Radiological evaluation of C1 pedicle screw anatomic feasibility

被引:6
|
作者
Dawes, Bryden [1 ]
Perchyonok, Yuliya [2 ,3 ]
Gonzalvo, Augusto [1 ,3 ]
机构
[1] Austin Hlth, Dept Neurosurg, 145 Studley Rd, Heidelberg, Vic 3070, Australia
[2] Austin Hlth, Dept Radiol, 145 Studley Rd, Heidelberg, Vic 3070, Australia
[3] Univ Melbourne, Parkville, Vic 3010, Australia
关键词
Atlas; C1; vertebra; Cervical pedicle screws; Cervical posterior fixation; Internal fixation; LATERAL MASS SCREWS; POSTERIOR ARCH; PLACEMENT; FIXATION; INSERTION;
D O I
10.1016/j.jocn.2018.01.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
C1 pedicle screw instrumentation is a recently documented technique, which may have benefits over other more popularised procedures, however it may not be possible in all patients. This study aims to investigate the applicability of the C1 pedicle screw technique to a cohort of patients through assessment of radiological parameters. A retrospective review of 150 consecutive patients undergoing computer tomography (CT) of the cervical spine was performed. Based on defined parameters images were assessed for feasibility of placement of pedicle screws. C1 pedicle height (PH), pedicle width (PW), screw trajectory length (LML) and width (LMW) were recorded with PH >= 4 mm defined as the primary outcome measure. A total of 115 patients and 230 C1 pedicles were examined. The mean PH was found to be 5.1 mm. 207 pedicles were deemed suitable for placement of pedicle screw instrumentation. Overall C1 pedicle screw instrumentation was deemed possible in 94.6% of male pedicles and 84% of female pedicles. C1 pedicle screw instrumentation is feasible to be performed in more than 90% of the patients. Crown Copyright (C) 2018 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:18 / 21
页数:4
相关论文
共 50 条
  • [21] C1 Titanium Cables Combined with C2 Pedicle Screw-Rod Fixation for Atlantoaxial Instability Not Suitable for Placement of C1 Screws
    Zhang, Jie-Hong
    Zhang, Zhi-Jing
    Zhu, Ya
    Shi, Jian-Dong
    Li, Bin
    Lu, Yi-Sheng
    WORLD NEUROSURGERY, 2018, 120 : E453 - E456
  • [22] Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability
    Xie, Yang
    Li, Zhonghai
    Tang, Hao
    Li, Ming
    Guan, Zhengmao
    JOURNAL OF CLINICAL NEUROSCIENCE, 2009, 16 (12) : 1592 - 1594
  • [23] Anatomic Determination of Optimal Entry Point and Direction For C1 Lateral Mass Screw Placement
    Blagg, Stuart E.
    Don, Angus S.
    Robertson, Peter A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (04): : 233 - 239
  • [24] Anatomic consideration of C2 pedicle screw placement - Point of view
    Abumi, K
    SPINE, 1996, 21 (06) : 694 - 695
  • [25] Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?
    Da-Geng Huang
    Si-Min He
    Jun-Wei Pan
    Hua Hui
    Hui-Min Hu
    Bao-Rong He
    Hui Li
    Xue-Fang Zhang
    Ding-Jun Hao
    European Spine Journal, 2014, 23 : 1109 - 1114
  • [26] Feasibility and limitations of C1 lateral mass screw placement in patients of atlas assimilation
    Jian, Feng-Zeng
    Su, Chun-Hai
    Chen, Zan
    Wang, Xing-Wen
    Ling, Feng
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 590 - 596
  • [27] Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique
    Lee, Hyung Rae
    Lee, Dong-Ho
    Cho, Jae Hwan
    Hwang, Eui Seung
    Seok, Sang Yun
    Park, Sehan
    Lee, Choon Sung
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (05) : 822 - 829
  • [28] Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?
    Huang, Da-Geng
    He, Si-Min
    Pan, Jun-Wei
    Hui, Hua
    Hu, Hui-Min
    He, Bao-Rong
    Li, Hui
    Zhang, Xue-Fang
    Hao, Ding-Jun
    EUROPEAN SPINE JOURNAL, 2014, 23 (05) : 1109 - 1114
  • [29] Evaluation of the Efficacy of Titanium Mesh Cages with Posterior C1 Lateral Mass and C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Yi, Hyoung-Joong
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2016, 90 : 103 - 108
  • [30] Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw–rod fixation for atlantoaxial instability
    Lei Shi
    Kai Shen
    Rui Deng
    Zheng-Jian Yan
    Kai-Lu Liang
    Liang Chen
    Zhen-Yong Ke
    Zhong-Liang Deng
    European Spine Journal, 2019, 28 : 362 - 369