Influence of the Measurement Parameters on Depth-Resolved Residual Stress Measurements of Deep Rolled Construction Steel using Energy Dispersive X-ray Diffraction

被引:2
|
作者
Breidenstein, B. [1 ]
Heikebruegge, S. [1 ]
Schaumann, P. [2 ]
Daenekas, C. [2 ]
机构
[1] Leibniz Univ Hannover, Inst Fertigungstech & Werkzeugmaschinen, Univ 2, D-30823 Hannover, Germany
[2] Leibniz Univ Hannover, Inst Stahlbau, Appelstr 9a, D-30167 Hannover, Germany
来源
关键词
Residual stresses; energy dispersive; angle dispersive; X-ray diffraction; deep rolling; tailored surfaces; construction steel; STATES;
D O I
10.3139/105.110423
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the influence of different measurement parameters of energy dispersive residual stress measurements on the obtained residual stress depth profiles of deep rolled construction steel S355 G10+M was investigated. Especially the diffraction angle. and afterwards the measuring time t per inclination angle. were varied. A diffraction angle of theta = 20 degrees shows an acceptable compromise between achievable information depth and detected total intensity of diffracted X-ray quanta. Furthermore, a measuring time per inclination angle. of t = 2,400 s leads to an acceptable standard deviation regarding the determined residual stress states. With these parameters for the energy-dispersive measurement, a comparison between angle-dispersive and energy-dispersive determination of residual stress depth profiles was carried out. Quantitative similarities between these two methods were observed, whereby the energy-dispersive determined residual stress depth profiles are rather discontinuous. A possible explanation could be found in the model used for the calculation of the net-plane-dependent radiographic elastic constants (XEC). In general, the energy-dispersive residual stress measurement was qualified for the determination of residual stress depth profiles of deep rolled construction steel. Based on the findings, a time-efficient non-destructive residual stress measurement can be carried out in the future with the discussed measurement parameters at maximum possible information depth.
引用
收藏
页码:419 / 432
页数:14
相关论文
共 50 条
  • [21] On the Surface Residual Stress Measurement in Magnesium Alloys Using X-Ray Diffraction
    Yazdanmehr, Amir
    Jahed, Hamid
    MATERIALS, 2020, 13 (22) : 1 - 18
  • [22] Comparison of Residual Stress Measurement Techniques and Implementation Using X-Ray Diffraction
    Belassel, M.
    Pineault, J.
    Caratanasov, N.
    Brauss, M.
    RESIDUAL STRESSES 2016: ICRS-10, 2017, 2 : 43 - 48
  • [23] Automatic inverse pole figure measurement in steel by energy-dispersive X-ray diffraction
    Katayama, Michio
    Shimizu, Masato
    Maeda, Chizuko
    Kawasaki Steel Technical Report, 1988, (19): : 94 - 99
  • [24] Residual stress measurement with focused acoustic waves and direct comparison with X-ray diffraction stress measurements
    Sathish, S
    Moran, TJ
    Martin, RW
    Reibel, R
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2005, 399 (1-2): : 84 - 91
  • [25] Fast residual stress mapping using energy-dispersive synchrotron X-ray diffraction on station 16.3 at the SRS
    Korsunsky, AM
    Collins, SP
    Owen, RA
    Daymond, MR
    Achtioui, S
    James, KE
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 77 - 81
  • [26] Measurement of residual stress induced by laser irradiation on grain oriented silicon steel using X-ray diffraction
    Musashi Inst of Tech., Setagaya-ku, Tokyo, 158-8557
    不详
    不详
    不详
    不详
    Zairyo, 2007, 7 (609-614):
  • [27] Control of geometrical sources of error in residual stress analysis by energy-dispersive X-ray diffraction
    Alfonso, JA
    Greaves, ED
    Lavelle, B
    Sajo-Bohus, L
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2003, 38 (04): : 283 - 288
  • [28] Depth-selective x-ray diffraction using energy-dispersive x-ray detector and straight capillary optics
    Fukumoto, Shotaro
    Okuda, Masaki
    Matsuyama, Tsugufumi
    Tsuji, Kouichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (06):
  • [29] A comparison of residual stress measurements in steels using the X-ray and the neutron diffraction techniques
    Celard, NJ
    Pathiraj, B
    Nikbin, K
    Webster, GA
    ECRS 5: PROCEEDINGS OF THE FIFTH EUROPEAN CONFERENCE ON RESIDUAL STRESSES, 2000, 347-3 : 316 - 321
  • [30] Comparison of residual stress measurements in steels using the X-ray and the neutron diffraction techniques
    Department of Mechanical Engineering, Imperial College, London, SW7 2BX, United Kingdom
    不详
    Materials Science Forum, 2000, 347 : 316 - 321