Investigation on the application of solar chimney for multi-storey buildings

被引:55
|
作者
Punyasompun, Sompop [1 ]
Hirunlabh, Jongjit [1 ]
Khedari, Joseph [2 ]
Zeghmati, Belkacem [3 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Sch Energy Environm & Mat, Div Energy Technol, Inst Sci & Technol Res & Serv,Bldg Sci Res Ctr, Bangkok 10140, Thailand
[2] Kasetsart Univ, Fac Architecture, Div Bldg Technol, Bangkok 10900, Thailand
[3] Univ Perpignan, Grp Mecan Energet, Lab Math & Phys Syst, F-66860 Perpignan, France
关键词
Natural ventilation; Solar chimney; High-rise building; Numerical modeling; Field experiment; PERFORMANCE; VENTILATION;
D O I
10.1016/j.renene.2009.03.032
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents investigation on the use of solar chimney (SC) in high-rise building. To this end, two small scale models of a three storey building were built. The floor dimensions of each storey are 1.2 x 2 x 1 m. Solar chimneys were integrated into the south-faced walls of one unit whereas the other unit served as a reference. Two design configurations were considered including connected and non-connected solar chimney: The first is a tall SC with an inlet opening at each floor and one outlet opening at the third floor. While for the second, an inlet and outlet openings were installed at each floor. Data recorded included room temperature, air gap temperature and velocity of the induced air flow in the solar chimney. First, a comparison between the SC building models and a common model without openings (SC) demonstrated that multi-storey solar chimney is a good alternative. Room temperature of the solar chimney model was lower than the room temperature of the common model, depending on the floor level by up to 5 degrees C. Next comparison between the two SC configurations showed that the best configuration is that with an inlet opening at each floor and one outlet opening at the third floor as temperature difference between room and ambient was the lowest. Reasonable agreement between the experimental data and those derived from our mathematical model developed using electric analogies validated our model. Therefore multi-storey solar chimney is an interesting option and could be applied for hot climate like in Thailand to save energy and environment. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2545 / 2561
页数:17
相关论文
共 50 条
  • [21] Multi-storey prestressed timber buildings in New Zealand
    Department of Timber Design
    不详
    不详
    不详
    Struct Eng Int J Int Assoc Bridge Struct Eng, 2008, 2 (166-173):
  • [22] Hybrid-reinforced rafts for multi-storey buildings
    Haus, Andreas
    BETON- UND STAHLBETONBAU, 2021, 116 : 95 - 96
  • [23] Specifics of Air Distribution in Multi-Storey Apartment Buildings
    Borodinecs, Anatolijs
    Gaujena, Baiba
    ADVANCED CONSTRUCTION 2010, 2010, : 221 - +
  • [24] ARCHITECTURAL DESIGN CRITERIA FOR MULTI-STOREY HOUSING BUILDINGS
    Kuan, Yong
    Ahmad, Yahaya
    OPEN HOUSE INTERNATIONAL, 2016, 41 (01) : 67 - 73
  • [25] Assessment of the adaptivity of multi-storey buildings for the urban area
    Stroetmann, Richard
    Otto, Jens
    Eisele, Johann
    Bleicher, Volkmar
    Wisnewski, Joachim
    Dorn, Charlotte
    Trautmann, Benjamin
    Bauer, Max
    BAUTECHNIK, 2022, 99 (03) : 199 - 212
  • [26] Seismic torsional effects on multi-storey steel buildings
    Ştefănescu, Bogdan Cătălin
    Calotescu, Ileana
    ce/papers, 2021, 4 (2-4) : 1942 - 1948
  • [27] Smoke movement in multi-storey buildings using CUsmoke
    Wang, Yan
    Hadjisophocleous, George
    Zalok, Ehab
    SAFETY SCIENCE, 2013, 52 : 13 - 27
  • [28] A complete timber building system for multi-storey buildings
    Daerga, Per-Anders
    Girhammar, Ulf Arne
    Kallsner, Bo
    CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1164 - 1171
  • [29] DEVELOPMENT OF MULTI-STOREY TIMBER BUILDINGS IN EUROPE AND US
    Kuzman, Manja K.
    Haviarova, Eva
    INCREASING THE USE OF WOOD IN THE GLOBAL BIO-ECONOMY, 2018, : 200 - 206
  • [30] Elastic Spatial Characteristics of Multi-storey Buildings.
    Anastassiadis, Kyriakos
    Annales de l'Institut technique du batiment et des travaux publics, 1985, 38 (435): : 57 - 79