Scalable and Accurate ECG Simulation for Reaction-Diffusion Models of the Human Heart

被引:41
|
作者
Potse, Mark [1 ,2 ,3 ]
机构
[1] Inria Bordeaux Sud Ouest, CARMEN Res Team, Talence, France
[2] Univ Bordeaux, Inst Math Bordeaux, UMR 5251, Talence, France
[3] Fdn Bordeaux Univ, Electrophysiol & Heart Modeling Inst, IHU Liryc, Pessac, France
来源
FRONTIERS IN PHYSIOLOGY | 2018年 / 9卷
关键词
numerical modeling; electrocardiogram; high-performance computing; reaction-diffusion model; bidomain model; lead fields; OPTIMAL MONODOMAIN APPROXIMATIONS; VENTRICULAR ACTION-POTENTIALS; CARDIAC ELECTROPHYSIOLOGY; BIDOMAIN EQUATIONS; FINITE-ELEMENT; SURFACE-POTENTIALS; T-WAVE; COMPUTER; ELECTROGRAMS; PROPAGATION;
D O I
10.3389/fphys.2018.00370
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Realistic electrocardiogram (ECG) simulation with numerical models is important for research linking cellular and molecular physiology to clinically observable signals, and crucial for patient tailoring of numerical heart models. However, ECG simulation with a realistic torso model is computationally much harder than simulation of cardiac activity itself, so that many studies with sophisticated heart models have resorted to crude approximations of the ECG. This paper shows how the classical concept of electrocardiographic lead fields can be used for an ECG simulation method that matches the realism of modern heart models. The accuracy and resource requirements were compared to those of a full-torso solution for the potential and scaling was tested up to 14,336 cores with a heart model consisting of 11 million nodes. Reference ECGs were computed on a 3.3 billion-node heart-torso mesh at 0.2 mm resolution. The results show that the lead-field method is more efficient than a full-torso solution when the number of simulated samples is larger than the number of computed ECG leads. While the initial computation of the lead fields remains a hard and poorly scalable problem, the ECG computation itself scales almost perfectly and, even for several hundreds of ECG leads, takes much less time than the underlying simulation of cardiac activity.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Validation and calibration of models for reaction-diffusion systems
    Dilao, R
    Sainhas, J
    INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 1998, 8 (06): : 1163 - 1182
  • [32] Mathematical properties of models of the reaction-diffusion type
    Beccaria, M
    Soliani, G
    PHYSICA A, 1998, 260 (3-4): : 301 - 337
  • [33] Phase transition of triplet reaction-diffusion models
    Odor, G
    PHYSICAL REVIEW E, 2006, 73 (04):
  • [34] Propagation and reaction-diffusion models with free boundaries
    Du, Yihong
    BULLETIN OF MATHEMATICAL SCIENCES, 2022, 12 (01)
  • [35] Learning Reaction-Diffusion Models for Image Inpainting
    Yu, Wei
    Heber, Stefan
    Pock, Thomas
    PATTERN RECOGNITION, GCPR 2015, 2015, 9358 : 356 - 367
  • [36] Invariants of reaction-diffusion cellular automata models
    Bandman, O. L.
    PRIKLADNAYA DISKRETNAYA MATEMATIKA, 2012, 17 (03): : 108 - 120
  • [37] Mathematical properties of models of the reaction-diffusion type
    Beccaria, M.
    Soliani, G.
    Physica A: Statistical Mechanics and its Applications, 1998, 260 (3-4): : 301 - 337
  • [38] Reaction-diffusion models for morphological patterning of hESCs
    Bedekar, Prajakta
    Timofeyev, Ilya
    Warmflash, Aryeh
    Perepelitsa, Misha
    JOURNAL OF MATHEMATICAL BIOLOGY, 2021, 83 (05)
  • [39] ANALYSIS OF PROPAGATION FOR IMPULSIVE REACTION-DIFFUSION MODELS
    Fazly, Mostafa
    Lewis, Mark
    Wang, Hao
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2020, 80 (01) : 521 - 542
  • [40] Reaction-diffusion models with large advection coefficients
    Bezuglyy, Andriy
    Lou, Yuan
    APPLICABLE ANALYSIS, 2010, 89 (07) : 983 - 1004