In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy

被引:492
|
作者
Izatt, JA [1 ]
Kulkami, MD [1 ]
Yazdanfar, S [1 ]
Barton, JK [1 ]
Welch, AJ [1 ]
机构
[1] UNIV TEXAS,BIOMED ENGN PROGRAM,AUSTIN,TX 78712
关键词
D O I
10.1364/OL.22.001439
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-mu m spatial resolution and <0.6-mm/s velocity precision were obtained through intact shin in living hamster subdermal tissue. This technology has several potential medical applications. (C) 1997 Optical Society of America.
引用
收藏
页码:1439 / 1441
页数:3
相关论文
共 50 条
  • [31] Doppler flow imaging of perfusion in the rat retina and choroid using optical coherence tomography
    Glucksberg, MR
    Wu, FI
    Geiger, RC
    Izatt, JA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S976 - S976
  • [32] Imaging of fluid flow velocity using Doppler optical coherence tomography: preliminary results
    Piao, DQ
    Chen, NG
    Zhu, Q
    Dutta, NK
    Otis, LL
    [J]. PROCEEDINGS OF THE IEEE 27TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2001, : 55 - 56
  • [33] Three-dimensional reconstruction of blood vessels from in vivo color Doppler optical coherence tomography images
    Barton, JK
    Izatt, JA
    Kulkarni, MD
    Yazdanfar, S
    Welch, AJ
    [J]. DERMATOLOGY, 1999, 198 (04) : 355 - 361
  • [34] In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth
    Yao, Junjie
    Maslov, Konstantin I.
    Shi, Yunfei
    Taber, Larry A.
    Wang, Lihong V.
    [J]. OPTICS LETTERS, 2010, 35 (09) : 1419 - 1421
  • [35] Comparison of transvaginal color Doppler imaging and color Doppler energy for assessment of intraovarian blood flow
    Tailor, A
    Jurkovic, D
    Bourne, TH
    Natucci, M
    Collins, WP
    Campbell, S
    [J]. OBSTETRICS AND GYNECOLOGY, 1998, 91 (04): : 561 - 567
  • [36] In vivo endoscopic Doppler optical coherence tomography imaging of mouse colon
    Welge, Weston A.
    Barton, Jennifer K.
    [J]. ENDOSCOPIC MICROSCOPY XI; AND OPTICAL TECHNIQUES IN PULMONARY MEDICINE III, 2016, 9691
  • [37] Blood flow assessed by color Doppler imaging in retinopathy of prematurity
    Hartenstein, S.
    Mueller, B.
    Metze, B.
    Czernik, C.
    Buehrer, C.
    [J]. JOURNAL OF PERINATOLOGY, 2015, 35 (09) : 745 - 747
  • [38] INTRAOPERATIVE COLOR DOPPLER IMAGING OF CARDIAC BLOOD-FLOW
    HILLEL, Z
    THYS, D
    GOLDMAN, M
    RITTER, S
    ERGIN, A
    GRIEPP, R
    KAPLAN, J
    [J]. ANESTHESIOLOGY, 1986, 65 (3A) : A169 - A169
  • [39] Blood flow assessed by color Doppler imaging in retinopathy of prematurity
    S Hartenstein
    B Müller
    B Metze
    C Czernik
    C Bührer
    [J]. Journal of Perinatology, 2015, 35 : 745 - 747
  • [40] High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography
    van Leeuwen, TG
    Kulkarni, MD
    Yazdanfar, S
    Rollins, AM
    Izatt, JA
    [J]. OPTICS LETTERS, 1999, 24 (22) : 1584 - 1586