Preoperative biliary drainage using a fully covered self-expandable metallic stent for pancreatic head cancer: A prospective feasibility study

被引:11
|
作者
Togawa, Osamu [1 ,5 ]
Isayama, Hiroyuki [2 ,3 ]
Kawakami, Hiroshi [6 ]
Nakai, Yousuke [2 ]
Mohri, Dai [2 ]
Hamada, Tsuyoshi [2 ]
Kogure, Hirofumi [2 ]
Kawakubo, Kazumichi [6 ]
Sakamoto, Naoya [6 ]
Koike, Kazuhiko [2 ]
Kita, Hiroto [4 ,5 ]
机构
[1] Univ Tokyo, Kanto Cent Hosp, Mutual Aid Assoc Publ Sch Teachers, Dept Gastroenterol, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[3] Juntendo Univ, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[4] Teikyo Univ, Sch Med, Dept Internal Med, Tokyo, Japan
[5] Saitama Med Univ, Int Med Ctr, Dept Gastroenterol, Saitama, Japan
[6] Hokkaido Univ, Grad Sch Med, Dept Gastroenterol & Hepatol, Sapporo, Hokkaido, Japan
来源
SAUDI JOURNAL OF GASTROENTEROLOGY | 2018年 / 24卷 / 03期
关键词
Pancreatic cancer; preoperative biliary drainage; self-expandable metallic stent; MALIGNANT OBSTRUCTIVE-JAUNDICE; TRANS-HEPATIC DRAINAGE; DECISION-ANALYSIS; RANDOMIZED-TRIAL; PLASTIC STENTS; DECOMPRESSION; PANCREATICODUODENECTOMY; COMPLICATIONS; CHOLECYSTITIS; METAANALYSIS;
D O I
10.4103/sjg.SJG_448_17
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: The role of endoscopic preoperative biliary drainage (PBD) for pancreatic head cancer is controversial because of the high incidence of stent occlusion before surgery. This study was performed to evaluate the feasibility and safety of PBD using a fully covered self-expandable metallic stent (FCSEMS). Patients and Methods: This multicenter prospective study involved 26 patients treated for pancreatic head cancer with distal bile duct obstruction from April 2011 to March 2013. An FCSEMS was endoscopically placed in 24 patients. Among these, 7 patients were diagnosed with unresectable cancer, and 17 underwent surgery at a median of 18 days after FCSEMS placement. The main outcome measure was preoperative and postoperative adverse events. Results: Two adverse events (cholecystitis and insufficient resolution of jaundice) occurred between FCSEMS placement and surgery (12%). Postoperative adverse events occurred in eight patients (47%). The cumulative incidence of stent-related adverse events 4 and 8 weeks after FCSEMS placement among the 24 patients who underwent this procedure were 19%. Conclusions: PBD using an FCSEMS is feasible in patients with resectable pancreatic head cancer. Placement of an FCSEMS can be an alternative PBD technique when surgery without delay is impossible. A larger randomized controlled trial is warranted.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 50 条
  • [21] Safety and Efficacy of a New Fully Covered Self-Expandable Metallic Airway Stent
    Holden, V. K.
    Alape, D.
    Chee, A. C.
    Parikh, M. S.
    Leclair, T.
    Majid, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [22] A fully covered self-expandable metal stent with antimigration features for benign biliary strictures: a prospective, multicenter cohort study
    Walter, Daisy
    Laleman, Wim
    Jansen, Jeroen M.
    de Wit, A. W. M. van Milligen
    Weusten, Bas L.
    van Boeckel, Petra G.
    Hirdes, Meike M.
    Vleggaar, Frank P.
    Siersema, Peter D.
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : 1197 - 1203
  • [23] Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction
    Takahashi, Sho
    Fujisawa, Toshio
    Ushio, Mako
    Fukuma, Taito
    Suzuki, Akinori
    Takasaki, Yusuke
    Ito, Koichi
    Tomishima, Ko
    Ishii, Shigeto
    Isayama, Hiroyuki
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (03) : 408 - 415
  • [24] PREOPERATIVE BILIARY DECOMPRESSION PRECEDING PANCREATICODUODENECTOMY WITH PLASTIC OR SELF-EXPANDABLE METALLIC STENT
    Haapamaki, C.
    Seppanen, H.
    Udd, M.
    Juuti, A.
    Halttunen, J.
    Kiviluoto, T.
    Siren, J.
    Mustonen, H.
    Kylanpaa, L.
    SCANDINAVIAN JOURNAL OF SURGERY, 2015, 104 (02) : 79 - 85
  • [25] Pilot study of a novel, large-bore, fully covered self-expandable metallic stent for unresectable distal biliary malignancies
    Mukai, Tsuyoshi
    Yasuda, Ichiro
    Isayama, Hiroyuki
    Iwashita, Takuji
    Itoi, Takao
    Kawakami, Hiroshi
    Kogure, Hirofumi
    Nakai, Yousuke
    DIGESTIVE ENDOSCOPY, 2016, 28 (06) : 671 - 679
  • [26] Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self-Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study
    Minato, Naoki
    Okuwaki, Kosuke
    Watanabe, Masafumi
    Woo, Jun
    Matsumoto, Takaaki
    Tadehara, Masayoshi
    Kaneko, Toru
    Ishizaki, Junro
    Iwai, Tomohisa
    Imaizumi, Hiroshi
    Kida, Mitsuhiro
    Haradome, Hiroki
    Kusano, Chika
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2025, 40 (02) : 502 - 509
  • [27] Fully covered self-expandable metal biliary stent for hemobilia caused by portal biliopathy
    Goenka, Mahesh Kumar
    Harwani, Yogesh
    Rai, Vijay
    Goenka, Usha
    GASTROINTESTINAL ENDOSCOPY, 2014, 80 (06) : 1175 - 1175
  • [28] Clinical feasibility of a new through-the-scope fully covered esophageal self-expandable metallic stent: An in vivo animal study
    Cheon, Young Koog
    Lee, Tae Yoon
    Sung, In Kyung
    Shim, Chan Sup
    DIGESTIVE ENDOSCOPY, 2014, 26 (01) : 32 - 36
  • [29] Successful removal of a proximally migrated biliary fully covered self-expandable metal stent using a sphincterotome
    Koizumi, Kazuya
    Kimura, Karen
    Jinushi, Ryuhei
    DIGESTIVE ENDOSCOPY, 2024, 36 (03) : 374 - 375
  • [30] Fully Covered Self-expandable Metallic Stents in the Management of Benign Biliary Tract Diseases
    Canena, Jorge
    Liberato, Manuel
    Romao, Carlos
    Horta, David
    Coutinho, Antonio
    Neves, Beatriz
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 : S530 - S531