Measurement of the expiratory ammonia concentration and its clinical significance

被引:18
|
作者
Wakabayashi, H
Kuwabara, Y
Murata, H
Kobashi, K
Watanabe, A
机构
[1] TOYAMA MED & PHARMACEUT UNIV,FAC MED,DEPT INTERNAL MED 3,TOYAMA 93001,JAPAN
[2] TOYAMA MED & PHARMACEUT UNIV,FAC MED,DEPT BIOL CHEM,TOYAMA 93001,JAPAN
关键词
ammonia; NH4+; gaseous ammonia; expiratory air; hepatic encephalopathy; liver cirrhosis;
D O I
10.1023/B:MEBR.0000007110.79274.37
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although gaseous ammonia (NH3) can freely enter cells through the plasma membrane where NH3 is cyto(neuro)toxic, NH3 and ionic ammonia (NH4+) contents have not been studied in biological materials. We developed a new method for measurement of expiratory NH3 concentration, which may reflect blood NH3 concentrations. The method is a sensor tube type-gas assay system. Expiratory NH3 concentration in patients with chronic liver diseases increased when their blood ammonia (NH4+ + NH3) concentrations increased above 90 mu g/dl (normal range; 12-66 mu g/dl). However, cirrhotic patients, who had relatively higher expiratory NH3 concentration compared to blood NH, concentrations (calculated from Henderson-Hasselbalch formula), were found to have subclinical encephalopathy. Measurement of expiratory NH3 concentration may be of clinical significance for the diagnosis of encephalopathy associated with hyperammonemia.
引用
收藏
页码:161 / 169
页数:9
相关论文
共 50 条
  • [21] Radiologic measurement of lesser trochanter and its clinical significance in Chinese
    Zhang, Qi
    Liu, Huaijun
    Chen, Wei
    Li, Xicheng
    Song, Zhaohui
    Pan, Jinshe
    Zhang, Yingze
    SKELETAL RADIOLOGY, 2009, 38 (12) : 1175 - 1181
  • [22] MEASUREMENT OF LUMBAR SPINAL CANAL BY ULTRASOUND AND ITS CLINICAL SIGNIFICANCE
    PORTER, RW
    WICKS, MA
    OTTEWELL, D
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (03): : 438 - 439
  • [23] Serum lipoprotein lipase mass: Clinical significance of its measurement
    Kobayashi, Junji
    Nohara, Atsushi
    Kawashiri, Masa-aki
    Inazu, Akihiro
    Koizumi, Junji
    Nakajima, Katsuyuki
    Mabuchi, Hiroshi
    CLINICA CHIMICA ACTA, 2007, 378 (1-2) : 7 - 12
  • [25] Radiologic measurement of lesser trochanter and its clinical significance in Chinese
    Qi Zhang
    Huaijun Liu
    Wei Chen
    Xicheng Li
    Zhaohui Song
    Jinshe Pan
    Yingze Zhang
    Skeletal Radiology, 2009, 38 : 1175 - 1181
  • [26] Airway Hyperresponsiveness in Asthma: Its Measurement and Clinical Significance Introduction
    O'Byrne, Paul M.
    CHEST, 2010, 138 (02) : 1S - 3S
  • [27] A FOOT PRESSURE MEASUREMENT SYSTEM AND ITS CLINICAL-SIGNIFICANCE
    CHENG, YM
    JIANG, YM
    GU, XJ
    JIANG, ZJ
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1291 - 1291
  • [28] Clinical significance of measurement of plasma annexin V concentration of patients in the emergency room
    Matsuda, R
    Kaneko, N
    Kikuchi, M
    Chiwaki, F
    Toda, M
    Ieiri, T
    Horikawa, Y
    Shimizu, M
    Shimamoto, K
    RESUSCITATION, 2003, 57 (02) : 171 - 177
  • [29] AMMONIA CONCENTRATION MEASUREMENT BY CATALYTIC-OXIDATION
    TAKAHASHI, S
    YAMASHITA, I
    JSME INTERNATIONAL JOURNAL SERIES II-FLUIDS ENGINEERING HEAT TRANSFER POWER COMBUSTION THERMOPHYSICAL PROPERTIES, 1989, 32 (03): : 449 - 454
  • [30] Ammonia concentration measurement using oxidizing catalyst
    Takahashi, Sanyo
    Yamashita, Iwao
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1988, 54 (506): : 2979 - 2983