Ultrasound-guided percutaneous release of the annular pulley in trigger digit

被引:50
|
作者
Rajeswaran, Gajan [1 ]
Lee, Justin C. [1 ]
Eckersley, Rupert [2 ]
Katsarma, Effie [2 ]
Healy, Jeremiah C. [1 ]
机构
[1] Chelsea & Westminster Hosp, Dept Radiol, London SW10 9NH, England
[2] Chelsea & Westminster Hosp, Dept Hand Surg, London SW10 9NH, England
关键词
Trigger digit; Trigger finger; Ultrasound guided; Percutaneous release; Annular pulley; A1; pulley; FINGER RELEASE; A1; PULLEY; SURGICAL-TREATMENT; THUMB; KNIFE; NEEDLE; NERVE;
D O I
10.1007/s00330-009-1397-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to describe and evaluate a new technique for ultrasound-guided percutaneous release of the annular pulley in trigger digit using a modified hypodermic needle. A total of 35 ultrasound-guided percutaneous releases were performed on 25 patients diagnosed and referred by hand surgeons in our institution over 16 months from October 2006. Inclusion criteria were as follows: adulthood, triggering present for at least 4 months, failure to respond to conservative management or steroid injections, no previous history of pulley release in the affected digit. Under ultrasound guidance, the affected pulley was released using a standard 19-gauge hypodermic needle bent at two points as the cutting device. Follow-up took place at 12 weeks and 6 months with improvement in triggering and clinically graded pain. At follow-up, no complications had occurred and all patients demonstrated improvement in their triggering, with complete resolution in 32 digits (91%), good improvement in 2 digits (6%) and some improvement in 1 digit (3%). This new technique uses a widely available and safe cutting device and is safe and can be used to provide definitive management for trigger finger, allowing the procedure to be performed in a variety of clinical settings.
引用
收藏
页码:2232 / 2237
页数:6
相关论文
共 50 条
  • [31] ULTRASOUND-GUIDED PERCUTANEOUS URETEROSTOMY
    MANGIN, P
    NAVARRO, JM
    CHARLES, JF
    ANNALES D UROLOGIE, 1987, 21 (03) : 199 - 204
  • [32] PERCUTANEOUS ULTRASOUND-GUIDED ESOPHAGOSTOMY
    JONES, GRM
    NICHOLSON, DM
    JOURNAL OF ULTRASOUND IN MEDICINE, 1988, 7 (11) : 643 - 645
  • [33] Ultrasound-Guided Percutaneous Tenotomy
    Jacobson, Jon A.
    Kim, Sung Moon
    Brigido, Monica Kalume
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2016, 20 (05) : 414 - 421
  • [34] Sonographically Guided Percutaneous First Annular Pulley Release Cadaveric Safety Study of Needle and Knife Techniques
    Smith, Jay
    Rizzo, Marco
    Lai, Jim K.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (11) : 1531 - 1542
  • [35] Percutaneous release of trigger digit with and without cortisone injection
    Patel, MR
    Moradia, VJ
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (01): : 150 - 155
  • [36] Comparative study of ultrasonography-guided percutaneous AI pulley release versus blinded percutaneous AI pulley release
    Lee, Sung Hyun
    Choi, Young Chae
    Kang, Hong Je
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02):
  • [37] Efficacy of Ultrasound-Guided Tendon Release for Trigger Finger Compared With Open Surgery
    Amro, Sarah
    Kashbour, Muataz
    Shaaban Abdelgalil, Mahmoud
    Qafesha, Ruaa Mustafa
    Eldeeb, Hatem
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (04) : 657 - 669
  • [38] Percutaneous ultrasound guided A1 pulley release. Part II: Intravaginal technique
    Rojo Manaute, J. M.
    Igualada Blazquez, C.
    Lopez Soto, V
    de las Heras Sanchez-Heredero, J.
    Del Cerro Gutierrez, M.
    Vaquero Martin, J.
    TRAUMA-SPAIN, 2010, 21 (03): : 141 - 149
  • [39] Sonographically Guided Intrasheath Percutaneous Release of the First Annular Pulley for Trigger Digits, Part 2 Rancomized Comparative Study of the Economic Impact of 3 Surgical Models
    Manuel Rojo-Manaute, Jose
    Capa-Grasa, Alberto
    Del Cerro-Gutierrez, Miguel
    Villanueva Martinez, Manuel
    Chana-Rodriguez, Francisco
    Vaquero Martin, Javier
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (03) : 427 - 438
  • [40] Morphological alterations of the tendon and pulley on ultrasound after intrasynovial injection of betamethasone for trigger digit
    Takahashi, Mitsuhiko
    Sato, Ryosuke
    Kondo, Kenji
    Sairyo, Koichi
    ULTRASONOGRAPHY, 2018, 37 (02) : 134 - 139