Evaluation of medium voltage stator bar groundwall insulation under inverter-fed pulses

被引:0
|
作者
Haq, Saeed Ul [1 ]
Jayaram, Shesha H. [1 ]
Cherney, Edward A. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, 200 Univ Ave W, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1109/CEIDP.2006.311970
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this research work, the behavior of medium voltage stator bar groundwall insulation that is subjected to steep-front voltage pulses, at various repetition rates and temperatures, is studied. The test conditions include; pulse voltage amplitudes up to 3.5 kV(p), pulse switching frequencies up to 3 kHz, and in ambient temperatures of 23 and 155 degrees C. During the aging process, the surface temperature is monitored with an infrared camera as a means for determining the locations of the highest temperature and therefore the highest regions of PD activity. Visual observations confirm degradation of the groundwall insulation in the regions of highest temperature and PD measurements show increased activity and reduced PD inception with aging.
引用
收藏
页码:465 / 468
页数:4
相关论文
共 50 条
  • [21] Synthesis of Stator Current Waveform of Inverter-Fed Induction Motor with Broken Bar Conditions
    Sittisrijan, N.
    wangngon, B.
    Ruangsinchaiwanich, S.
    [J]. 2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 3441 - 3445
  • [22] Evaluation stator winding faults severity in inverter-fed induction motors
    Godoy, Wagner Fontes
    da Silva, Ivan Nunes
    Goedtel, Alessandro
    Cunha Palacios, Rodrigo Henrique
    [J]. APPLIED SOFT COMPUTING, 2015, 32 : 420 - 431
  • [23] Evaluation of medium voltage groundwall insulation exposed to high frequency pulse voltages
    Ul Haq, S
    Jayaram, SH
    Cherney, EA
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING CONFERENCE, 2005, : 194 - 197
  • [24] Improved groundwall insulation for VPI'ed high voltage stator coils
    Emery, FT
    Smith, JDB
    Schoch, KF
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 589 - 592
  • [25] Novel insulation aging test system based on continuous high voltage square pulses for inverter-fed traction motors
    Gao, Bo
    Wu, Guangning
    Tong, Laisheng
    Lin, Tongguang
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2008, 29 (01): : 43 - 48
  • [26] The Effect of Impulsive Voltage Rise Time on Insulation Endurance of Inverter-fed Motors
    Wang, Peng
    Cavallini, Andrea
    Montanari, Gian Carlo
    [J]. 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 84 - 87
  • [27] Influence of Current Transducer Transfer Properties on Stator Insulation Condition Monitoring of Inverter-fed Drives
    Zoeller, C.
    Vogelsberger, M. A.
    Fahrner, Walter
    Wolbank, Th. M.
    [J]. 2016 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2016, : 55 - 60
  • [28] Analysis of voltage distribution in stator winding of IGBT PWM inverter-fed induction motors
    Hwang, DH
    Lee, KC
    Jeon, JW
    Kim, YJ
    Kim, MH
    Kim, DH
    [J]. ISIE 2005: PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS 2005, VOLS 1- 4, 2005, : 945 - 950
  • [29] Effect of varistors for overvoltage protection in inverter-fed drives on the voltage distribution in the stator winding
    Rocks, Alexander
    Hinrichsen, Volker
    [J]. CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 624 - 627
  • [30] Detection Method of Inter-Turn Insulation Defects of Inverter-Fed Motors Under Induced Impulse Voltage
    Liu, Xuezhong
    Liu, Ping
    Zhang, Tianlong
    Yuan, Pengfei
    Zhu, Hugh
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2021, 37 (01) : 27 - 39