B-Flow and B-Mode Ultrasound Imaging in Carotid Fibromuscular Dysplasia

被引:7
|
作者
Cutler, Joshua J. [1 ]
Campo, Nelly [1 ]
Koch, Sebastian [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Neurol, Miami, FL 33136 USA
关键词
Ultrasound; fibromuscular dysplasia; carotid; B-flow; B-mode; ARTERY;
D O I
10.1111/jon.12498
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Previous ultrasound studies in fibromuscular dysplasia (FMD) have largely reported on color flow imaging, power Doppler, and Doppler flow augmentation. We here report on arterial wall imaging findings by B-flow and B-mode in patients with carotid FMD. METHODS: We retrospectively reviewed ultrasonographic findings in subjects with known or suspected FMD. All patients were evaluated with a standardized imaging protocol including Doppler, B-mode, and B-flow. Vessel wall abnormalities were classified as normal, luminal irregularities, or classical beading (fusiform dilatations). RESULTS: We identified 23 patients and 33 carotid arteries were found to be abnormal, of which 10 had classical beading and 23 showed endoluminal irregularities. Bilateral disease was present in 10/23 patients. In the classical beading cases, B-mode revealed isoechoic ridges, which protruded into the lumen, alternating with dilated arterial segments, which were also clearly demonstrated by B-flow imaging. In cases with endoluminal irregularities, B-mode and B-flow showed isoechoic subendothelial irregular thickening, which did not lead to a fusiform dilatory appearance of the artery. The average distal internal carotid artery peak systolic velocity of arteries with classical beading (123 +/- 29 cm/second) was significantly greater than that of arteries with mild irregularities (94 +/- 34 cm/second) (P = .024). CONCLUSION: Morphological arterial wall changes of FMD were well depicted by careful B-flow and B-mode imaging of the distal internal carotid artery. We would like to emphasize the utility of B-flow and B-mode in the noninvasive evaluation of FMD.
引用
收藏
页码:269 / 272
页数:4
相关论文
共 50 条
  • [21] Carotid Artery Plaque Composition Relationship to Clinical Presentation and Ultrasound B-mode Imaging Commentary
    Golledge, J.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 42 : S39 - S40
  • [22] B-Flow imaging in low cervical internal carotid artery dissection
    Tola, M
    Yurdakul, M
    Cumhur, T
    JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (11) : 1497 - 1502
  • [23] Comparison of B-mode ultrasound, 3-dimensional ultrasound, and magnetic resonance imaging measurements of carotid atherosclerosis
    Egger, Micaela
    Krasinski, Adam
    Rutt, Brian K.
    Fenster, Aaron
    Parraga, Grace
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (09) : 1321 - 1334
  • [24] NONLINEAR PROCESSING IN B-MODE ULTRASOUND AFFECTS CAROTID DIAMETER ASSESSMENT
    Rossi, Alessandro C.
    Brands, Peter J.
    Hoeks, Arnold P. G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (05): : 736 - 747
  • [25] Automatic detection of the carotid lumen axis in B-mode ultrasound images
    Rocha, Rui
    Silva, Jorge
    Campilho, Aurelio
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 115 (03) : 110 - 118
  • [26] CAROTID B-MODE SCANNING - ALTERNATIVE OR ADDITION TO ULTRASOUND DOPPLER SONOGRAPHY
    RINGELSTEIN, EB
    KOLMANN, HL
    ZEUMER, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (24) : 928 - 933
  • [27] B-MODE ULTRASOUND EXAMINATION AND PLATELET SCINTIGRAPHY OF THE CAROTID-ARTERY
    KESSLER, C
    NERVENHEILKUNDE, 1989, 8 (01) : 22 - 26
  • [28] Robust Carotid Artery Recognition in Longitudinal B-Mode Ultrasound Images
    Sifakis, Emmanouil G.
    Golemati, Spyretta
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2014, 23 (09) : 3762 - 3772
  • [29] Carotid Wall Motion Analysis Based on B-Mode Ultrasound Images
    Hopkins, Warren
    Gao, Hao
    Das, Saroj
    Long, Quan
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 871 - 874
  • [30] Automatic segmentation of the lumen of the carotid artery in ultrasound B-mode images
    Santos, Andre M. F.
    Tavares, Joao Manuel R. S.
    Sousa, Luisa
    Santos, Rosa
    Castro, Pedro
    Azevedo, Elsa
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670