Automatic generation of anatomy-based MLC fields in aperture-based IMRT

被引:14
|
作者
Beaulieu, F
Beaulieu, L
Tremblay, D
Lachance, B
Roy, R
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Ste Foy, PQ G1K 7P4, Canada
[2] Univ Quebec, Ctr Hosp, Dept Radio Oncol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Quebec, Ctr Hosp, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
关键词
anatomy-based MLC fields; aperture-based IMRT;
D O I
10.1118/1.1697670
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed an algorithm to automatically generate anatomy-based MLC fields. For each beam, a first field is adjusted to the projection of the target in a beam's eye view, allowing subsequent fields to be derived from this conformal field by removing the overlapping surface of each organ at risk, respectively. The projections are based on a surface sampling of the anatomical structures. On top of the MLC mechanical constraints, verification constraints are imposed on the MLC segments, in order to get reliable dosimetry using a commercial dose calculation engine. Thus, in each direction, the aperture's cross-section must be greater than a specified threshold, in our case 2 cm. Furthermore, junctions are not tolerated in order to avoid underdosage, for instance from the tongue-and-groove effect. The use of such MLC fields simplifies the verification process. The performance of the algorithm is illustrated for head and neck, thorax and prostate cases. Only a fraction of a second of CPU time is required to perform the segmentation for each beam. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:1539 / 1545
页数:7
相关论文
共 50 条
  • [21] Additively Manufactured Aperture-Based FSS
    Hook, Alexander
    Motes, Doyle T., III
    Morrow, Cody
    Donnell, Kristen M.
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [22] Additively Manufactured Aperture-based FSS
    Hook, Alexander
    Motes, Doyle T.
    Morrow, Cody
    Donnell, Kristen M.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 2024,
  • [23] Automatic Extraction of Mandibular Bone Geometry for Anatomy-based Synthetization of Radiographs
    Antila, Kari
    Lilja, Mikko
    Kalke, Martti
    Lotjonen, Jyrki
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 490 - +
  • [24] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [25] Couch and aperture-based correction in IGRT
    Scherer, P.
    Deutschmann, H.
    Steininger, P.
    Keuschnigg, P.
    Zechner, A.
    Koch, A. K.
    Sedlmayer, F.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S88 - S88
  • [26] Localized and propagating surface plasmon resonances in aperture-based third harmonic generation
    Nezami, Mohammadreza S.
    Gordon, Reuven
    OPTICS EXPRESS, 2015, 23 (25): : 32006 - 32014
  • [27] Development and evaluation of aperture-based complexity metrics using film and EPID measurements of static MLC openings
    Gotstedt, Julia
    Hauer, Anna Karlsson
    Back, Anna
    MEDICAL PHYSICS, 2015, 42 (07) : 3911 - 3921
  • [28] Synthetic aperture-based on-chip microscopy
    Wei Luo
    Alon Greenbaum
    Yibo Zhang
    Aydogan Ozcan
    Light: Science & Applications, 2015, 4 : e261 - e261
  • [29] Anatomy-based automatic detection and segmentation of major vessels in thoracic CTA images
    Zou, Xiaotao
    Liang, Jianming
    Wolf, Matthias
    Salganicoff, Marcos
    Krishnan, Arun
    Nadich, David P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S68 - S70
  • [30] Dynamic aperture-based solar loop segmentation
    Lee, Jong Kwan
    Newman, Timothy S.
    Gary, G. Allen
    7TH IEEE SOUTHWEST SYMPOSIUM ON IMAGE ANALYSIS AND INTERPRETATION, 2006, : 91 - +