The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand

被引:8
|
作者
Olek, Malgorzata [1 ]
Olczak, Piotr [1 ]
Kryzia, Dominik [2 ]
机构
[1] Cracow Univ Technol, Fac Environm Engn, Inst Thermal Engn & Air Protect, Warszawska 24, PL-31155 Krakow, Poland
[2] Polish Acad Sci, Mineral & Energy Econ Res Inst, Wybickiego 7, PL-31261 Krakow, Poland
关键词
D O I
10.1051/e3sconf/20161000139
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The popularity of solar collectors in Poland is still increasing. The correct location of the collectors and a relatively high density of solar radiation allow delivering heat even in spite of relatively low ambient temperature. Moreover, solar systems used for heating domestic heat water (DHW) in summer allow nearly complete elimination of conventional energy sources (e.g. gas, coal). That is why more and more house owners in Poland decide to install solar system installations. In Poland the most common types of solar collectors are flat plate collectors (FPC) and evacuated tube collectors with heat pipe (ETCHP); both were selected for the analysis. The heat demand related to the preparation of hot water, connected with the size of solar collectors' area, has been determined. The analysis includes FPC and ETCHP and heat demand of less than 10 000 kWh/year. Simulations were performed with the Matlab software and using data from atypical meteorological year (TMY). In addition, a 126 year period of measurements of insolation for Krakow has been taken into account. The HDKR model (Hay, Davis, Klucher, Reindl) was used for the calculation of solar radiation on the absorber surface. The monthly medium temperature of the absorber depends on the amount of solar system heat and on the heat demand. All the previously mentioned data were used to determine solar efficiency. Due to the fact that solar efficiency and solar system heat are connected, the calculations were made with the use of an iterative method. Additionally, the upper limit for monthly useful solar system heat is resulted from the heat demand and thus the authors prepared a model of statistical solar system heat deviations based on the Monte Carlo method. It has been found that an increase in the useful solar system heat in reference to the heat demand is associated with more than proportional increase in the sizes of the analyzed surfaces of solar collector types.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Economic feasibility of flat plate vs evacuated tube solar collectors in a combisystem
    Najera-Trejo, Mario
    Martin-Domiguez, Ignacio R.
    Escobedo-Bretado, Jorge A.
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2015), 2016, 91 : 477 - 485
  • [22] An examination of evacuated tube collectors in comparison to direct flow and heat pipe for the purpose of solar water heating
    Palanivel, Vijayakumar
    Munimathan, Arunkumar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 8686 - 8702
  • [23] The effect of different working fluids and internal geometries on the efficiency of evacuated tube heat pipe solar collectors
    Mukuna, Jean Gad
    Gryzagoridis, Jasson
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2020, 31 (04) : 16 - 25
  • [24] HEAT PIPES IN FLAT-PLATE SOLAR COLLECTORS
    BIENERT, WB
    WOLF, DA
    MECHANICAL ENGINEERING, 1977, 99 (03) : 102 - 102
  • [25] Heat enhancement in solar flat plate collectors - A review
    Raja, G. Abinicks
    Natarajan, Rajamurugu
    Gaikwad, Pratik R.
    Basil, Eleena
    Borse, Sahil D.
    Sundararaj, M.
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (03): : 773 - 789
  • [26] TECHNOLOGY OF SOLAR HEAT FLAT-PLATE COLLECTORS
    SAYIGH, AAM
    JOURNAL OF ENGINEERING SCIENCES, 1978, 4 (01): : 75 - 88
  • [27] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [28] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [29] Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate
    Ayompe, L. M.
    Duffy, A.
    Mc Keever, M.
    Conlon, M.
    McCormack, S. J.
    ENERGY, 2011, 36 (05) : 3370 - 3378
  • [30] Proof of guaranteed solar yields in solar thermal plants with flat plate and evacuated tube collectors
    Karandashev, Artem
    Eberhardt, Kay
    Gaspar, Paul
    Meißner, Rolf
    Euroheat and Power/Fernwarme International, 2022, 51 (7-8): : 24 - 31