Measurement of the transfer function for a spoke cavity of C-ADS Injector I

被引:0
|
作者
Huang, Xue-Fang [1 ,2 ]
Sun, Yi [2 ]
Wang, Guang-Wei [2 ]
Wang, Shao-Zhe [1 ,2 ]
Zheng, Xiang [3 ]
Wang, Qun-Yao [2 ]
Liu, Rong [2 ]
Lin, Hai-Ying [2 ]
Wang, Mu-Yuan [1 ,2 ]
机构
[1] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
关键词
Spoke012; Lorentz transfer function; piezo fast tuner transfer function; mechanical eigenmodes;
D O I
10.1088/1674-1137/41/4/047001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The spoke cavities mounted in the China Accelerator Driven sub-critical System (C-ADS) have high quality factor (Q) and very small bandwidth, making them very sensitive to mechanical perturbations, whether external or self-induced. The transfer function is used to characterize the response of the cavity eigenfrequency to the perturbations. This paper describes a method to measure the transfer function of a spoke cavity. The measured Lorentz transfer function shows there are 206 Hz and 311 Hz mechanical eigenmodes excited by Lorentz force in the cavity of C-ADS, and the measured piezo fast tuner transfer function shows there are 12 mechanical eigenmodes from 0 to 500 Hz. According to these results, some effective measures have been taken to weaken the influence of helium pressure fluctuation, avoid mechanical resonances and improve the reliability of the RF system.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Measurement of the transfer function for a spoke cavity of C-ADS Injector I
    黄雪芳
    孙毅
    王光伟
    王少哲
    郑湘
    王群要
    刘熔
    林海英
    王牧源
    Chinese Physics C, 2017, (04) : 161 - 165
  • [2] Thermal performance analysis and operation of the spoke cavity cryomodules for C-ADS Injector-I
    Han, Ruixiong
    Zou, Zhengping
    Ge, Rui
    Li, Shaopeng
    Bian, Lin
    Sun, Liangrui
    Sang, Minjing
    Ye, Rui
    Peng, Quanling
    Zhang, Xiangzhen
    Zhang, Jianqin
    Zhang, Zhuo
    Zhang, Jiehao
    Xu, Miaofu
    Chang, Zhengze
    Huang, Tongming
    He, Feisi
    Liu, Chenglian
    CRYOGENICS, 2019, 101 : 63 - 74
  • [3] Tuner control system of Spoke012 SRF cavity for C-ADS injector I
    刘娜
    孙毅
    王光伟
    米正辉
    林海英
    王群要
    刘熔
    马新朋
    Chinese Physics C, 2016, (09) : 142 - 147
  • [4] Tuner control system of Spoke012 SRF cavity for C-ADS injector I
    刘娜
    孙毅
    王光伟
    米正辉
    林海英
    王群要
    刘熔
    马新朋
    Chinese Physics C, 2016, 40 (09) : 142 - 147
  • [5] Tuner control system of Spoke012 SRF cavity for C-ADS injector I
    Liu, Na
    Sun, Yi
    Wang, Guang-Wei
    Mi, Zheng-Hui
    Lin, Hai-Ying
    Wang, Qun-Yao
    Liu, Rong
    Ma, Xin-Peng
    CHINESE PHYSICS C, 2016, 40 (09)
  • [6] Error analysis and lattice improvement for the C-ADS Injector-I
    Meng Cai
    Li Zhi-Hui
    Tang Jing-Yu
    CHINESE PHYSICS C, 2014, 38 (06)
  • [7] Compensation-rematch for the major components of C-ADS injector-I
    孙彪
    闫芳
    裴士伦
    孟才
    唐靖宇
    Chinese Physics C, 2015, 39 (11) : 103 - 108
  • [8] Compensation-rematch for the major components of C-ADS injector-I
    Sun Biao
    Yan Fang
    Pei Shi-Lun
    Meng Cai
    Tang Jing-Yu
    CHINESE PHYSICS C, 2015, 39 (11)
  • [9] Compensation-rematch for the major components of C-ADS injector-I
    孙彪
    闫芳
    裴士伦
    孟才
    唐靖宇
    Chinese Physics C, 2015, (11) : 103 - 108
  • [10] Longitudinal instability caused by long drifts in the C-ADS injector- I
    Li Zhi-Hui
    Tang Jing-Yu
    Yang Fang
    Geng Hui-Ping
    Meng Cai
    Sun Biao
    Cheng Peng
    Guo Zhen
    Sun Ji-Lei
    CHINESE PHYSICS C, 2013, 37 (03)