CT-subtraction angiography (CTSA). Results with an automated ''elastic'' subtraction algorithm

被引:0
|
作者
Luboldt, W [1 ]
Stehling, MK [1 ]
Pearlman, JD [1 ]
Seemann, R [1 ]
Raptopoulos, V [1 ]
机构
[1] HARVARD UNIV,BETH ISRAEL HOSP,SCH MED,DEPT RADIOL,BOSTON,MA
来源
RADIOLOGE | 1997年 / 37卷 / 01期
关键词
spiral computed tomography; CT-angiography (CTA); CT-subtraction-angiography (CTSA);
D O I
10.1007/s001170050181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and implement a method to obtain digital subtraction (DS) spiral computed tomography angiograms (SCTA) in order to avoid superimposition of bony structures and vascular calcifications on SCTA maximum intensity projections (MIPs) and shaded surface display (SSD). Method: Two SCTA data sets, one before and one during the injection of a contrast agent bolus, were obtained with identical scan parameters. Since ordinary subtraction of the two data sets fairs to reliably separate bones and calcifications from the vascular lumen because of motion, a so-called elastic subtraction procedure was designed to correct 3D misregistration between the two data sets. It automatically accommodates for local position changes between baseline and contrast images, including regionally inconsistent non-linear displacements and arbitrary rotations. This method was tested in seven patients and evaluated against ordinary DS in terms of image quality and artifacts. Results: In all patients ''elastic'' CTSA proved superior to ordinary DS. It provides automated and reliable separation of vessels from bones and calcifications. This improves the delineation of vessels in the neck and the skull base and of intracranial vessels. DS-SCTA facilitates MIPs and SSD without artifacts introduced by thresholding. Conclusion: Elastic DS-SCTA is a robust method for automated un-masking of vessels from bones and warrants clinical trials and comparison with MR- and conventional angiography.
引用
收藏
页码:89 / 93
页数:5
相关论文
共 50 条
  • [1] CT-subtraction angiography (CTSA): Results with an automated 'elastic' subtraction algorithm [CT-Subtraktionsangiographie (CTSA). Ergebnisse mit einem automatisierten 'elastischen' Subtraktionsalgorithmus]
    Luboldt W.
    Stehling M.K.
    Pearlman J.D.
    Seemann M.
    Raptopoulos V.
    [J]. Der Radiologe, 1997, 37 (1): : 89 - 93
  • [2] An improved subtraction algorithm in Digital Subtraction Angiography (DSA)
    Jiang, LH
    Chai, ZM
    Sun, HS
    [J]. CHINESE JOURNAL OF ELECTRONICS, 2000, 9 (02) : 185 - 188
  • [3] 3-DIMENSIONAL ELASTIC SUBTRACTION SPIRAL CT ANGIOGRAPHY
    PEARLMAN, JD
    RAPTOPOULOS, VD
    KLEEFIELD, J
    [J]. RADIOLOGY, 1995, 197 : 143 - 144
  • [4] Novel Automated 3D Registration in CT Subtraction Angiography
    Peter, R.
    Malinsky, M.
    Jan, J.
    Ourednicek, P.
    [J]. ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 133 - 137
  • [5] CT SCAN AND SUBTRACTION ANGIOGRAPHY IN CHEMODECTOMAS
    OCALLAGHAN, J
    TIMPERLEY, WR
    WARD, P
    [J]. CLINICAL RADIOLOGY, 1979, 30 (05) : 575 - 580
  • [6] A Fast Subtraction Algorithm of Brain CT Angiography Images based on MMBE
    Han, Fangfang
    Yang, Jinzhu
    Zhao, Dazhe
    Zhao, Hong
    [J]. PROCEEDING OF THE IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION, 2012, : 226 - 229
  • [7] AUTOMATED IMAGE REGISTRATION FOR DIGITAL SUBTRACTION ANGIOGRAPHY
    POTEL, MJ
    GUSTAFSON, DE
    [J]. MEDICAL PHYSICS, 1983, 10 (01) : 129 - 129
  • [8] Automated Subtraction CT Angiography for Visualization of the Whole Brain Vasculature: A Feasibility Study
    Li, Qi
    Lv, Fajin
    Wei, Youdong
    Luo, Tianyou
    Xie, Peng
    [J]. ACADEMIC RADIOLOGY, 2013, 20 (08) : 1009 - 1014
  • [9] Image Noise Reduction Algorithm for Digital Subtraction Angiography: Clinical Results
    Soderman, Michael
    Holmin, Staffan
    Andersson, Tommy
    Palmgren, Charlotta
    Babic, Drazenko
    Hoornaert, Bart
    [J]. RADIOLOGY, 2013, 269 (02) : 553 - 560
  • [10] Automated algorithm for baseline subtraction in spectra
    Rowlands, Christopher
    Elliott, Stephen
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 2011, 42 (03) : 363 - 369