Fabrication and sensing property for conducting polymer nanowire-based biosensor for detection of immunoglobulin G

被引:7
|
作者
Park, Eun-Sil [1 ]
Jang, Dae-Hwan [1 ]
Lee, Young-In [2 ]
Jung, Chan Woo [3 ]
Lim, Dong Woo [3 ]
Kim, Bum Sung [4 ]
Jeong, Young-keun [5 ]
Myung, Nosang V. [6 ]
Choa, Yong-Ho [1 ]
机构
[1] Hanyang Univ, Dept Fus Chem Engn, Ansan, South Korea
[2] Seoul Natl Univ Sci & Technol, Dept Mat Sci & Engn, Seoul, South Korea
[3] Hanyang Univ, Dept Bionano Engn, Ansan, South Korea
[4] Korea Inst Ind Technol, Inchon, South Korea
[5] Pusan Natl Univ, Natl Core Res Ctr Hybrid Mat Solut, Pusan 609735, South Korea
[6] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
基金
新加坡国家研究基金会;
关键词
Conducting polymer nanowire; Biosensor; Electrospinning; Surface immobilization;
D O I
10.1007/s11164-014-1669-7
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Conducting polymers are excellent sensing materials in the design of bioanalytical sensors because of their electronic conductivity, low energy optical transitions, biocompatibility, and room temperature operation. Among them, Polypyrrole (Ppy) is one of the most extensively used conducting polymers because of a number of properties such as redox activity, rapid electron transfer, and ability to link a variety of biomolecules to pyrrole groups by chemical treatment. In this study, Ppy nanowires were synthesized by an electrospinning method. The nanowires were prepared from a solution mixture of Ppy and poly(ethylene oxide). The method of detection in such a device is based on the selective binding of antigen onto an antibody that is covalently attached to the nanowires. Thus, anti-IgG was immobilized on Ppy nanowires using an EDC {[N-(3-dimethyl aminopropyl)-N-2-ethylcarbodiimide hydrochloride]}-NHS(N-hydrosuccinimide) modified technique. Fluorescence images of BSA-FITC (fluorescein isothiocyanate labeling of bovine serum albumin) conjugation demonstrated that antibody was functionalized on the Ppy nanowires without non-specific binding and facilitated selective detection of antigen. Current-voltage (I-V) characterization was used to monitor the change in the conductivity of nanowires while the specific binding interaction occurred. These results of electrical properties enable Ppy nanowire-based biosensors to detect biomolecules in real-time.
引用
收藏
页码:2565 / 2570
页数:6
相关论文
共 50 条
  • [21] A simple conducting polymer-based biosensor for the detection of atrazine
    El Kaoutit, M
    Bouchta, D
    Zejli, H
    Izaoumen, N
    Temsamani, KR
    ANALYTICAL LETTERS, 2004, 37 (08) : 1671 - 1681
  • [22] Design and Fabrication of Silicon Nanowire-based MEMS Microphones
    Lee, Seunghyun
    Chang, Bobaro
    Kim, Taeyup
    Jin, Ailian
    Cho, Dong-il Dan
    2019 19TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2019), 2019, : 1685 - 1688
  • [23] Electrostatic Limit of Detection of Nanowire-Based Sensors
    Henning, Alex
    Molotskii, Michel
    Swaminathan, Nandhini
    Vaknin, Yonathan
    Godkin, Andrey
    Shalev, Gil
    Rosenwaks, Yossi
    SMALL, 2015, 11 (37) : 4931 - 4937
  • [24] Nanowire-based architectures for the detection of THz radiation
    Vitiello, Miriam S.
    Pitanti, Alessandro
    Teppe, Frederic
    Coquillat, Dominique
    Viti, Leonardo
    Ercolani, Daniele
    Sorba, Lucia
    Knap, Wojciech
    Tredicucci, Alessandro
    2011 36TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2011,
  • [25] Molecularly Imprinted Polyaniline Nanowire-Based Electrochemical Biosensor for Chloramphenicol Detection: A Kinetic Study of Aniline Electropolymerization
    Thi-Xuan Chu
    Van-Phu Vu
    Hong-Thuy Tran
    Thi-Luyen Tran
    Quang-Thinh Tran
    Tu Le Manh
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
  • [26] Integration of microfluidic sample delivery system on silicon nanowire-based biosensor
    Hemmila, Samu
    Gao, Anran
    Lu, Na
    Li, Tie
    Wang, Yuelin
    Kallio, Pasi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (03): : 571 - 580
  • [27] Integration of microfluidic sample delivery system on silicon nanowire-based biosensor
    Samu Hemmilä
    Anran Gao
    Na Lu
    Tie Li
    Yuelin Wang
    Pasi Kallio
    Microsystem Technologies, 2015, 21 : 571 - 580
  • [28] Improving gold nanowire-based biosensor sensitivity by changing probe design
    Cao Huu Tien
    Ha Van Linh
    Pham Xuan Thanh Tung
    Le Van Hieu
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2018, 15 (1-3) : 199 - 209
  • [29] Conducting polymer-based impedimetric aptamer biosensor for in situ detection
    Liao, Wei
    Randall, Brad A.
    Alba, Nicolas A.
    Cui, Xinyan Tracy
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (05) : 861 - 864
  • [30] Conducting polymer-based impedimetric aptamer biosensor for in situ detection
    Wei Liao
    Brad A. Randall
    Nicolas A. Alba
    Xinyan Tracy Cui
    Analytical and Bioanalytical Chemistry, 2008, 392 : 861 - 864