Microfluidic paper-based analytical device for photoelectrochemical immunoassay with multiplex signal amplification using multibranched hybridization chain reaction and PdAu enzyme mimetics

被引:64
|
作者
Lan, Feifei [1 ]
Sun, Guoqiang [1 ]
Liang, Linlin [1 ]
Ge, Shenguang [1 ,2 ]
Yan, Mei [1 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Photoelectrochemical immunoassay; Multibranched hybridization chain reaction; PdAu enzyme mimetics; Microfluidic paper-based analytical device; CDS QUANTUM DOTS; HORSERADISH-PEROXIDASE; BI2S3; NANORODS; ASCORBIC-ACID; IMMUNOSENSOR; CDTE; NANOCRYSTALS; ELECTRODE; STRATEGY; ANTIBODY;
D O I
10.1016/j.bios.2015.12.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Combining multibranched hybridization chain reaction (mHCR), the photoelectrochemical (PEC) immunosensor was fabricated with a microfluidic paper-based analytical devices using different sizes of CdTe quantum dots (QDs) sensitized flower-like 3D ZnO superstructures as photoactive materials. Firstly, 4-aminothiophenol (PATP) functioned ZnO was anchored on gold-paper working electrode. With the aid of PATP, large-sized CdTe-COOH QDs (QDs1) were conjugated onto the ZnO surface because of the formation of a strong bond (Zn-S) between the thiol of PATP molecule and the ZnO, and the remaining amino group formed an amide bond with carboxylic acid group capping CdTe. Then the small-sized CdTe-NH2 QDs (QDs2) were modified on the QDs1 by forming amide bond, which leaded to a very strong photocurrent response because of the formation of cosensitized structure. The designed mHCR produced long products with multiple branched arms, which could attached multiple PdAu nanoparticles and catalyze the oxidation of hydroquinone (HQ) using H2O2 as anoxidant. Double strands DNA with multiple branched arms (mdsDNA) was formed by mHCR. In the presence of carcinoembryonic antigen (CEA), PdAu-mdsDNA conjugates-labeled CEA antibody was captured. The concentrations of CEA were measured through the decrease in photocurrent intensity resulting from the increase in steric hindrance of the immunocomplex and the polymeric oxidation product of HQ. In addition, the oxidation product of HQ deposited on the as-obtained electrode, which could efficiently inhibit the photoinduced electron transfer. Under optimal conditions, the PEC immunosensor exhibited excellent analytical performance: the detection range of CEA was from 0.001 to 90 ng mL(-1) with low detection limit of 0.33 pg mL(-1). The as-obtained immunosensor exhibited excellent precision, prominent specificity, acceptable stability and reproducibility, and could be used for the detection of CEA in real samples. The proposed assay opens a promising platform of clinical immunoassay for other biomolecules. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [1] Microfluidic Paper-Based Analytical Device for Sensitive Detection of Peptides Based on Specific Recognition of Aptamer and Amplification Strategy of Hybridization Chain Reaction
    Ma, Chao
    Liu, Haiyun
    Zhang, Lina
    Li, Li
    Yan, Mei
    Yu, Jinghua
    Song, Xianrang
    CHEMELECTROCHEM, 2017, 4 (07): : 1744 - 1749
  • [2] Signal Amplification in a Microfluidic Paper-based Analytical Device (μ-PAD) by Confinement of the Fluidic Flow
    Choi, Seoyeon
    Lee, Jung-Hyun
    Kwak, Bong Seop
    Kim, Young Woo
    Lee, Joon Sang
    Choi, Jong-Soon
    Jung, Hyo-Il
    BIOCHIP JOURNAL, 2015, 9 (02) : 116 - 123
  • [3] Signal amplification in a microfluidic paper-based analytical device (µ-PAD) by confinement of the fluidic flow
    Seoyeon Choi
    Jung-Hyun Lee
    Bong Seop Kwak
    Young Woo Kim
    Joon Sang Lee
    Jong-Soon Choi
    Hyo-Il Jung
    BioChip Journal, 2015, 9 : 116 - 123
  • [4] An ultrasensitive and universal photoelectrochemical immunoassay based on enzyme mimetics enhanced signal amplification
    Wang, Guang-Li
    Shu, Jun-Xian
    Dong, Yu-Ming
    Wu, Xiu-Ming
    Li, Zai-Jun
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 283 - 289
  • [5] Photoelectrochemical sensor for pentachlorophenol on microfluidic paper-based analytical device based on the molecular imprinting technique
    Sun, Guoqiang
    Wang, Panpan
    Ge, Shenguang
    Ge, Lei
    Yu, Jinghua
    Yan, Mei
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 97 - 103
  • [6] Origami Paper-Based Immunoassay Device with CRISPR/Cas12a Signal Amplification
    Suzuki, Hikaru
    Tong, Guodong
    Nath, Pabitra
    Hiruta, Yuki
    Citterio, Daniel
    ACS SENSORS, 2025, 10 (03): : 1811 - 1821
  • [7] Multilayer microfluidic paper-based analytical device using pyrolyzed paper for electrochemical detection
    Evans, Elizabeth
    Giuliani, Jason
    da Costa, Eric Tavares
    Garcia, Carlos
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [8] Paper-based electrochemiluminescence telomerase activity detection using hybridization chain reaction and CRISPR/Cas12a dual signal amplification
    Zhang, Yun
    Gao, Liang
    Shi, Zhe
    Wu, Qiong
    Miao, Xiangmin
    BIOELECTROCHEMISTRY, 2025, 164
  • [9] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Taghizadeh-Behbahani, Maryam
    Hemmateenejad, Bahram
    Shamsipur, Mojtaba
    CHEMICAL PAPERS, 2018, 72 (05) : 1239 - 1247
  • [10] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Maryam Taghizadeh-Behbahani
    Bahram Hemmateenejad
    Mojtaba Shamsipur
    Chemical Papers, 2018, 72 : 1239 - 1247