A Systematic Review and Meta-Analysis of the Direct Comparison of Second-Generation Cryoballoon Ablation and Contact Force-Sensing Radiofrequency Ablation in Patients with Paroxysmal Atrial Fibrillation

被引:10
|
作者
Waranugraha, Yoga [1 ]
Rizal, Ardian [2 ]
Yuniadi, Yoga [3 ]
机构
[1] Univ Brawijaya, Univ Brawijaya Hosp, Fac Med, Dept Cardiol & Vasc Med, Malang 65142, Indonesia
[2] Univ Brawijaya, Dr Saiful Anwar Gen Hosp, Fac Med, Dept Cardiol & Vasc Med, Malang 65111, Indonesia
[3] Univ Indonesia, Fac Med, Natl Cardiovasc Ctr Harapan Kita, Dept Cardiol & Vasc Med, Jakarta Barat 11420, Indonesia
来源
JOURNAL OF PERSONALIZED MEDICINE | 2022年 / 12卷 / 02期
关键词
paroxysmal atrial fibrillation; catheter ablation; second-generation cryoballoon ablation; contact force-sensing radiofrequency ablation; PULMONARY VEIN ISOLATION; CATHETER ABLATION; EFFICACY; TRIAL; OUTCOMES; IMPROVE; POINT;
D O I
10.3390/jpm12020298
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The superiority of second-generation cryoballoon (2G-CB) ablation versus contact force-sensing radiofrequency (CF-RF) ablation in patients with paroxysmal atrial fibrillation (AF) was assessed in this systematic review and meta-analysis. Freedom from atrial tachyarrhythmias (ATAs) (OR = 0.89; 95% confidence interval [CI] = 0.68 to 1.17; p = 0.41), freedom from AF (OR = 0.93; 95% CI = 0.65 to 1.35; p = 0.72), and acute pulmonary vein isolation (PVI) (OR = 1.17; 95% CI = 0.54 to 2.53; p = 0.70) between 2G-CB ablation and CF-RF ablation were not different. The procedure time for the 2G-CB ablation was shorter (MD = -18.78 min; 95% CI = -27.72 to -9.85 min; p < 0.01), while the fluoroscopy time was similar (MD = 2.66 min; 95% CI = -0.52 to 5.83 min; p = 0.10). In the 2G-CB ablation group, phrenic nerve paralysis was more common (OR = 5.74; 95% CI = 1.80 to 18.31; p = < 0.01). Regarding freedom from ATAs, freedom from AF, and acute PVI, these findings imply that 2G-CB ablation is not superior to CF-RF ablation in paroxysmal AF. Although faster than CF-RF ablation, 2G-CB ablation has a greater risk of phrenic nerve paralysis.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A systematic review and meta-analysis comparing second-generation cryoballoon and contact force radiofrequency ablation for initial ablation of paroxysmal and persistent atrial fibrillation
    Ravi, Venkatesh
    Poudyal, Abhushan
    Pulipati, Priyanjali
    Larsen, Timothy
    Krishnan, Kousik
    Trohman, Richard G.
    Sharma, Parikshit S.
    Huang, Henry D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (10) : 2559 - 2571
  • [2] Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation
    Squara, Fabien
    Zhao, Alexandre
    Marijon, Eloi
    Latcu, Decebal Gabriel
    Providencia, Rui
    Di Giovanni, Giacomo
    Jauvert, Gael
    Jourda, Francois
    Chierchia, Gian-Battista
    De Asmundis, Carlo
    Ciconte, Giuseppe
    Alonso, Christine
    Grimard, Caroline
    Boveda, Serge
    Cauchemez, Bruno
    Saoudi, Nadir
    Brugada, Pedro
    Albenque, Jean-Paul
    Thomas, Olivier
    EUROPACE, 2015, 17 (05): : 718 - 724
  • [3] Catheter ablation for paroxysmal atrial fibrillation: new generation cryoballoon or contact force sensing radiofrequency ablation?
    Nagy Zsofia
    Kis Zsuzsanna
    Som Zoltan
    Foldesi Csaba
    Kardos Attila
    ORVOSI HETILAP, 2016, 157 (22) : 849 - 854
  • [4] A Comparative Analysis of Radiofrequency Ablation with Contact Force Sensing and Second-Generation Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: A Study at the Najaf Cardiac Center
    Shekhani, Ali Hamadameen
    Talib, Ahmed Abdulkarim
    Mustafa, Muhammad Kareem
    MEDICINA BALEAR, 2024, 39 (04):
  • [5] Is Treatment for Paroxysmal Atrial Fibrillation With Second-generation Cryoballoon Ablation More Reproducible Than That With Contact Force Guided Radiofrequency Ablation?
    Tanaka, Nobuaki
    Inoue, Koichi
    Tanaka, Koji
    Ninomiya, Yuichi
    Hirao, Yuko
    Oka, Takafumi
    Okada, Masato
    Nakamaru, Ryo
    Inoue, Hiroyuki
    Koyama, Yasushi
    Okamura, Atsunori
    Iwakura, Katsuomi
    Fujii, Kenshi
    CIRCULATION, 2017, 136
  • [6] Comparison of Cryoballoon and Contact Force-Sensing Radiofrequency Ablation for Persistent Atrial Fibrillation in Clinical Practice
    Kobori, Atsushi
    Sasaki, Yasuhiro
    Pak, Misun
    Ishikura, Masahiro
    Murai, Ryosuke
    Okada, Taiji
    Toyota, Toshiaki
    Taniguchi, Tomohiko
    Kim, Kitae
    Ehara, Natsuhiko
    Kinoshita, Makoto
    Kihara, Yasuki
    Furukawa, Yutaka
    CIRCULATION JOURNAL, 2022, 86 (02) : 290 - 298
  • [7] A Meta-Analysis of the Comparative Efficacy and Safety of Ablation for Atrial Fibrillation With the Use of Contact Force Sensing Catheter and second-generation Cryoballoon
    Lv Wenkui
    Zhou, Xianhui
    Tang, Baopeng
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C110 - C110
  • [8] Second-generation cryoballoon vs. contact-force sensing radiofrequency catheter ablation in atrial fibrillation: a meta-analysis of randomized controlled trials
    Yang Wang
    Wei Wang
    Jianming Yao
    Lianghua Chen
    Shaolei Yi
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 9 - 19
  • [9] Second-generation cryoballoon vs. contact-force sensing radiofrequency catheter ablation in atrial fibrillation: a meta-analysis of randomized controlled trials
    Wang, Yang
    Wang, Wei
    Yao, Jianming
    Chen, Lianghua
    Yi, Shaolei
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (01) : 9 - 19
  • [10] Comparison of cryoballoon and radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis
    Kim, Jitae A.
    Chelu, Mihail G.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (03) : 585 - 595