Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?

被引:7
|
作者
Ahmed, Asmaa Ismail [1 ]
Baz, Heba [1 ]
Lotfy, Sarah [1 ]
机构
[1] Cairo Univ, Fac Med, Clin & Chem Pathol Dept, Kasr Al Aini St, Cairo, Egypt
关键词
urine; automation; H800-FUS100; evaluation; URINE SEDIMENT EXAMINATION; MICROSCOPY; ANALYZERS;
D O I
10.7754/Clin.Lab.2015.150520
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUS100 automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. Methods: 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carry-over, drift, sensitivity, specificity, and practicability criteria were tested. Results: Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was >= 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). Conclusions: Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [41] Manual versus automated qualitative usability assessment of interactive systems
    Sagar, Kalpna
    Gupta, Deepak
    Sangaiah, Arun K.
    CONCURRENCY AND COMPUTATION-PRACTICE & EXPERIENCE, 2021, 33 (12):
  • [42] Coagulation and fibrinolytic responses to manual versus automated snow removal
    Womack, CJ
    Paton, CM
    Coughlin, AM
    Nagelkirk, PR
    Dejong, AT
    Anderson, J
    Franklin, BA
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (10): : 1755 - 1759
  • [43] Automated versus manual sample inoculations in routine clinical microbiology
    Sakurada, Andrea
    REVISTA CHILENA DE INFECTOLOGIA, 2014, 31 (02): : 225 - 225
  • [44] Automated Versus Manual In Vivo Segmentation of Carotid Plaque MRI
    van 't Klooster, R.
    Naggara, O.
    Marsico, R.
    Reiber, J. H. C.
    Meder, J. -F.
    van der Geest, R. J.
    Touze, E.
    Oppenheim, C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1621 - 1627
  • [45] Blood components fractionation: Manual versus automated procedure.
    Pasqualetti, D
    Vaglio, S
    Arista, MC
    Alimenti, G
    Salvagnini, ML
    Girelli, G
    TRANSFUSION, 2002, 42 (09) : 54S - 54S
  • [46] Statistical analysis of automated versus manual pavement condition surveys
    McQueen, JM
    Timm, DH
    PAVEMENT MANAGEMENT; MONITORING, EVALUATION, AND DATA STORAGE; AND ACCELERATED TESTING 2005, 2005, (1940): : 55 - 62
  • [47] Comparative study of automated versus manual measurement of body temperature
    Pandarbale, Sanjay
    Sardessai, Sandip
    Rodrigues, Edelweiss
    JOURNAL OF THE SCIENTIFIC SOCIETY, 2021, 48 (03) : 161 - 164
  • [48] Are Automated Blood Pressure Apparatus Reliable? Automated Versus Manual Measurement of Blood Pressure
    Srinivasan, K. Madhan
    Kumar, K. Senthil
    Saraswathi, I.
    Raaju, A. Lokeshwar
    Rao, B. Vishwanatha
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (08) : CC9 - CC12
  • [49] AUTOMATED AND MANUAL ILL - TIME EFFECTIVENESS AND SUCCESS RATE
    TALER, I
    KLAPPER, P
    INFORMATION TECHNOLOGY AND LIBRARIES, 1982, 1 (03) : 277 - 280
  • [50] Comparison of the time required for manual (visually read) and semi-automated POCT urinalysis and pregnancy testing with associated electronic medical record (EMR) transcription errors
    Young, Paul E.
    Diaz, Gabriel J.
    Kalariya, Rinaben N.
    Mann, Peggy A.
    Benbrook, Maegan N.
    Avandsalehi, Kurosh R.
    Petersen, John R.
    CLINICA CHIMICA ACTA, 2020, 504 : 60 - 63