Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty

被引:36
|
作者
Maezawa, K [1 ]
Nozawa, M [1 ]
Hirose, T [1 ]
Matsuda, K [1 ]
Yasuma, M [1 ]
Shitoto, K [1 ]
Kurosawa, H [1 ]
机构
[1] Juntendo Univ, Sch Med, Dept Orthopaed, Bunkyo Ku, Tokyo 1138421, Japan
关键词
cobalt and chromium concentrations; metal-on-metal total hip arthroplasty; cementless total hip arthroplasty;
D O I
10.1007/s00402-001-0382-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We measured the cobalt and chromium concentrations in the serum and urine of 32 patients with current designed metal-on-metal total hip arthroplasty and 43 patients with conventional metal on ultrahigh molecular weight polyethylene (UHMWPE) cementless total hip arthroplasty. The results of our study showed that the serum and urine chromium concentrations increased in 37.5% and 90.6%, respectively, of 32 patients with well-fixed metal articulation (the mean values were 0.09 mug/dl and 2.2 mug/l, respectively) and also increased in 28.6% and 85.7%, respectively, of 7 patients who received metalon-UHMWPE articulation with loosened acetabular component or stem made of Co/Cr alloy (the mean values were 0.06 mug/dl and 1.6 mug/l, respectively). On the other hand, the serum and urine cobalt concentrations were below the detection limit in all patients.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 50 条
  • [41] Metal-on-metal articulation in total hip arthroplasty: update
    Srinivasan, Anand
    Levine, Brett R.
    Jacobs, Joshua J.
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (03): : 231 - 235
  • [42] A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty
    Cawley, J
    Metcalf, JEP
    Jones, AH
    Band, TJ
    Skupien, DS
    [J]. WEAR, 2003, 255 : 999 - 1006
  • [43] Serum cobalt concentrations remain at low levels at a minimum of 20 years following metal-on-metal total hip arthroplasty
    Waldstein, W.
    Koller, U.
    Springer, B.
    Kolbitsch, P.
    Brodner, W.
    Windhager, R.
    Lass, R.
    [J]. BONE & JOINT RESEARCH, 2020, 9 (03): : 146 - 151
  • [44] Metal ions levels between metal-on-metal total hip arthroplasty and metal-on-metal hip resurfacing arthroplasty: a meta-analysis
    Zhang, Liang
    Chen, Zhirong
    Li, Lifang
    Li, Peng
    Lu, Zhidong
    Pang, Long
    Song, Kening
    Li, Yaping
    Jin, Qunhua
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 453 - 462
  • [45] Osteolysis in patients with a metal-on-metal hip arthroplasty
    Carr, Ashley M.
    Desteiger, Richard
    [J]. ANZ JOURNAL OF SURGERY, 2008, 78 (03) : 144 - 147
  • [46] Authors' reply to Comment on Management of high concentrations of cobalt and chromium in blood due to metal-on-metal hip arthroplasty in a pregnant woman
    Grulli, Francesca
    Lonati, Davide
    Ronchi, Anna
    Perotti, Francesca
    Spinillo, Arsenio
    Locatelli, Carlo A.
    [J]. CLINICAL TOXICOLOGY, 2021, 59 (01) : 84 - 85
  • [47] Cementless Metasul Metal-On-Metal Total Hip Arthroplasties at 13 Years
    Randelli, Filippo
    Banci, Lorenzo
    D'Anna, Alessandro
    Visentin, Ornella
    Randelli, Gianni
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (02): : 186 - 192
  • [48] Is a cementless fixation of the femoral component suitable for metal-on-metal hip resurfacing arthroplasty?
    Amstutz, Harlan C.
    Le Duff, Michel J.
    [J]. HIP INTERNATIONAL, 2019, 29 (06) : 624 - 629
  • [49] Serum metal (titanium, chromium and cobalt) concentrations in the follow-up of total hip arthroplasty
    Seijas Martinez-Echevarria, V
    Janez Carrera, R.
    Lopez Colon, J. L.
    Sanz Gomez, T. A.
    Vergara, A.
    Cornet Flores, B. A.
    Hernando de larramendi Martinez, C.
    [J]. TRAUMA-SPAIN, 2012, 23 (04): : 223 - 227
  • [50] The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty
    Cobb, AG
    Schmalzreid, TP
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 385 - 398