Measurement of the transfer function for a spoke cavity of C-ADS Injector I

被引:0
|
作者
Huang, Xue-Fang [1 ,2 ]
Sun, Yi [2 ]
Wang, Guang-Wei [2 ]
Wang, Shao-Zhe [1 ,2 ]
Zheng, Xiang [3 ]
Wang, Qun-Yao [2 ]
Liu, Rong [2 ]
Lin, Hai-Ying [2 ]
Wang, Mu-Yuan [1 ,2 ]
机构
[1] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
关键词
Spoke012; Lorentz transfer function; piezo fast tuner transfer function; mechanical eigenmodes;
D O I
10.1088/1674-1137/41/4/047001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The spoke cavities mounted in the China Accelerator Driven sub-critical System (C-ADS) have high quality factor (Q) and very small bandwidth, making them very sensitive to mechanical perturbations, whether external or self-induced. The transfer function is used to characterize the response of the cavity eigenfrequency to the perturbations. This paper describes a method to measure the transfer function of a spoke cavity. The measured Lorentz transfer function shows there are 206 Hz and 311 Hz mechanical eigenmodes excited by Lorentz force in the cavity of C-ADS, and the measured piezo fast tuner transfer function shows there are 12 mechanical eigenmodes from 0 to 500 Hz. According to these results, some effective measures have been taken to weaken the influence of helium pressure fluctuation, avoid mechanical resonances and improve the reliability of the RF system.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Study on the selection of BLM detector for C-ADS Injector Ⅱ
    任广益
    曾鸣
    何源
    李裕熊
    李为民
    Chinese Physics C, 2014, (11) : 74 - 77
  • [12] Flow performance of cryomodules in C-ADS Injector.
    Wan, Yu-Qin
    Han, Yan-Ning
    Zhang, Jun-Hui
    Li, Chao
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2022, 24 (03): : 74 - 78
  • [13] Study on the selection of BLM detector for C-ADS Injector Ⅱ
    任广益
    曾鸣
    何源
    李裕熊
    李为民
    Chinese Physics C, 2014, 38 (11) : 74 - 77
  • [14] Error analysis and lattice improvement for the C-ADS Injector-Ⅰ
    孟才
    李智慧
    唐靖宇
    Chinese Physics C, 2014, 38 (06) : 118 - 122
  • [15] Study on the selection of BLM detector for C-ADS Injector II
    Ren Guang-Yi
    Zeng Ming
    He Yuan
    Li Yu-Xiong
    Li Wei-Min
    CHINESE PHYSICS C, 2014, 38 (11)
  • [16] Error analysis and lattice improvement for the C-ADS Injector-Ⅰ
    孟才
    李智慧
    唐靖宇
    Chinese Physics C, 2014, (06) : 118 - 122
  • [17] Design of RF coupler for C-ADS injector II RFQ
    Shi, Ai-Min
    Sun, Lie-Peng
    Zhang, Zhou-Li
    He, Yuan
    Lu, Liang
    Li, Chen-Xing
    Xu, Xian-Bo
    Shi, Long-Bo
    Wang, Wen-Bin
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 : 539 - 542
  • [18] Longitudinal instability caused by long driftsin the C-ADS injector-Ⅰ
    李智慧
    唐靖宇
    闫芳
    耿会平
    孟才
    孙彪
    程鹏
    郭臻
    孙纪磊
    Chinese Physics C, 2013, 37 (03) : 101 - 105
  • [19] Beam-based calibrations of the BPM offset at C-ADS Injector Ⅱ
    陈伟龙
    王志军
    冯驰
    窦为平
    陶玥
    贾欢
    王旺生
    刘淑会
    何源
    Chinese Physics C, 2016, 40 (07) : 162 - 165
  • [20] Beam-based calibrations of the BPM offset at C-ADS Injector Ⅱ
    陈伟龙
    王志军
    冯驰
    窦为平
    陶玥
    贾欢
    王旺生
    刘淑会
    何源
    Chinese Physics C, 2016, (07) : 162 - 165