A novel method for fault location based on two-terminal unsynchronized data

被引:0
|
作者
Li, Xun [1 ]
Gong, Qingwu [1 ]
Ming, Ruiqing [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan, Peoples R China
关键词
fault location; unsynchronized data; self regulating; wavelet transform; simulation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel fault location algorithm has been proposed in this paper based on two-terminal unsynchronized data. This algorithm takes advantage of the characteristics of wavelet transform which can detect the singularity of signal to analyze two-terminal sampled data so as to find the beginning moment of two-terminal fault and calculate the unsynchronized angle, and then further calculate the location of fault. The results show that this method can effectively offset the impact of two-terminal unsynchronized data on fault location. Even if the GPS has been ineffective for a long time, this algorithm can also locate the fault precisely.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Unsynchronized two-terminal fault location estimation
    Novosel, D
    Hart, DG
    Udren, E
    Garitty, J
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 130 - 138
  • [2] An iterative two-terminal fault-location method based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zuern, Hans Helmut
    Seara, Rui
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2318 - 2329
  • [3] A two-terminal fault location approach based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zurn, Hans Helmut
    Seara, Rui
    [J]. 2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2624 - 2630
  • [4] An Unsynchronized Measurements Correction Method for Two-Terminal Fault-Location Problems
    Yu, Chi-Shan
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1325 - 1333
  • [5] Real-Time Traveling-Wave-Based Fault Location Using Two-Terminal Unsynchronized Data
    Lopes, F. V.
    Silva, K. M.
    Costa, F. B.
    Neves, W. L. A.
    Fernandes, D., Jr.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1067 - 1076
  • [6] New Fault Impedance Computations for Unsynchronized Two-Terminal Fault-Location Computations
    Yu, Chi-Shan
    Chang, Li-Ren
    Cho, Jr-Ru
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2879 - 2881
  • [7] A Fault Location Method for Hybrid Lines Based on Two-terminal Asynchronous Data
    Deng W.
    Lu J.
    Shi J.
    Zhong L.
    He Q.
    [J]. Deng, Wenling (727878713@qq.com), 1600, Power System Technology Press (45): : 1574 - 1580
  • [8] Settings-Free Traveling-Wave-Based Earth Fault Location Using Unsynchronized Two-Terminal Data
    Lopes, Felipe
    [J]. 2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [9] Settings-Free Traveling-Wave-Based Earth Fault Location Using Unsynchronized Two-Terminal Data
    Lopes, Felipe V.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (05) : 2296 - 2298
  • [10] Two-terminal asynchronous data fault location algorithm based on improved parameter detection method
    [J]. Gao, Houlei, 1600, Electric Power Automation Equipment Press (34):