Calibration methods for vibration transducers and their uncertainties

被引:18
|
作者
Usuda, T [1 ]
Kurosawa, T [1 ]
机构
[1] Natl Res Lab Metrol, Tsukuba, Ibaraki 3058563, Japan
关键词
D O I
10.1088/0026-1394/36/4/17
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A primary calibration system for vibration transducers within the mid- to high-frequency range (20 Hz to 5 kHz) has been introduced at the National Research Laboratory of Metrology, Japan. We used a recently updated method described in the ISO (International Organization for Standardization) report FDIS 16063-11, called the sine-approximation method. The calibration system is also available for conventional methods such as fringe counting and minimum point, as described in International Standard ISO 5347-1. Each method is carried out simultaneously and the results are compared. Signal-processing procedures and the techniques used in the sine-approximation method (phase-unwrapping algorithm, uncertainty calculation and resolution of the A/D converter), are discussed. Relative deviations within 2 x 10(-3) for frequencies of 160 Hz and 800 Hz in the sine-approximation and conventional methods are obtained in the calibration. Problems with the system are also discussed.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 50 条
  • [21] The calibration of vibration sensors by laser-holographic methods
    Atavin, VG
    Kuranov, VV
    Romanenko, NN
    Khudyakov, YV
    Yurchik, EF
    MEASUREMENT TECHNIQUES, 2002, 45 (06) : 630 - 634
  • [22] The Calibration of Vibration Sensors by Laser-Holographic Methods
    V. G. Atavin
    V. V. Kuranov
    N. N. Romanenko
    Yu. V. Khudyakov
    E. F. Yurchik
    Measurement Techniques, 2002, 45 : 630 - 634
  • [23] ESTIMATION OF WEIGHT AND TORQUE ON BIT: ASSESSMENT OF UNCERTAINTIES, CORRECTION AND CALIBRATION METHODS
    Cayeux, Eric
    Skadsem, Hans Joakim
    33RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2014, VOL 5, 2014,
  • [24] ADVANCES IN MEASUREMENT METHODS AND REDUCTION OF MEASUREMENT UNCERTAINTIES ASSOCIATED WITH ANTENNA CALIBRATION
    ALEXANDER, MJ
    SALTER, MJ
    GENTLE, DG
    HOLLAND, KP
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (04) : 283 - 286
  • [25] Dynamic calibration methods for both transducers of ultra high and ultra low temperature
    Huang, JQ
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY, 2003, 5253 : 1 - 5
  • [26] Methods for the calibration of bone conduction transducers at frequencies from 5 to 20 kHz
    Remenschneider, Aaron K.
    Cheng, Jeffrey Tao
    Rosowski, John J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2022, 151 (05): : 2945 - 2966
  • [27] CALIBRATION OF ULTRASONIC PROBE TRANSDUCERS
    BRENDEL, K
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 59 : S27 - S27
  • [28] UNCONVENTIONAL RECIPROCITY CALIBRATION OF TRANSDUCERS
    RUDNICK, I
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (06): : 1923 - 1925
  • [29] RELATIVE CALIBRATION OF AE TRANSDUCERS
    EGLE, D
    YANG, S
    MATERIALS EVALUATION, 1986, 44 (09) : 26 - 26
  • [30] SELECTOR FOR THE CALIBRATION OF PIEZOELECTRIC TRANSDUCERS
    KRIVOSHEEV, IA
    BAKSHEEV, VG
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1982, 18 (03): : 170 - 171