Microfluidic paper-based analytical device for photoelectrochemical immunoassay with multiplex signal amplification using multibranched hybridization chain reaction and PdAu enzyme mimetics

被引:64
|
作者
Lan, Feifei [1 ]
Sun, Guoqiang [1 ]
Liang, Linlin [1 ]
Ge, Shenguang [1 ,2 ]
Yan, Mei [1 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Photoelectrochemical immunoassay; Multibranched hybridization chain reaction; PdAu enzyme mimetics; Microfluidic paper-based analytical device; CDS QUANTUM DOTS; HORSERADISH-PEROXIDASE; BI2S3; NANORODS; ASCORBIC-ACID; IMMUNOSENSOR; CDTE; NANOCRYSTALS; ELECTRODE; STRATEGY; ANTIBODY;
D O I
10.1016/j.bios.2015.12.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Combining multibranched hybridization chain reaction (mHCR), the photoelectrochemical (PEC) immunosensor was fabricated with a microfluidic paper-based analytical devices using different sizes of CdTe quantum dots (QDs) sensitized flower-like 3D ZnO superstructures as photoactive materials. Firstly, 4-aminothiophenol (PATP) functioned ZnO was anchored on gold-paper working electrode. With the aid of PATP, large-sized CdTe-COOH QDs (QDs1) were conjugated onto the ZnO surface because of the formation of a strong bond (Zn-S) between the thiol of PATP molecule and the ZnO, and the remaining amino group formed an amide bond with carboxylic acid group capping CdTe. Then the small-sized CdTe-NH2 QDs (QDs2) were modified on the QDs1 by forming amide bond, which leaded to a very strong photocurrent response because of the formation of cosensitized structure. The designed mHCR produced long products with multiple branched arms, which could attached multiple PdAu nanoparticles and catalyze the oxidation of hydroquinone (HQ) using H2O2 as anoxidant. Double strands DNA with multiple branched arms (mdsDNA) was formed by mHCR. In the presence of carcinoembryonic antigen (CEA), PdAu-mdsDNA conjugates-labeled CEA antibody was captured. The concentrations of CEA were measured through the decrease in photocurrent intensity resulting from the increase in steric hindrance of the immunocomplex and the polymeric oxidation product of HQ. In addition, the oxidation product of HQ deposited on the as-obtained electrode, which could efficiently inhibit the photoinduced electron transfer. Under optimal conditions, the PEC immunosensor exhibited excellent analytical performance: the detection range of CEA was from 0.001 to 90 ng mL(-1) with low detection limit of 0.33 pg mL(-1). The as-obtained immunosensor exhibited excellent precision, prominent specificity, acceptable stability and reproducibility, and could be used for the detection of CEA in real samples. The proposed assay opens a promising platform of clinical immunoassay for other biomolecules. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [41] Speciation of inorganic arsenic in aqueous samples using a novel hydride generation microfluidic paper-based analytical device (µPAD)
    Mason E. Bonacci
    M. Inês G. S. Almeida
    Yanlin Zhang
    Spas D. Kolev
    Microchimica Acta, 2022, 189
  • [42] Development of a one-step analysis method for several amino acids using a microfluidic paper-based analytical device
    Kugimiya, Akimitsu
    Wakimoto, Sho
    Kohda, Jiro
    Nakano, Yasuhisa
    Takano, Yu
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [43] Enzyme-free hybridization chain reaction-based signal amplification strategy for the sensitive detection of Staphylococcus aureus
    Tang, Jie
    Wang, Zefeng
    Zhou, Jiaqi
    Lu, Qiujun
    Deng, Le
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 215 : 41 - 47
  • [44] A cytometric bead assay for sensitive DNA detection based on enzyme-free signal amplification of hybridization chain reaction
    Ren, Wei
    Liu, Hongmei
    Yang, Wenxia
    Fan, Yunlong
    Yang, Lang
    Wang, Yucong
    Liu, Chenghui
    Li, Zhengping
    BIOSENSORS & BIOELECTRONICS, 2013, 49 : 380 - 386
  • [45] Paper-Based Multiplex Surface-Enhanced Raman Scattering Detection Using Polymerase Chain Reaction Probe Codification
    Kim, Eun Ju
    Kim, Hanbi
    Park, Eunkyoung
    Kim, Taekyung
    Chung, Doo Ryeon
    Choi, Young-Man
    Kang, Minhee
    ANALYTICAL CHEMISTRY, 2021, 93 (08) : 3677 - 3685
  • [46] Fabrication of Miniaturized Microfluidic Paper-Based Analytical Devices for Sandwich Enzyme-Linked Immunosorbent Assays using INKJET Printing
    Le, N. N.
    Phan, H. C. T.
    Dang, D. M. T.
    Dang, C. M.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2021, 57 (02) : 257 - 261
  • [47] Determination of Nickel and Cobalt in Cosmetic Products Marketed in Iraq Using Spectrophotometric and Microfluidic Paper-based Analytical Device (μPADs) Platform
    Abdulkareem, Ekhlas A.
    Abdulsattar, Jwan O.
    BAGHDAD SCIENCE JOURNAL, 2022, 19 (06) : 1286 - 1296
  • [48] Simultaneous colorimetric detection of metallic salts contained in low explosives residue using a microfluidic paper-based analytical device (μPAD)
    Chabaud, Kathryn R.
    Thomas, Jennifer L.
    Torres, Michelle N.
    Oliveira, Sheila
    McCord, Bruce R.
    FORENSIC CHEMISTRY, 2018, 9 : 35 - 41
  • [49] Fabrication of Miniaturized Microfluidic Paper-Based Analytical Devices for Sandwich Enzyme-Linked Immunosorbent Assays using INKJET Printing
    N. N. Le
    H. C. T. Phan
    D. M. T. Dang
    C. M. Dang
    Applied Biochemistry and Microbiology, 2021, 57 : 257 - 261
  • [50] Microfluidic Paper-based Analytical Device for Quantification of Lead Using Reaction Band-length for Identification of Bullet Hole and Its Potential for Estimating Firing Distance
    Buking, Supatana
    Saetear, Phoonthawee
    Tiyapongpattana, Warawut
    Uraisin, Kanchana
    Wilairat, Prapin
    Nacapricha, Duangjai
    Ratanawimarnwong, Nuanlaor
    ANALYTICAL SCIENCES, 2018, 34 (01) : 83 - 89