A Systematic Review and Meta-Analysis of the Direct Comparison of Second-Generation Cryoballoon Ablation and Contact Force-Sensing Radiofrequency Ablation in Patients with Paroxysmal Atrial Fibrillation

被引:10
|
作者
Waranugraha, Yoga [1 ]
Rizal, Ardian [2 ]
Yuniadi, Yoga [3 ]
机构
[1] Univ Brawijaya, Univ Brawijaya Hosp, Fac Med, Dept Cardiol & Vasc Med, Malang 65142, Indonesia
[2] Univ Brawijaya, Dr Saiful Anwar Gen Hosp, Fac Med, Dept Cardiol & Vasc Med, Malang 65111, Indonesia
[3] Univ Indonesia, Fac Med, Natl Cardiovasc Ctr Harapan Kita, Dept Cardiol & Vasc Med, Jakarta Barat 11420, Indonesia
来源
JOURNAL OF PERSONALIZED MEDICINE | 2022年 / 12卷 / 02期
关键词
paroxysmal atrial fibrillation; catheter ablation; second-generation cryoballoon ablation; contact force-sensing radiofrequency ablation; PULMONARY VEIN ISOLATION; CATHETER ABLATION; EFFICACY; TRIAL; OUTCOMES; IMPROVE; POINT;
D O I
10.3390/jpm12020298
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The superiority of second-generation cryoballoon (2G-CB) ablation versus contact force-sensing radiofrequency (CF-RF) ablation in patients with paroxysmal atrial fibrillation (AF) was assessed in this systematic review and meta-analysis. Freedom from atrial tachyarrhythmias (ATAs) (OR = 0.89; 95% confidence interval [CI] = 0.68 to 1.17; p = 0.41), freedom from AF (OR = 0.93; 95% CI = 0.65 to 1.35; p = 0.72), and acute pulmonary vein isolation (PVI) (OR = 1.17; 95% CI = 0.54 to 2.53; p = 0.70) between 2G-CB ablation and CF-RF ablation were not different. The procedure time for the 2G-CB ablation was shorter (MD = -18.78 min; 95% CI = -27.72 to -9.85 min; p < 0.01), while the fluoroscopy time was similar (MD = 2.66 min; 95% CI = -0.52 to 5.83 min; p = 0.10). In the 2G-CB ablation group, phrenic nerve paralysis was more common (OR = 5.74; 95% CI = 1.80 to 18.31; p = < 0.01). Regarding freedom from ATAs, freedom from AF, and acute PVI, these findings imply that 2G-CB ablation is not superior to CF-RF ablation in paroxysmal AF. Although faster than CF-RF ablation, 2G-CB ablation has a greater risk of phrenic nerve paralysis.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] A meta-analysis and cost-minimization analysis of cryoballoon ablation versus radiofrequency ablation for paroxysmal atrial fibrillation
    Nitta, Yoshimi
    Nishimura, Michiko
    Shibahara, Hidetoshi
    Yamane, Teiichi
    JOURNAL OF ARRHYTHMIA, 2024, 40 (04) : 802 - 814
  • [32] Safety and Efficacy of Radiofrequency versus Second-Generation Cryoballoon Ablation for Treatment of Atrial Fibrillation - A Meta-analysis of Current Evidence
    Pandya, Bhavi
    Parikh, Valay
    Kenigsberg, David
    O'Neill, Padraig Gearoid
    Koo, Charles H.
    Aryana, Arash
    Kowalski, Marcin
    CIRCULATION, 2016, 134
  • [33] Safety and Efficacy of Radiofrequency versus Second-Generation Cryoballoon Ablation for Treatment of Atrial Fibrillation - A Meta-analysis of Current Evidence
    Pandya, Bhavi
    Parikh, Valay
    Kenigsberg, David
    O'Neill, Padraig Gearoid
    Koo, Charles H.
    Aryana, Arash
    Kowalski, Marcin
    CIRCULATION, 2016, 134
  • [34] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Karim Benali
    Van Duc Lai
    Nefissa Hammache
    Isabelle Magnin-Poull
    Christian de Chillou
    Jean-Marc Sellal
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 931 - 940
  • [35] Second-Generation Cryoballoon Ablation in Persistent Atrial Fibrillation
    Hook, Bruce G.
    Elban-Hawy, Noha
    Chaudhry, Muqtada
    Silver, Jonathan S.
    Reynolds, Matthew R.
    Bosli, Lamia
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) : 590 - 591
  • [36] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Benali, Karim
    Lai, Van Duc
    Hammache, Nefissa
    Magnin-Poull, Isabelle
    de Chillou, Christian
    Sellal, Jean-Marc
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 931 - 940
  • [37] Comparison of higher-power and conventional power ablation of atrial fibrillation using contact force-sensing catheters: a systematic review and meta-analysis
    Cui, Luqian
    Chu, Yingjie
    Han, Yongmei
    Dong, Shujuan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 1 - 7
  • [38] Comparison of higher-power and conventional power ablation of atrial fibrillation using contact force-sensing catheters: a systematic review and meta-analysis
    Luqian Cui
    Yingjie Chu
    Yongmei Han
    Shujuan Dong
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 1 - 7
  • [39] Cryoballoon vs. radiofrequency contact force ablation for paroxysmal atrial fibrillation: a propensity score analysis
    Matta, Mario
    Anselmino, Matteo
    Ferraris, Federico
    Scaglione, Marco
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (04) : 141 - 147
  • [40] CRYOBALLOON ABLATION FOR THE TREATMENT OF ATRIAL FIBRILLATION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Patel, Nirav
    Shenoy, Abhishek
    Baker, William
    Makaryus, Amgad
    El-Sherif, Nabil
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 524 - 524