Influence of surface light scattering and glistenings of intraocular lenses on visual function 15 to 20 years after surgery

被引:11
|
作者
Oshika, Tetsuro [1 ]
Ando, Hiroshi [2 ]
Inoue, Yasushi [3 ]
Eguchi, Shuichiro [4 ]
Sato, Yukio [5 ]
Sugita, Toru [6 ]
Nishimura, Tomohisa [8 ]
Hayashi, Ken [9 ]
Fujita, Yoshifumi [10 ]
Miyata, Akira [11 ]
Sasaki, Noriyuki [7 ]
Miyata, Kazunori [12 ]
机构
[1] Univ Tsukuba, Fac Med, Dept Ophthalmol, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058575, Japan
[2] Ando Eye Clin, Kanagawa, Japan
[3] Inoue Eye Clin, Okayama, Japan
[4] Eguchi Eye Hosp, Hakodate, Hokkaido, Japan
[5] Yurinoki Clin, Nagano, Japan
[6] Sugita Eye Clin, Tokyo, Japan
[7] Alcon Japan Ltd, Tokyo, Japan
[8] Mikawa Eye Clin, Saga, Japan
[9] Hayashi Eye Hosp, Fukuoka, Japan
[10] Fujita Eye Clin, Tokushima, Japan
[11] Miyata Eye Clin, Hiroshima, Japan
[12] Miyata Eye Hosp, Miyazaki, Japan
来源
关键词
POSTERIOR CAPSULE OPACIFICATION; SUBSURFACE NANOGLISTENINGS; CONTRAST SENSITIVITY; CLINICAL-EVALUATION; TRANSMITTANCE; QUALITY; ACUITY;
D O I
10.1016/j.jcrs.2017.12.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the long-term influence of surface light scattering and glistenings of hydrophobic acrylic (Acrysof), silicone, and poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) on visual function. Setting: Eleven surgical sites, Japan. Design: Retrospective case series. Methods: Patients who had cataract surgery with implantation of a hydrophobic acrylic, silicone, or PMMA IOL from 1994 to 2000 were examined. Silicone and PMMA IOLs were not restricted to specific manufacturers or models. Patients were included if their corrected distance visual acuity (CDVA) within 3 months postoperatively (baseline CDVA) was 20/25 or better. The CDVA, contrast sensitivity, degree of surface light scattering measured with Pentacam densitometry, and glistening grades were recorded at the patient's latest visit. Results: Of the eyes, 31 had a hydrophobic acrylic IOL, 37 a silicone IOL, and 30 a PMMA IOL. Surface light scattering and glistenings were significantly greater with the hydrophobic acrylic IOL than with silicone and PMMA IOLs (P < .0001). The CDVA at the latest visit as well as the changes in CDVA from the baseline to the latest visit did not differ between the IOLs and was unaffected by surface light scattering and glistenings, as was the contrast sensitivity. Conclusions: The hydrophobic acrylic IOL was associated with a significantly greater level of surface light scattering and glistenings than the silicone IOLs and PMMA IOLs 15 to 20 years postoperatively. However, the optical phenomena within the optics of the hydrophobic acrylic IOL did not influence the patients' visual function. (c) 2018 ASCRS and ESCRS
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [11] Effect on visual acuity of increased surface light scattering in intraocular lenses
    Miyata, Kazunori
    Honbo, Masato
    Otani, Shinichiro
    Nejima, Ryohei
    Minami, Keiichiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 221 - 226
  • [12] Glistenings 9 years after phacoemulsification in hydrophobic and hydrophilic acrylic intraocular lenses
    Chang, Anthony
    Kugelberg, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1199 - 1204
  • [13] Influence of surface light scattering in hydrophobic acrylic intraocular lenses on laser beam transmittance
    Shiraya, Tomoyasu
    Kato, Satoshi
    Minami, Keiichiro
    Miyata, Kazunori
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) : 251 - 255
  • [14] Influence of surface light scattering in hydrophobic acrylic intraocular lenses on laser beam transmittance
    Tomoyasu Shiraya
    Satoshi Kato
    Keiichiro Minami
    Kazunori Miyata
    International Ophthalmology, 2017, 37 : 251 - 255
  • [15] Comparison of postoperative surface light scattering of different intraocular lenses
    Miyata, K.
    Otani, S.
    Nejima, R.
    Miyai, T.
    Samejima, T.
    Honbo, M.
    Minami, K.
    Amano, S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 684 - 687
  • [16] Etiology of surface light scattering on hydrophobic acrylic intraocular lenses
    Ong, Marcia D.
    Callaghan, Thomas A.
    Pei, Ron
    Karakelle, Mutlu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1833 - 1844
  • [17] Improvements in visual function early after cataract surgery in eyes implanted with multifocal intraocular lenses
    Hayashi, Ken
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Hirata, Akira
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2025, 69 (01) : 32 - 42
  • [18] Light Transmittance of Explanted Hydrophobic Acrylic Intraocular Lenses with Surface Light Scattering
    Werner, Liliana
    Morris, Caleb
    Stallings, Shannon
    Liu, Erica
    Floyd, Anne
    Ollerton, Andrew
    Leishman, Lisa
    Bodnar, Zachary
    Ong, Marcia
    Akinay, Ali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [19] In vitro examination of surface light scattering in hydrophobic acrylic intraocular lenses
    Minami, Keiichiro
    Maruyama, Yoko
    Honbo, Masato
    Matsunaga, Jiro
    Miyata, Kazunori
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 652 - 656
  • [20] Optical performance of hydrophobic acrylic intraocular lenses with surface light scattering
    Ogura, Yuichiro
    Ong, Marcia D.
    Akinay, Ali
    Carson, Daniel R.
    Pei, Ron
    Karakelle, Mutlu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01): : 104 - 113