Power Quality Analysis by H-Bridge DSTATCOM Control by Icosθ and ESRF SOGI-FLL Methods for Different Industrial Loads

被引:0
|
作者
Islavatu, Srikanth [1 ]
Kumar, Pradeep [1 ]
Kumar, Amit [1 ]
Salkuti, Surender Reddy [2 ]
机构
[1] Natl Inst Technol Sikkim, Dept Elect & Elect Engn, Sikkim 737139, India
[2] Woosong Univ, Dept Railrd & Elect Engn, Jayang Dong, Daejeon 34606, South Korea
来源
SMART CITIES | 2022年 / 5卷 / 04期
关键词
Icos theta; enhanced SRF SOGI-FLL; harmonic; voltage source- and current source-based non-linear loads; induction heating-based loads; electric arc furnace; MITIGATION;
D O I
10.3390/smartcities5040081
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work develops the analysis of power quality by the H-bridge Static Distribution Compensator (DSTATCOM) as well as its control techniques in different industry-based loading conditions. The function of DSTATCOM is to diminish power quality problems arising due to commercial as well as industrial loads. For reference current extraction, the novel Icos theta and proposed enhanced SRF SOGI-FLL (synchronous reference frame second-order generalized integrator frequency-locked loop) controller have been adopted in the H-bridge DSTATCOM. The Icos theta controller's performance is dependent on the in-phase and quadrature-phase angle, which changes accordingly as load changes, whereas the proposed enhanced SRF SOGI-FLL controller works in synchronization with the grid with an inverter. The two control techniques were compared in terms of balancing, power factor improvement, DC-link voltage control, and harmonic minimization. The harmonics minimization of the proposed controller has been validated by IEEE 519 standards. The extracted reference currents are fed to the hysteresis current controller for the generation of pulses toward the inverter switches of DSTATCOM. The DSTATCOM system along with control algorithms have been tested on various loading conditions, i.e., voltage source- and current source-based non-linear loads, induction heating-based loads, and electric arc furnace. The complete DSTATCOM systems were implemented and executed in the MATLAB/Simulink platform and then power quality improvement features were investigated.
引用
收藏
页码:1590 / 1610
页数:21
相关论文
共 23 条
  • [21] Analysis and Control of a Transformerless Series Injector Based on Paralleled H-Bridge Converters for Measuring Impedance of Three-Phase AC Power Systems
    Liu, Zeng
    Cvetkovic, Igor
    Shen, Zhiyu
    Boroyevich, Dushan
    Burgos, Rolando
    Liu, Jinjun
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 1841 - 1845
  • [22] A 3-D PWM control, H-bridge tri-level inverter for power quality compensation in three-phase four-wired systems
    Mak, PI
    Wong, MC
    U, SP
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 5, PROCEEDINGS, 2004, : 948 - 951
  • [23] Comparative Analysis of Conventional and Modified Peak-detection Based Control Technique for Cascaded H-Bridge Multilevel Inverter based Shunt Active Power Filter
    Ray, Soumyadeep
    Gupta, Nitin
    Gupta, R. A.
    2017 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2017,