Influence of surface light scattering and glistenings of intraocular lenses on visual function 15 to 20 years after surgery

被引:11
|
作者
Oshika, Tetsuro [1 ]
Ando, Hiroshi [2 ]
Inoue, Yasushi [3 ]
Eguchi, Shuichiro [4 ]
Sato, Yukio [5 ]
Sugita, Toru [6 ]
Nishimura, Tomohisa [8 ]
Hayashi, Ken [9 ]
Fujita, Yoshifumi [10 ]
Miyata, Akira [11 ]
Sasaki, Noriyuki [7 ]
Miyata, Kazunori [12 ]
机构
[1] Univ Tsukuba, Fac Med, Dept Ophthalmol, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058575, Japan
[2] Ando Eye Clin, Kanagawa, Japan
[3] Inoue Eye Clin, Okayama, Japan
[4] Eguchi Eye Hosp, Hakodate, Hokkaido, Japan
[5] Yurinoki Clin, Nagano, Japan
[6] Sugita Eye Clin, Tokyo, Japan
[7] Alcon Japan Ltd, Tokyo, Japan
[8] Mikawa Eye Clin, Saga, Japan
[9] Hayashi Eye Hosp, Fukuoka, Japan
[10] Fujita Eye Clin, Tokushima, Japan
[11] Miyata Eye Clin, Hiroshima, Japan
[12] Miyata Eye Hosp, Miyazaki, Japan
来源
关键词
POSTERIOR CAPSULE OPACIFICATION; SUBSURFACE NANOGLISTENINGS; CONTRAST SENSITIVITY; CLINICAL-EVALUATION; TRANSMITTANCE; QUALITY; ACUITY;
D O I
10.1016/j.jcrs.2017.12.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the long-term influence of surface light scattering and glistenings of hydrophobic acrylic (Acrysof), silicone, and poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) on visual function. Setting: Eleven surgical sites, Japan. Design: Retrospective case series. Methods: Patients who had cataract surgery with implantation of a hydrophobic acrylic, silicone, or PMMA IOL from 1994 to 2000 were examined. Silicone and PMMA IOLs were not restricted to specific manufacturers or models. Patients were included if their corrected distance visual acuity (CDVA) within 3 months postoperatively (baseline CDVA) was 20/25 or better. The CDVA, contrast sensitivity, degree of surface light scattering measured with Pentacam densitometry, and glistening grades were recorded at the patient's latest visit. Results: Of the eyes, 31 had a hydrophobic acrylic IOL, 37 a silicone IOL, and 30 a PMMA IOL. Surface light scattering and glistenings were significantly greater with the hydrophobic acrylic IOL than with silicone and PMMA IOLs (P < .0001). The CDVA at the latest visit as well as the changes in CDVA from the baseline to the latest visit did not differ between the IOLs and was unaffected by surface light scattering and glistenings, as was the contrast sensitivity. Conclusions: The hydrophobic acrylic IOL was associated with a significantly greater level of surface light scattering and glistenings than the silicone IOLs and PMMA IOLs 15 to 20 years postoperatively. However, the optical phenomena within the optics of the hydrophobic acrylic IOL did not influence the patients' visual function. (c) 2018 ASCRS and ESCRS
引用
收藏
页码:219 / 225
页数:7
相关论文
共 50 条
  • [1] Glistenings and surface light scattering in intraocular lenses
    Werner, Liliana
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08): : 1398 - 1420
  • [2] Long-Term Effect of Surface Light Scattering and Glistenings of Intraocular Lenses on Visual Function
    Hayashi, Ken
    Hirata, Akira
    Yoshida, Motoaki
    Yoshimura, Koichi
    Hayashi, Hideyuki
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (02) : 240 - 251
  • [3] Change in light scattering caused by glistenings in hydrophobic acrylic intraocular lenses from 10 to 15 years after surgery
    Monestam, Eva
    Behndig, Anders
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (06): : 864 - 869
  • [4] Light scattering in intraocular lenses explanted 15 to 40 years after surgery
    Alio, Jorge L.
    Arias, Augusto
    D'Oria, Francesco
    Toto, Francesca
    Del Barrio, Jorge Alio
    Duarte, Raul
    Artal, Pablo
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (06) : 3485 - 3494
  • [5] Impact on visual function from light scattering and glistenings in intraocular lenses, a long-term study
    Moenestam, Eva
    Behndig, Anders
    ACTA OPHTHALMOLOGICA, 2011, 89 (08) : 724 - 728
  • [6] Surface light scattering and visual function of diffractive multifocal hydrophobic acrylic intraocular lenses 6 years after implantation
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    Yoshino, Mami
    Taira, Yoko
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (11): : 1729 - 1733
  • [7] Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses
    Gunenc, U
    Oner, FH
    Tongal, S
    Ferliel, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10): : 1611 - 1614
  • [8] Glistenings in hydrophobic acrylic intraocular lenses do affect visual function
    Beiko, George H. H.
    Grzybowski, Andrzej
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 2271 - +
  • [9] Influence on visual function of forward light scattering associated with subsurface nanoglistenings in intraocular lenses
    Beheregaray, Simone
    Yamamoto, Toshiya
    Hiraoka, Takahiro
    Oshika, Tetsuro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07): : 1147 - 1154
  • [10] Glistenings in hydrophobic acrylic intraocular lenses do affect visual function reply
    Thomes, Brett E.
    Callaghan, Thomas A.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 2273 - 2274