Fourier-Domain OCT Imaging Processor with Improved Memory Efficiency

被引:0
|
作者
Tang, Song-Nien [1 ]
Liao, Jen-Chien [1 ]
Chiu, Chen-Kai [1 ]
Ku, Pei-Tong [1 ]
Lou, Chi-Ho [1 ]
Li, Yu-Ci [1 ]
机构
[1] Chung Yuan Christian Univ, Informat & Comp Engn, Taoyuan, Taiwan
关键词
optical coherence tomography; OCT; Fourierdomain; FDOCT; imaging; memory efficiency;
D O I
10.1109/APCCAS51387.2021.9687712
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a display processing unit for the image formation of the Fourier-domain optical coherence tomography (FDOCT) system. Using the proposed design, the FDOCT imaging operations involving the re-sampler, the real-valued fast Fourier transform (RFFT) and the image display processing can be efficiently performed using a hardware processor, allowing high-frame-rate OCT image display with the direct generation of gray-scale image data. Compared to previous works, the proposed design improved the memory efficiency in terms of the RAM size, the control complexity and the logarithm table size for the re-sampler, the RFFT and the display processing units, respectively. The presented FDOCT imaging processor was verified using a SoC-FPGA platform based on the software-hardware codesign with accesses of the raw data obtained from the FDOCT front-end equipment.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [21] In-vitro observation of cartilage-degeneration progression by Fourier-domain OCT
    Marx, Ulrich
    Schmitt, Robert
    Nebelung, Sven
    Tingart, Markus
    Luering, Christian
    Rath, Bjoern
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS X, 2012, 8214
  • [22] Optical aperture synthesis imaging with fractional Fourier-domain filtering
    Jiang, Yuesong
    Zhang, Jingjing
    He, Yuntao
    Wang, Haiyang
    Wang, Jing
    Zhang, Jun
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (03) : 295 - 302
  • [23] Mesh adaptation technique for Fourier-domain fluorescence lifetime imaging
    Soloviev, Vadim Y.
    MEDICAL PHYSICS, 2006, 33 (11) : 4176 - 4183
  • [24] Towards automatic calibration of Fourier-Domain OCT for robot-assisted vitreoretinal surgery
    Liu, Xuan
    Balicki, Marcin
    Taylor, Russell H.
    Kang, Jin U.
    OPTICS EXPRESS, 2010, 18 (23): : 24331 - 24343
  • [25] Ganglion Cell Complex Analysis With Fourier-Domain OCT: Reproducibility and Diagnostic Accuracy in Glaucoma
    Michelessi, M.
    Oddone, F.
    Centofanti, M.
    Tanga, L.
    Lotito, S.
    Roberti, G.
    Tranchina, L.
    Manni, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [26] Analysis of attenuation coefficient estimation in Fourier-domain OCT of semi-infinite media
    Ghafaryasl, Babak
    Vermeer, Koenraad A.
    Kalkman, Jeroen
    Callewaert, Tom
    de Boer, Johannes F.
    Van Vliet, Lucas J.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (11) : 6093 - 6107
  • [27] Common approach for compensation of axial motion artifacts in swept-source OCT and dispersion in Fourier-domain OCT
    Hillmann, Dierck
    Bonin, Tim
    Luehrs, Christian
    Franke, Gesa
    Hagen-Eggert, Martin
    Koch, Peter
    Huettmann, Gereon
    OPTICS EXPRESS, 2012, 20 (06): : 6761 - 6776
  • [28] Pixel-based speckle adjustment for noise reduction in Fourier-domain OCT images
    Zhang, Anqi
    Xi, Jiefeng
    Sun, Jitao
    Li, Xingde
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1721 - 1740
  • [29] The Effect of Image Quality on the Reliability of Nerve Fiber Layer Measurements with Fourier-Domain OCT
    Tan, Ou
    Zhang, Xinbo
    Loewen, Nils
    Schuman, Joel
    Greenfield, David
    Varma, Rohit
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [30] Retinal nerve fiber layer analysis in RP patients using Fourier-domain OCT
    Walia, Saloni
    Fishman, Gerald A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3525 - 3528