov, D. M.
    Rakhimov, R. F.
    Sakerin, S. M.
    THIRTEENTH JOINT INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS/ATMOSPHERIC PHYSICS, 2006, 6522
  • [32] Pupil size measurements with a multifunctional aberrometer/coherence interferometer/tomographer and two infrared-based pupillometers
    Davidova, Petra
    Biller, Marvin
    Ademmer, Vanessa
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (06): : 631 - 636
  • [33] Evaluating the Influence of Room Illumination on Camera-Based Physiological Measurements for the Assessment of Screen-Based Media
    Williams, Joseph
    Francombe, Jon
    Murphy, Damian
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [34] Characterization of Eye Gaze and Pupil Diameter Measurements from Remote and Mobile Eye-Tracking Devices
    Lolatto, Riccardo
    Rocco, Giulia
    Mustoni, Riccardo
    Maninetti, Chiara
    Pastura, Riccardo
    Pigazzini, Andrea
    Barbieri, Riccardo
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 201 - 208
  • [35] 193nm resist deprotection study from outgassing measurements by TD-GCMS/FID
    Tiron, Raluca
    Derrough, Samir
    Fontaine, Herve
    Cetre, Sylviane
    Perret, Damien
    Thackeray, James W.
    Paniez, Patrick
    26TH EUROPEAN MASK AND LITHOGRAPHY CONFERENCE, 2010, 7545
  • [36] Outdoor three-dimensional shape measurements using laser-based structured illumination
    Schaffer, Martin
    Grosse, Marcus
    Harendt, Bastian
    Kowarschik, Richard
    OPTICAL ENGINEERING, 2012, 51 (09)
  • [37] Method of inverting wavefront phase from far-field spot based on deep learning
    Zhang Y.
    He Y.
    Ning Y.
    Sun Q.
    Li J.
    Xu X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (08):
  • [38] An alternative illumination source based on LEDs for PIV measurements on human swimmers-A feasibility study
    Hochstein, Stefan
    Jakupov, Anvar
    Schmollack, Jens-Uwe
    Sporer, Daniel
    Wank, Veit
    Blickhan, Reinhard
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 88
  • [39] Comparison of illumination geometry for lifetime-based measurements in whole-body preclinical imaging
    Sinsuebphon, Nattawut
    Rudkouskaya, Alena
    Barroso, Margarida
    Intes, Xavier
    JOURNAL OF BIOPHOTONICS, 2018, 11 (10)
  • [40] Cosine Lobe Based Relighting from Gradient Illumination Photographs
    Fyffe, Graham
    Wilson, Cyrus A.
    Debevec, Paul
    2009 CONFERENCE FOR VISUAL MEDIA PRODUCTION: CVMP 2009, 2009, : 100 - 108