A new analytical device based on gated ion channels: A peptide-channel biosensor

被引:15
|
作者
WeissWichert, C [1 ]
Smetazko, M [1 ]
ValinaSaba, M [1 ]
Schalkhammer, T [1 ]
机构
[1] LUDWIG BOLTZMANN FORSCHUNGSSTELLE BIOCHEM,INST BIOCHEM & MOL CELL BIOL,VIENNA BIOCTR,A-1030 VIENNA,AUSTRIA
关键词
D O I
10.1177/108705719700200104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Binding of a protein at a ligand-modified ion channel can lead to closure or distortion of the channel, resulting in a digital on/off response of the ion flux. This principle could be applied as a strategy for sensor design using artificial membrane ligands or receptors. Important details of modeling and a technique of realization of the new molecular electronic sensor device are presented. The response of the sensor induced by analyte binding depends on the analyte's size and ability to close or distort the ion channel. Testing different ion channels in a typical single molecule-binding event modifies the membrane current by about 0.2 to 20 pA. The gated channel-based sensor is set up by using elements from different fields. It consists of a stable transmembrane channel (for example, a chemically engineered 6.3 helix peptide antibiotic) with a ligand covalently bound at the peptide channel entrance, an electrochemical sensor chip with a photostructurized hydrophobic polymer frame, a hydrophilic ion-conducting membrane support, a lipid membrane incorporating the engineered ion channel, and a sensitive membrane current amplifier or a sensitive fluorescence monitor. Detection of channel opening or closure can either be obtained directly by monitoring membrane conductivity or by monitoring a transient change in pH or ion concentration within the membrane compartment. This transient change can be induced by various means, and its decay is directly correlated to the ion permeability of the membrane. Nonspecific binding at a lipid membrane does not interfere with the ion flux through ion channels. This is a basic advantage of this principle compared to that of enzyme-linked immunosorbent assay (ELISA), radioimmunoassay (RIA), or hybridization of labeled DNA/RNA probes. Furthermore, because nonspecific binding events are mainly transient, specific binding events directly at the ion channel can be separated from them by evaluating the current peak time scale. Theoretically, the sensitivity of such a device can approach one molecule. Under practical conditions, the sensitivity is limited by the diffusion process of the analyte to the receptor ligand but not by the molecular electronic device. The new type of biosensor combines sensor design and technology from immunoassays and biorecognition assays with automated analysis systems and knowledge from the field of nanotechnology. Based on the detection principle, miniaturized portable sensor chips with either electronic or optical detection are under construction. These may have capabilities exceeding those of existing analytical instruments (for example, ELISA tests, medical analyzer, and high-pressure liquid chromatography [HPLC].
引用
收藏
页码:11 / 18
页数:8
相关论文
共 50 条
  • [31] A NEW LOOK AT THE MECHANISM OF ACTIVATION AND INACTIVATION OF VOLTAGE-GATED ION CHANNELS
    KEYNES, RD
    PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1992, 249 (1324) : 107 - 112
  • [32] Three Homologous Subunits Form a High Affinity Peptide-gated Ion Channel in Hydra
    Duerrnagel, Stefan
    Kuhn, Anne
    Tsiairis, Charisios D.
    Williamson, Michael
    Kalbacher, Hubert
    Grimmelikhuijzen, Cornelis J. P.
    Holstein, Thomas W.
    Gruender, Stefan
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2010, 285 (16) : 11958 - 11965
  • [33] A delta-sigma approach for ion channel based biosensor arrays
    Bennati, M.
    Lodesani, F.
    Crescentini, M.
    Mariani, A.
    Tartagni, M.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [34] Incubation type Si-based planar ion channel biosensor
    Tsuneo Urisu
    Toshifumi Asano
    Zhenlong Zhang
    Hidetaka Uno
    Ryugo Tero
    Han Junkyu
    Isoda Hiroko
    Yusuke Arima
    Hiroo Iwata
    Koji Shibasaki
    Makoto Tominaga
    Analytical and Bioanalytical Chemistry, 2008, 391 : 2703 - 2709
  • [35] Developments of Si based planer type ion-channel biosensor
    Urisu, Tsuneo
    PROGRESS ON POST-GENOME TECHNOLOGIES, 2007, : 14 - 16
  • [36] Incubation type Si-based planar ion channel biosensor
    Urisu, Tsuneo
    Asano, Toshifumi
    Zhang, Zhenlong
    Uno, Hidetaka
    Tero, Ryugo
    Junkyu, Han
    Hiroko, Isoda
    Arima, Yusuke
    Iwata, Hiroo
    Shibasaki, Koji
    Tominaga, Makoto
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (08) : 2703 - 2709
  • [37] Monolayer-gated Ion Transport in Artificial Ion Channels Based on A Nanoporous Gold Membrane
    Yan, Nana
    Xiao, Tianliang
    Liu, Zhaoyue
    ACTA CHIMICA SINICA, 2017, 75 (09) : 873 - 877
  • [38] THE ION-CHANNEL REGION OF THE LIGAND-GATED-ION-CHANNELS - AN ALTERNATIVE MODEL TO AN ALL-HELIX STRUCTURE
    ORTELLS, M
    LUNG, GG
    JOURNAL OF NEUROCHEMISTRY, 1995, 65 : S72 - S72
  • [39] Immunosensing arrays based on tethered lipid membranes and gated ion channels.
    Cornell, B
    Drane, G
    Fiddes, R
    Jennings, P
    Becker, T
    CasCao-Peraria, L
    Fujdala, M
    Gebert, M
    Lee, SK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U637 - U637
  • [40] Solid-state nanopore based biomimetic voltage gated ion channels
    Pevarnik, Matthew
    Cui, Weibin
    Yemenicioglu, Sukru
    Rofeh, Justin
    Theogarajan, Luke
    BIOINSPIRATION & BIOMIMETICS, 2017, 12 (06)