Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry

被引:31
|
作者
Nakazono, Yukiko [1 ,2 ]
Tsujikawa, Kenji [1 ]
Kuwayama, Kenji [1 ]
Kanamori, Tatsuyuki [1 ]
Iwata, Yuko T. [1 ]
Miyamoto, Kazuna [2 ,3 ]
Kasuya, Fumiyo [3 ]
Inoue, Hiroyuki [1 ]
机构
[1] Natl Res Inst Police Sci, Kashiwa, Chiba 2770882, Japan
[2] Hitec Inc, Chuo Ku, Chiba 2600045, Japan
[3] Kobe Gakuin Univ, Biochem Toxicol Lab, Fac Pharmaceut Sci, Chuo Ku, Kobe, Hyogo 6508586, Japan
关键词
Fluoroamphetamine analogs; Regioisomer; Designer drug; GC-MS; LC-MS; DESIGNER DRUGS; SERIES; BRAIN; RAT;
D O I
10.1007/s11419-013-0184-7
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
In recent years, a large number of clandestinely produced controlled-substance analogs (designer drugs) of amphetamine with high structural variety have been detected in forensic samples. Analytical differentiation of regioisomers is a significant issue in forensic drug analysis because, in most cases, legal controls are placed only on one or two of the three isomers. In this study, we used gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the differentiation of regioisomers of fluoroamphetamine analogs (fluoroamphetamines and fluoromethamphetamines), which were synthesized in our laboratories. Free bases and their acylated and silylated derivatives were subjected to GC-MS analysis using DB-1ms, DB-5ms, and DB-17ms capillary columns. The separation of free bases was incomplete on all columns. Trifluoroacetyl derivatives of 3- and 4-positional isomers showed slight separation on DB-1ms and DB-5ms. On the other hand, trimethylsilyl derivatization enabled baseline separation of six fluoroamphetamine analogs on DB-1ms and DB-5ms columns, which was sufficient for unequivocal identification. For LC-MS/MS, a pentafluorophenyl column was able to separate six regioisomeric fluoroamphetamine analogs but a conventional C18 column could not achieve separation between 3- and 4-positional isomers. These results show that a suitable choice of derivatization and analytical columns allows the differentiation of regioisomeric fluoroamphetamine analogs.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 50 条
  • [11] Quantitative Analysis of Tetramethylenedisulfotetramine (Tetramine) Spiked into Beverages by Liquid Chromatography-Tandem Mass Spectrometry with Validation by Gas Chromatography-Mass Spectrometry
    Owens, Janel
    Hok, Saphon
    Alcaraz, Armando
    Koester, Carolyn
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (10) : 4058 - 4067
  • [12] Liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry determination of N-methylpyrrolidinone in riverine biofilms
    Headley, JV
    Peru, KM
    Friesen, DA
    Neu, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 917 (1-2) : 159 - 165
  • [13] Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry
    Shoji, Y
    Yotsu-Yamashita, M
    Miyazawa, T
    Yasumoto, T
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) : 10 - 17
  • [14] Identification and differentiation of methcathinone analogs by gas chromatography-mass spectrometry
    Tsujikawa, Kenji
    Mikuma, Toshiyasu
    Kuwayama, Kenji
    Miyaguchi, Hajime
    Kanamori, Tatsuyuki
    Iwata, Yuko T.
    Inoue, Hiroyuki
    [J]. DRUG TESTING AND ANALYSIS, 2013, 5 (08) : 670 - 677
  • [15] Urinary screening for methylphenidate (Ritalin) abuse: a comparison of liquid chromatography-tandem mass spectrometry, gas chromatography-mass spectrometry, and immunoassay methods
    Eichhorst, J
    Etter, M
    Lepage, J
    Lehotay, DC
    [J]. CLINICAL BIOCHEMISTRY, 2004, 37 (03) : 175 - 183
  • [16] Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify α-tocopherol and α-tocopherolquinone levels in human plasma
    Mottier, P
    Gremaud, E
    Guy, PA
    Turesky, RJ
    [J]. ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 128 - 135
  • [17] Differentiation of ring-substituted bromoamphetamine analogs by gas chromatography-tandem mass spectrometry
    Inoue, Hiroyuki
    Negishi, Shoko
    Nakazono, Yukiko
    Iwata, Yuko T.
    Tsujikawa, Kenji
    Ohtsuru, Osamu
    Miyamoto, Kazuna
    Yamashita, Takuya
    Kasuya, Fumiyo
    [J]. FORENSIC TOXICOLOGY, 2016, 34 (01) : 125 - 132
  • [18] Differentiation of regioisomeric chloroamphetamine analogs using gas chromatography–chemical ionization-tandem mass spectrometry
    Shoko Negishi
    Yukiko Nakazono
    Yuko T. Iwata
    Tatsuyuki Kanamori
    Kenji Tsujikawa
    Kenji Kuwayama
    Tadashi Yamamuro
    Kazuna Miyamoto
    Takuya Yamashita
    Fumiyo Kasuya
    Hiroyuki Inoue
    [J]. Forensic Toxicology, 2015, 33 : 338 - 347
  • [19] Carbohydrate profiling of bacteria by gas chromatography-mass spectrometry and their trace detection in complex matrices by gas chromatography-tandem mass spectrometry
    Fox, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) : 287 - 300
  • [20] Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry
    Lipicar, Eva
    Fras, Danijela
    Javernik, Nino
    Prosen, Helena
    [J]. TOXICS, 2023, 11 (01)