Study of the Bus Voltage Magnitude to Monitor Power Quality in the Distribution System

被引:1
|
作者
Men, Christopher R. [1 ]
Dow, Douglas E. [1 ]
Ghanavati, Afsaneh [1 ]
机构
[1] Wentworth Inst Technol, Sch Engn, Elect & Comp Engn Program, Boston, MA 02115 USA
关键词
CBEMA curve; ITIC curve; RMS voltage; sags; swells; graphical user interface (GUI); power quality metric; MATLAB;
D O I
10.1109/EPEC56903.2022.10000155
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Power quality disturbances can be observed as sags, swells, transients, and harmonics, and can affect customers at varying levels of intensity. It is the responsibility of the utility to supply customers with power, however power quality disruptions can occur during distribution. Traditionally, only voltage information is used to conduct power quality monitoring at the distribution level. It is common to record the RMS values of the bus voltages and to identify abnormal operations based on when a sag or swell occurs. This paper proposes a tool consisting of an algorithm and an accompanying graphical user interface (GUI) that can display historical voltage bus data, analyze the data, and provide the user with information that details voltage behavior outside of a user-defined threshold. The GUI gives the user the interactive ability to import data and set the desired threshold. The algorithm then detects events in the imported data outside of the chosen threshold. It also provides the user with event durations, magnitudes, local maximums, and area. The efficacy of the algorithm was verified by comparing the output determined by the algorithm versus the conclusion drawn by a human observer. Additionally, this paper provides a brief overview of two power quality curves: the Computer and Business Equipment Manufacturers' Association (CBEMA) curve, and the Information Technology Industry Council (ITIC) curve. These curves have been utilized in past decades as the common mechanisms to identify voltage variations and the duration of disturbances. Although these curves have proven to have great merit for use as tolerance curves, they may not capture all the necessary details of the events for power quality characterization.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 50 条
  • [31] Estimation of Voltage Unbalance at the Reference Bus in Distribution System State Estimation
    Pereira de Melo, Vitor Henrique
    Massignan, Julio A. D.
    London Junior, Joao B. A.
    Fanucchi, Rodrigo Z.
    2021 IEEE MADRID POWERTECH, 2021,
  • [32] RMS voltage variation statistical analysis for a survey of distribution system power quality performance
    Sabin, DD
    Grebe, TE
    Sundaram, A
    IEEE POWER ENGINEERING SOCIETY - 1999 WINTER MEETING, VOLS 1 AND 2, 1999, : 1235 - 1240
  • [33] Power System Clustering Islanding Method Considering Bus Voltage Controllability
    Xu Wei-ting
    Ren Zhi-chao
    Tang Quan
    Chen Li-Pin
    Cao Kai-jiang
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [34] Cost effective voltage surge protection on a space system power bus
    Clark, OM
    PROCEEDINGS OF THE FIFTH EUROPEAN SPACE POWER CONFERENCE (ESPC), VOLS 1 AND 2, 1998, 416 : 399 - 405
  • [35] Application of wavelet transform for assessing power quality in medium voltage industrial distribution system
    El-Saadany, EF
    Abdel-Galil, TK
    Salama, MMA
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 427 - 432
  • [36] Development of a Resonance-Free Power Quality Controller for Middle Voltage Distribution System
    Lei Wanjun
    Wang Yue
    Luo Wen
    Zhang Leqiang
    Su Ninghuan
    Zheng Ming
    Wang Zhaoan
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 3539 - 3543
  • [37] Current Mode Control of Dynamic Voltage Restorer for Power Quality Improvement in Distribution System
    Jayaprakash, P.
    Singh, Bhim
    Kothari, D. P.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 301 - +
  • [38] Distribution system power quality assessment phase II: Voltage sag and interruption analysis
    Melhorn, CJ
    Maitra, A
    Sunderman, W
    Waclawiak, M
    Sundaram, A
    Industry Applications Society 52nd Annual Petroleum and Chemical Industry Conference, 2005, : 113 - 120
  • [39] Variable-Voltage Bus Concept for Aircraft Electrical Power System
    Yeoh, Seang Shen
    Rashed, Mohamed
    Sanders, Mike
    Bozhko, Serhiy
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (07) : 5634 - 5643
  • [40] Comparative study on power quality disturbance magnitude characterization
    Wang, ZQ
    Zhu, SZ