Contrast Sensitivity Evaluation of Aspheric and Spherical Intraocular Lenses 2 Years After Implantation

被引:16
|
作者
Caporossi, Aldo [1 ]
Casprini, Fabrizio [1 ]
Martone, Gianluca [1 ]
Balestrazzi, Angelo [1 ]
Tosi, Gian Marco [1 ]
Ciompi, Leonardo [1 ]
机构
[1] Univ Siena, Dept Ophthalmol & Neurosurg, I-53100 Siena, Italy
关键词
POSTERIOR CAPSULE OPACIFICATION; CATARACT-SURGERY; VISUAL PERFORMANCE; GLARE DISABILITY; OPTICAL-QUALITY; HUMAN EYE; ABERRATION; ACUITY; DESIGN; SILICONE;
D O I
10.3928/1081597X-20090610-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the quality of vision with aspheric and spherical intraocular lenses (IOLs) in pseudophakic patients after long-term follow-up. METHODS: Two hundred eyes of 100 patients with bilateral cataracts were randomly assigned to receive spherical (Acrysof SN60AT [Alcon Laboratories Inc] or Sensar AR40e [Advanced Medical Optics Inc)) or aspheric IOLs (Acrysof SN60WF [Alcon] or Tecnis Z9000 [Advanced Medical Optics]). Ophthalmologic examination, including best spectacle-corrected visual acuity (BSCVA), pupil size, ocular dominance, contrast sensitivity under mesopic and photopic conditions, and wavefront analysis, was performed 2 months and 1 and 2 years after surgery. RESULTS: No statistically significant differences among the four groups in terms of age, pupil diameter, postoperative BSCVA, corneal spherical aberration, and posterior capsular opacification were noted. At all followup examinations, contrast sensitivity results showed no significant differences between the two aspheric IOLs at all spatial frequencies. Under photopic conditions, significant differences (P<.05) between spherical and aspheric IOLs were detected for spatial frequencies of 12 and 18 cycles per degree (cpd) at 2 months and 2 years and 12 cpd at 1 year. Under mesopic conditions, significant differences (P<.05) were detected between spherical and aspheric IOLs for all spatial frequencies at 2 months; all spatial frequencies except 18 cpd at 1 year; and spatial frequencies of 3, 12, and 18 cpd at 2 years. In addition, aspheric IOLs had statistical reductions in total spherical aberration at all follow-up examinations (P<.01). CONCLUSIONS: This study confirms that implantation of a modified aspheric IOL improves functional visual performance at 2 years postoperative. [J Refract Surg. 2009;25:578-590.] doi:10.3928/1081597X-20090610-03
引用
收藏
页码:578 / 590
页数:13
相关论文
共 50 条
  • [31] Contrast and glare sensitivity after implantation of AcrySof® and Human Optics 1CU® intraocular lenses
    Kamppeter, BA
    Sauder, G
    Jonas, JB
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (04) : 458 - 461
  • [32] CONTRAST SENSITIVITY IN MULTIFOCAL INTRAOCULAR LENSES
    RAVALICO, G
    BACCARA, F
    RINALDI, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01): : 22 - 25
  • [33] Optical quality comparison between spherical and aspheric toric intraocular lenses
    Perez-Vives, Carl
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (05) : 699 - 706
  • [34] Comparison of retinal image quality with spherical and customized aspheric intraocular lenses
    Guo, Huanqing
    Goncharov, Alexander V.
    Dainty, Chris
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (04): : 681 - 691
  • [35] Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
    Kurz, Sabine
    Krummenauer, Frank
    Thieme, Hagen
    Dick, H. Burkhard
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 393 - 400
  • [36] Comparative study of aspheric intraocular lenses with negative spherical aberration or no aberration
    Denoyer, Alexandre
    Denoyer, Ludovic
    Halfon, Jeremie
    Majzoub, Samuel
    Pisella, Pierre-Jean
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03): : 496 - 503
  • [37] Theoretical comparison of optical quality with a spherical and two aspheric intraocular lenses
    Kawamorita, Takushi
    Uozato, Hiroshi
    Shimizu, Kimiya
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [38] Clinical Impact of Spherical Aberration on Focal Depth and on Contrast Sensitivity of Different Intraocular Lenses
    Schroeder, A. C.
    Langenbucher, A.
    Seitz, B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] Contrast Sensitivity and Patient Reported Outcomes After Bilateral Implantation of a Bi-Aspheric Hydrophobic Trifocal Diffractive Intraocular Lens
    Tana-Rivero, Pedro
    Orts-Vila, Paz
    Aguilar-Corcoles, Salvador
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 247 - 258
  • [40] Contrast sensitivity in patients with silicone intraocular lenses
    Mantyjarvi, M
    Tuppurainen, K
    OPHTHALMOLOGICA, 1997, 211 (04) : 214 - 218